Hand Held Products 800, 600 manual LED Display, To review data from the last scan

Page 51

Note: If you set the Test Criteria Passing parameter to an ISO/IEC grade and you set the #Scans/Symbol parameter to 1, the scan grade is the same as the ISO/IEC symbol grade.

The first line of the symbol grade display provides the symbol or application name, the same as the first line of the scan grade display.

The second line of this display indicates this data is a final symbol grade, that is, it is an average of the scan grades you have obtained.

The third line provides a variety of information. The first of the three terms refers to the current average grade the symbol received. The subsequent terms, for example 06/660, refer to the wand aperture and the wavelength. These values are used to determine the symbol grade. Refer to "If the unit was set to use the database feature before being turned off, the bottom line shows the term DATABASE." on page 1-9for additional information.

The last line lets you check your status in relation to the

symbol grade. The first value in this line tells you how many scan grades were used to calculate the displayed symbol grade. The second value tells you the number of scan grades required to calculate the final symbol grade.

The large letter or number on the right of the display is the symbol grade. The verifier can display the symbol grade either as letter (A, B, C, D, F) or as a number (4, 3, 2, 1, 0), depending on how you set the Test Criteria Grades parameter.

5.To obtain the final symbol grade, you must satisfy the #Scans/Symbol setting. Repeat steps 2 through 4, scanning the same bar symbol at different paths within the symbol.

When you satisfy the #Scans/Symbol setting, the final

symbol grade display appears.

To review the scan grade display, press . Press to return to the final symbol grade display.

The types of data provided in the final symbol grade display are the same as those in the symbol grade display.

To review data from the last scan:

1.If the Quick Check Verifier is turned off, turn it on. The opening display appears.

2.Press .

The results from the last scan appear.

LED Display

The light-emitting diodes (LEDs) can indicate either bar growth and shrinkage based on traditional test criteria or a pass/fail grade result based on ISO/IEC grade criteria. You set the type of test criteria. Refer to "Changing the Test Criteria" on page 3-8for additional information.

Quick Check® 600/800 Series User’s Guide

4 - 7

Image 51
Contents User’s Guide Disclaimer For European Community UsersWaste Electrical and Electronic Equipment Information Table of Contents Reviewing Scan Data Saving and Printing Chapter Customer Support About This Guide Getting StartedSymbolDescription Power or Select or ↑, ↓, ←, → Unpacking the Quick Check 600/800 VerifierTerm in manual Term in software Quick Check 600/800 Verifier Noting the Verifier’s FeaturesEAN/UPC Buttons Special FeaturesDisplay LEDsPorts Specifications Installing the BatteriesSpecification To Install the Batteries Charging the BatteriesTo charge the batteries To turn on the unit Turning the Unit On and OffNo Printer Attached, then refer to .a Quick Check 600/800 Series User’s Guide Calibrating the Quick Check 600/800 Verifier To turn off the unitTo calibrate the Quick Check 600/800 Verifier To scan properly using a pen wand To scan properly using a mouse wandProperly Scanning With the Unit Cleaning the Wand Accessories and OptionsItem/DescriptionOrder code Documentation Quick Check 600/800 Series User’s Guide Quick Start Guide Print your scan results Review the option settingsChanging the Settings Changing the SpecificationsSymbologies Symbologies Symbology Parameters defaults are in bold Symbology SpecificationsModes Shown Magnification FactorExpand U.P.C./EO Check OptionsCharacter Translation Table Code 128, Code 16K, and Code Character Font & Tolerances→ or Select To modify the symbology optionsWide-to-Narrow Ratio Fixed Message LengthIndustry Applications Changing the Test Criteria Scan GradeTo select an application Decodability ISO/IEC gradesNumber of Scans To return to the previous menu, press Power Changing the Scanning OptionsTo change the test criteria To change the scanning options Beeper PitchExtended Accuracy Decode DirectionChanging the Output Options Display OptionsParameter Result Lines AutoPrint/Store Print OptionsScan Profile To change the output optionsTo change the display options To change the printout options Resetting the Default SettingsLocking the Settings To reset a unitAbout Command Codes Using a Command CodeGeneric Code Selections C./EAN/JAN Enable On or OffCustomized Command Codes Choosing a Command CodeTo use a customized Command Code To create a customized Command CodeTo request a Command Code from Hand Held Products Quick Check 600/800 Series User’s Guide Reviewing Scan Data Reviewing Scan ResultsScan Grades ISO/IEC Symbol Grade Determining the ISO/IEC Symbol Grade Quick Check 600/800 Series User’s Guide Reviewing a Scan Example To obtain the scan grade and ISO/IEC Symbol gradeQuick Check 600/800 Series User’s Guide To review data from the last scan LED DisplayBar growth LCD bar growth LED lit Tolerance used Indication Audio SoundsParameter Result Reviewing the Dimensional ParametersErrors in Dimensional Parameters Parameter Trad’lCalculating To review the dimensional parametersReviewing the Reflectance Parameters PCS Errors in Reflectance ParametersTo review the reflectance parameters Symbol Contrast, Minimum and Maximum ReflectanceReviewing the Format Parameters Errors in Format ParametersReviewing Messages To review the format proceduresUsing Sstr Codes to Review Data Sstr CodesSstr Code Type Test Criteria Name To customize the result display Using the Quick Check Verifier as a ReflectometerTo quickly review data using Sstr Codes To return the customized display to the default displayTo use the Quick Check Verifier as a static reflectometer To save scan data Saving and PrintingSaving Data Checking the Print Buffer During OperationTo print current data Printing DataTo check the print buffer during operation To clear delete the records stored in the memory, press →Deleting Stored Data To print stored dataTo stop printing Interfacing With a Computer Reviewing the PrintoutsTo delete stored data QCP and Qchsp Printouts Printing Guidelines Using the QCP or QchspSwitch Position Function To set up the QCP or Qchsp To install or replace the QCP or Qchsp paper rollTo turn on and off the QCP or Qchsp To remove the ribbon from the QCP or Qchsp To perform a QCP or Qchsp self-test Troubleshooting the QCP or Qchsp Quick Check 600/800 Series User’s Guide General Bar Code Information Background InformationSymbology Industries Organization Symbology SpecificationsGS1 formerly UCC and EAN Symbology Characteristics Quick Check 600/800 Series User’s Guide Symbology Character Set Widths How a Bar Code Verifier WorksElement Additional Information Quick Check 600/800 Series User’s Guide SYM Identifier Code Using DataMatchUnderstanding the DataMatch Feature Downloading DataMatch Structuring and Loading the DatabaseTo load the database into the verifier DecodeQuick Check 600/800 Series User’s Guide To select DataMatch Selecting the DataMatch FeatureReviewing DataMatch Results Quick Check 600/800 Series User’s Guide General Operation Using a Quick Check 800 VerifierPercent Decoded/Scanned Mode Reflectance-Based InformationScanProfile Output Print Results Calculate Decoded/Scanned Change Settings Change Settings Test Criteria #Scans/Symbol nnn Type Display Message Printout Message Error, Application, and Type MessagesDatabase ECV /VCVS Bookland Quick Check 600/800 Series User’s Guide Ccbba Hibcc EAN ITF SCS /ITF EAN SCS Quick Check 600/800 Series User’s Guide Flow Charts Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Sstr Codes Quick Check 600/800 Series User’s Guide Special Codes Quick Check 600/800 Series User’s Guide Unrecognized Symbols Unrecognized SymbolsQuick Check 600/800 Series User’s Guide To check the software version TroubleshootingTo restore the display Customer SupportLatin America Limited Warranty Quick Check 600/800 Series User’s Guide Page Hand Held Products, Inc