Hand Held Products 600, 800 manual To use the Quick Check Verifier as a static reflectometer

Page 62

When using the reflectance mode, the reflectance “seen” by the unit is continuously shown on the verifier’s display as both a two-digit reflectance percentage (from 0% to 99%) and on a graphic bar graph (gas gauge). For meaningful and consistent static reflectance values, you must calibrate the unit and hold the wand at the proper scan angle with its “foot” just touching the symbol. For information on proper scan technique and calibration, see Chapter 2, Quick Start Guide.

To use the Quick Check Verifier as a static reflectometer:

1.Recalibrate the Quick Check Verifier if the calibration has not been per- formed recently.

2.Press SELECT to display the menu with the term Print Results on top.

3.Press to move the cursor next to Reflectom’r.

4.Press SELECT.

The display changes to show the percent reflectance in large letters on the left of the display. The term Reflectance appears below the reading and a bar graph appears on the right of the display.

4 - 18

Quick Check® 600/800 Series User’s Guide

Image 62
Contents User’s Guide Waste Electrical and Electronic Equipment Information DisclaimerFor European Community Users Table of Contents Reviewing Scan Data Saving and Printing Chapter Customer Support Getting Started About This GuideTerm in manual Term in software SymbolDescription Power or Select or ↑, ↓, ←, →Unpacking the Quick Check 600/800 Verifier Noting the Verifier’s Features Quick Check 600/800 VerifierEAN/UPC LEDs Special FeaturesDisplay ButtonsPorts Specification SpecificationsInstalling the Batteries To charge the batteries To Install the BatteriesCharging the Batteries Turning the Unit On and Off To turn on the unitNo Printer Attached, then refer to .a Quick Check 600/800 Series User’s Guide To calibrate the Quick Check 600/800 Verifier Calibrating the Quick Check 600/800 VerifierTo turn off the unit Properly Scanning With the Unit To scan properly using a pen wandTo scan properly using a mouse wand Item/DescriptionOrder code Cleaning the WandAccessories and Options Documentation Quick Check 600/800 Series User’s Guide Quick Start Guide Review the option settings Print your scan resultsSymbologies Changing the SettingsChanging the Specifications Symbologies Symbology Specifications Symbology Parameters defaults are in boldCheck Options Magnification FactorExpand U.P.C./EO Modes ShownCharacter Font & Tolerances Character Translation Table Code 128, Code 16K, and CodeFixed Message Length To modify the symbology optionsWide-to-Narrow Ratio → or SelectIndustry Applications To select an application Changing the Test CriteriaScan Grade Number of Scans DecodabilityISO/IEC grades To change the test criteria To return to the previous menu, press PowerChanging the Scanning Options Decode Direction Beeper PitchExtended Accuracy To change the scanning optionsParameter Result Lines Changing the Output OptionsDisplay Options Print Options AutoPrint/StoreTo change the display options Scan ProfileTo change the output options To reset a unit Resetting the Default SettingsLocking the Settings To change the printout optionsUsing a Command Code About Command CodesC./EAN/JAN Enable On or Off Generic Code SelectionsChoosing a Command Code Customized Command CodesTo request a Command Code from Hand Held Products To use a customized Command CodeTo create a customized Command Code Quick Check 600/800 Series User’s Guide Scan Grades Reviewing Scan DataReviewing Scan Results ISO/IEC Symbol Grade Determining the ISO/IEC Symbol Grade Quick Check 600/800 Series User’s Guide To obtain the scan grade and ISO/IEC Symbol grade Reviewing a Scan ExampleQuick Check 600/800 Series User’s Guide LED Display To review data from the last scanAudio Sounds Bar growth LCD bar growth LED lit Tolerance used IndicationParameter Trad’l Reviewing the Dimensional ParametersErrors in Dimensional Parameters Parameter ResultTo review the dimensional parameters CalculatingReviewing the Reflectance Parameters Errors in Reflectance Parameters PCSSymbol Contrast, Minimum and Maximum Reflectance To review the reflectance parametersErrors in Format Parameters Reviewing the Format ParametersTo review the format procedures Reviewing MessagesSstr Code Type Test Criteria Name Using Sstr Codes to Review DataSstr Codes To return the customized display to the default display Using the Quick Check Verifier as a ReflectometerTo quickly review data using Sstr Codes To customize the result displayTo use the Quick Check Verifier as a static reflectometer Checking the Print Buffer During Operation Saving and PrintingSaving Data To save scan dataTo clear delete the records stored in the memory, press → Printing DataTo check the print buffer during operation To print current dataTo stop printing Deleting Stored DataTo print stored data To delete stored data Interfacing With a ComputerReviewing the Printouts QCP and Qchsp Printouts Using the QCP or Qchsp Printing GuidelinesSwitch Position Function To turn on and off the QCP or Qchsp To set up the QCP or QchspTo install or replace the QCP or Qchsp paper roll To remove the ribbon from the QCP or Qchsp To perform a QCP or Qchsp self-test Troubleshooting the QCP or Qchsp Quick Check 600/800 Series User’s Guide Background Information General Bar Code InformationSymbology Specifications Symbology Industries OrganizationGS1 formerly UCC and EAN Symbology Characteristics Quick Check 600/800 Series User’s Guide Element Symbology Character Set WidthsHow a Bar Code Verifier Works Additional Information Quick Check 600/800 Series User’s Guide Downloading DataMatch Structuring and Loading the Database Using DataMatchUnderstanding the DataMatch Feature SYM Identifier CodeDecode To load the database into the verifierQuick Check 600/800 Series User’s Guide Selecting the DataMatch Feature To select DataMatchReviewing DataMatch Results Quick Check 600/800 Series User’s Guide Using a Quick Check 800 Verifier General OperationScanProfile Output Percent Decoded/Scanned ModeReflectance-Based Information Print Results Calculate Decoded/Scanned Change Settings Change Settings Test Criteria #Scans/Symbol nnn Error, Application, and Type Messages Type Display Message Printout MessageDatabase ECV /VCVS Bookland Quick Check 600/800 Series User’s Guide Ccbba Hibcc EAN ITF SCS /ITF EAN SCS Quick Check 600/800 Series User’s Guide Flow Charts Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Quick Check 600/800 Series User’s Guide Sstr Codes Quick Check 600/800 Series User’s Guide Special Codes Quick Check 600/800 Series User’s Guide Unrecognized Symbols Unrecognized SymbolsQuick Check 600/800 Series User’s Guide Customer Support TroubleshootingTo restore the display To check the software versionLatin America Limited Warranty Quick Check 600/800 Series User’s Guide Page Hand Held Products, Inc