Hand Held Products 800, 600 Resetting the Default Settings, Locking the Settings, To reset a unit

Page 39

5.To change the printout options:

To change the printout options, set the cursor on the asterisk next to Printout Options and then press SELECT. A menu with the printout options selections appears.

To change the printer type, set the cursor on the asterisk next to Printer Type and then press SELECT or until the setting you want, QCP or QCHSP, appears.

To change the printout form, set the cursor on the asterisk next to Printout and then press SELECT or until the setting you want, Long or Short, appears.

To change the AutoPrint and Store setting, set the cursor on the asterisk next to AutoPrint/Store and then press SELECT or until the setting you want, On or Off appears. If you set the AutoPrint and Store setting On, you may want to use it with or without Profile. To change

the Profile settings, set the cursor on the asterisk next to w/Profile?. Press SELECT or until the setting you want, Yes or No, appears.

6.To return to the previous menu, press POWER.

To scan a symbol, set the wand on the symbol’s quiet zone.

Resetting the Default Settings

If you make changes to your Quick Check 600/800 Verifier’s settings, you can easily reset them to the factory installed defaults.

To reset a unit:

1.Scan the special “Reset All Options” code located in Chapter 12, Special Codes. The unit reinstalls the factory default settings.

2.Recalibrate the unit.

Refer to Chapter 2, Quick Start Guide for instructions.

Locking the Settings

After you set all the options (specifications, test criteria, scanning options and output options) on the Quick Check 600/800 Verifier, you can “lock” the unit so that you or others cannot accidentally change the settings during routine use. If you lock the unit, you must unlock it to change any settings. Use the Special Codes provided in the back of this manual to lock and unlock the unit. The verifier is shipped in the unlocked mode.

To lock the unit:

1.Customize your verifier by setting all the options the way you want them.

2.Scan the “Lock Specs and Tests” Special Code.

The unit is now locked. You cannot change any option settings unless you unlock the unit or scan "Reset All Options" which sets the unit to its factory defaults.

Quick Check® 600/800 Series User’s Guide

3 - 15

Image 39
Contents User’s Guide Disclaimer For European Community UsersWaste Electrical and Electronic Equipment Information Table of Contents Reviewing Scan Data Saving and Printing Chapter Customer Support About This Guide Getting StartedSymbolDescription Power or Select or ↑, ↓, ←, → Unpacking the Quick Check 600/800 VerifierTerm in manual Term in software Quick Check 600/800 Verifier Noting the Verifier’s FeaturesEAN/UPC Buttons Special FeaturesDisplay LEDsPorts Specifications Installing the BatteriesSpecification To Install the Batteries Charging the BatteriesTo charge the batteries To turn on the unit Turning the Unit On and OffNo Printer Attached, then refer to .a Quick Check 600/800 Series User’s Guide Calibrating the Quick Check 600/800 Verifier To turn off the unitTo calibrate the Quick Check 600/800 Verifier To scan properly using a pen wand To scan properly using a mouse wandProperly Scanning With the Unit Cleaning the Wand Accessories and OptionsItem/DescriptionOrder code Documentation Quick Check 600/800 Series User’s Guide Quick Start Guide Print your scan results Review the option settingsChanging the Settings Changing the SpecificationsSymbologies Symbologies Symbology Parameters defaults are in bold Symbology SpecificationsModes Shown Magnification FactorExpand U.P.C./EO Check OptionsCharacter Translation Table Code 128, Code 16K, and Code Character Font & Tolerances→ or Select To modify the symbology optionsWide-to-Narrow Ratio Fixed Message LengthIndustry Applications Changing the Test Criteria Scan GradeTo select an application Decodability ISO/IEC gradesNumber of Scans To return to the previous menu, press Power Changing the Scanning OptionsTo change the test criteria To change the scanning options Beeper PitchExtended Accuracy Decode DirectionChanging the Output Options Display OptionsParameter Result Lines AutoPrint/Store Print OptionsScan Profile To change the output optionsTo change the display options To change the printout options Resetting the Default SettingsLocking the Settings To reset a unitAbout Command Codes Using a Command CodeGeneric Code Selections C./EAN/JAN Enable On or OffCustomized Command Codes Choosing a Command CodeTo use a customized Command Code To create a customized Command CodeTo request a Command Code from Hand Held Products Quick Check 600/800 Series User’s Guide Reviewing Scan Data Reviewing Scan ResultsScan Grades ISO/IEC Symbol Grade Determining the ISO/IEC Symbol Grade Quick Check 600/800 Series User’s Guide Reviewing a Scan Example To obtain the scan grade and ISO/IEC Symbol gradeQuick Check 600/800 Series User’s Guide To review data from the last scan LED DisplayBar growth LCD bar growth LED lit Tolerance used Indication Audio SoundsParameter Result Reviewing the Dimensional ParametersErrors in Dimensional Parameters Parameter Trad’lCalculating To review the dimensional parametersReviewing the Reflectance Parameters PCS Errors in Reflectance ParametersTo review the reflectance parameters Symbol Contrast, Minimum and Maximum ReflectanceReviewing the Format Parameters Errors in Format ParametersReviewing Messages To review the format proceduresUsing Sstr Codes to Review Data Sstr CodesSstr Code Type Test Criteria Name To customize the result display Using the Quick Check Verifier as a ReflectometerTo quickly review data using Sstr Codes To return the customized display to the default displayTo use the Quick Check Verifier as a static reflectometer To save scan data Saving and PrintingSaving Data Checking the Print Buffer During OperationTo print current data Printing DataTo check the print buffer during operation To clear delete the records stored in the memory, press →Deleting Stored Data To print stored dataTo stop printing Interfacing With a Computer Reviewing the PrintoutsTo delete stored data QCP and Qchsp Printouts Printing Guidelines Using the QCP or QchspSwitch Position Function To set up the QCP or Qchsp To install or replace the QCP or Qchsp paper rollTo turn on and off the QCP or Qchsp To remove the ribbon from the QCP or Qchsp To perform a QCP or Qchsp self-test Troubleshooting the QCP or Qchsp Quick Check 600/800 Series User’s Guide General Bar Code Information Background InformationSymbology Industries Organization Symbology SpecificationsGS1 formerly UCC and EAN Symbology Characteristics Quick Check 600/800 Series User’s Guide Symbology Character Set Widths How a Bar Code Verifier WorksElement Additional Information Quick Check 600/800 Series User’s Guide SYM Identifier Code Using DataMatchUnderstanding the DataMatch Feature Downloading DataMatch Structuring and Loading the DatabaseTo load the database into the verifier DecodeQuick Check 600/800 Series User’s Guide To select DataMatch Selecting the DataMatch FeatureReviewing DataMatch Results Quick Check 600/800 Series User’s Guide General Operation Using a Quick Check 800 VerifierPercent Decoded/Scanned Mode Reflectance-Based InformationScanProfile Output Print Results Calculate Decoded/Scanned Change Settings Change Settings Test Criteria #Scans/Symbol nnn Type Display Message Printout Message Error, Application, and Type MessagesDatabase ECV /VCVS Bookland Quick Check 600/800 Series User’s Guide Ccbba Hibcc EAN ITF SCS /ITF EAN SCS Quick Check 600/800 Series User’s Guide Flow Charts Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Sstr Codes Quick Check 600/800 Series User’s Guide Special Codes Quick Check 600/800 Series User’s Guide Unrecognized Symbols Unrecognized SymbolsQuick Check 600/800 Series User’s Guide To check the software version TroubleshootingTo restore the display Customer SupportLatin America Limited Warranty Quick Check 600/800 Series User’s Guide Page Hand Held Products, Inc