Hand Held Products 600 Cleaning the Wand, Accessories and Options, Item/DescriptionOrder code

Page 20

2.Hold the mouse wand as you would a computer mouse, placing your fingers on each side of the mouse near the front.

3.Lightly pass the mouse wand over either quiet zone (clear area) of the bar code. If the unit does not respond, press POWER.

4.At about the same speed with which you would quickly underline a sentence in this manual, and without interruption, gently pass the mouse wand across the center of the bar code. You do not need to press the mouse on the bar code.

5.Listen for audible tones.

If you hear a long beep tone followed by a short tone, it signifies a good read.

If you hear a long beep and then three short beeps, the unit detects an error in the scanned symbol.

If one of these messages appears, slowly, please!; faster, please!; or more evenly, please!; adjust your scan technique accordingly. If a symbol consistently produces no beeping, it is either fatally out of spec or it is not one of the symbologies programmed on the unit.

If you receive a message about a bad quiet zone, you may have started scanning too close to the first bar. Rescan the symbol, starting a little farther away from the first bar.

6.Practice your scanning technique until you can successfully scan, on the first attempt, each of the test symbols supplied with the verifier.

Cleaning the Wand

Occasionally the scanner tip or window may become partially obstructed by ink, paper fibers, or other particulate deposits (such as wax or varnish). To ensure reliable scanning, you should periodically check and, if necessary, clean the tip with a soft cloth.

Note: Damaged tips for the pen wand should be replaced. Consult your dealer or Hand Held Products’ Customer Service Department for details.

Accessories and Options

Hand Held Products supplies a variety of accessories and options for the Quick Check 600/800 Verifier. The items indicated by an asterisk are supplied with the verifier.

Item/DescriptionOrder code

Charger & Batteries

*Quick Check 600/800 Verifier AC Charger . . . . . . . . . QCAC = 110 VAC QCAC 220B = 220 VAC UK QCAC 220A = 220 VAC Europe

*NiCad Rechargeable batteries (set of four “AA” size) . . . . . . . . . . QCB

1 - 14

Quick Check® 600/800 Series User’s Guide

Image 20
Contents User’s Guide Waste Electrical and Electronic Equipment Information DisclaimerFor European Community Users Table of Contents Reviewing Scan Data Saving and Printing Chapter Customer Support Getting Started About This GuideTerm in manual Term in software SymbolDescription Power or Select or ↑, ↓, ←, →Unpacking the Quick Check 600/800 Verifier Noting the Verifier’s Features Quick Check 600/800 VerifierEAN/UPC Special Features DisplayLEDs ButtonsPorts Specification SpecificationsInstalling the Batteries To charge the batteries To Install the BatteriesCharging the Batteries Turning the Unit On and Off To turn on the unitNo Printer Attached, then refer to .a Quick Check 600/800 Series User’s Guide To calibrate the Quick Check 600/800 Verifier Calibrating the Quick Check 600/800 VerifierTo turn off the unit Properly Scanning With the Unit To scan properly using a pen wandTo scan properly using a mouse wand Item/DescriptionOrder code Cleaning the WandAccessories and Options Documentation Quick Check 600/800 Series User’s Guide Quick Start Guide Review the option settings Print your scan resultsSymbologies Changing the SettingsChanging the Specifications Symbologies Symbology Specifications Symbology Parameters defaults are in boldMagnification Factor Expand U.P.C./EOCheck Options Modes ShownCharacter Font & Tolerances Character Translation Table Code 128, Code 16K, and CodeTo modify the symbology options Wide-to-Narrow RatioFixed Message Length → or SelectIndustry Applications To select an application Changing the Test CriteriaScan Grade Number of Scans DecodabilityISO/IEC grades To change the test criteria To return to the previous menu, press PowerChanging the Scanning Options Beeper Pitch Extended AccuracyDecode Direction To change the scanning optionsParameter Result Lines Changing the Output OptionsDisplay Options Print Options AutoPrint/StoreTo change the display options Scan ProfileTo change the output options Resetting the Default Settings Locking the SettingsTo reset a unit To change the printout optionsUsing a Command Code About Command CodesC./EAN/JAN Enable On or Off Generic Code SelectionsChoosing a Command Code Customized Command CodesTo request a Command Code from Hand Held Products To use a customized Command CodeTo create a customized Command Code Quick Check 600/800 Series User’s Guide Scan Grades Reviewing Scan DataReviewing Scan Results ISO/IEC Symbol Grade Determining the ISO/IEC Symbol Grade Quick Check 600/800 Series User’s Guide To obtain the scan grade and ISO/IEC Symbol grade Reviewing a Scan ExampleQuick Check 600/800 Series User’s Guide LED Display To review data from the last scanAudio Sounds Bar growth LCD bar growth LED lit Tolerance used IndicationReviewing the Dimensional Parameters Errors in Dimensional ParametersParameter Trad’l Parameter ResultTo review the dimensional parameters CalculatingReviewing the Reflectance Parameters Errors in Reflectance Parameters PCSSymbol Contrast, Minimum and Maximum Reflectance To review the reflectance parametersErrors in Format Parameters Reviewing the Format ParametersTo review the format procedures Reviewing MessagesSstr Code Type Test Criteria Name Using Sstr Codes to Review DataSstr Codes Using the Quick Check Verifier as a Reflectometer To quickly review data using Sstr CodesTo return the customized display to the default display To customize the result displayTo use the Quick Check Verifier as a static reflectometer Saving and Printing Saving DataChecking the Print Buffer During Operation To save scan dataPrinting Data To check the print buffer during operationTo clear delete the records stored in the memory, press → To print current dataTo stop printing Deleting Stored DataTo print stored data To delete stored data Interfacing With a ComputerReviewing the Printouts QCP and Qchsp Printouts Using the QCP or Qchsp Printing GuidelinesSwitch Position Function To turn on and off the QCP or Qchsp To set up the QCP or QchspTo install or replace the QCP or Qchsp paper roll To remove the ribbon from the QCP or Qchsp To perform a QCP or Qchsp self-test Troubleshooting the QCP or Qchsp Quick Check 600/800 Series User’s Guide Background Information General Bar Code InformationSymbology Specifications Symbology Industries OrganizationGS1 formerly UCC and EAN Symbology Characteristics Quick Check 600/800 Series User’s Guide Element Symbology Character Set WidthsHow a Bar Code Verifier Works Additional Information Quick Check 600/800 Series User’s Guide Using DataMatch Understanding the DataMatch FeatureDownloading DataMatch Structuring and Loading the Database SYM Identifier CodeDecode To load the database into the verifierQuick Check 600/800 Series User’s Guide Selecting the DataMatch Feature To select DataMatchReviewing DataMatch Results Quick Check 600/800 Series User’s Guide Using a Quick Check 800 Verifier General OperationScanProfile Output Percent Decoded/Scanned ModeReflectance-Based Information Print Results Calculate Decoded/Scanned Change Settings Change Settings Test Criteria #Scans/Symbol nnn Error, Application, and Type Messages Type Display Message Printout MessageDatabase ECV /VCVS Bookland Quick Check 600/800 Series User’s Guide Ccbba Hibcc EAN ITF SCS /ITF EAN SCS Quick Check 600/800 Series User’s Guide Flow Charts Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Sstr Codes Quick Check 600/800 Series User’s Guide Special Codes Quick Check 600/800 Series User’s Guide Unrecognized Symbols Unrecognized SymbolsQuick Check 600/800 Series User’s Guide Troubleshooting To restore the displayCustomer Support To check the software versionLatin America Limited Warranty Quick Check 600/800 Series User’s Guide Page Hand Held Products, Inc