Ositech comm 614006-001 manual Thin Ethernet Network Characteristics

Page 18

Section Two

Thin Ethernet Network Characteristics

Characteristics

Standard Length

Extended Length

 

Segment

Segment

 

 

 

Standard

IEEE 802.3

IEEE 802.3

 

10Base2

10Base2

 

 

 

Data Rate

10 Mbits

10 Mbits

 

per second

per second

 

 

 

Segment Length

185m (607')

300m (984’)

 

 

 

Maximum number

3 coax, plus 2

3 coax; no repeater

of segments

repeater links

links

between nodes

 

 

 

 

 

Maximum number

4 when using 2

2

of repeaters

repeater links

 

between nodes

 

 

 

 

 

Network Span

925m (3035')

900m (2953’)

 

 

 

Maximum number

30

100

of nodes per

 

 

segment

 

 

 

 

 

Maximum number

1024

1024

of nodes per

 

 

network

 

 

 

 

 

Minimum space

0.5m (1.64'/20")

0.5m (1.64'/20")

between nodes

 

 

 

 

 

Cable type

RG58 A/U or

RG58 A/U or

 

C/U, 50 ohm

C/U, 50 ohm

 

 

 

2 - 10

Trumpcard Ethernet LAN

Image 18
Contents Trumpcard Ethernet LAN User’s Guide and ReferenceHow To Contact Us CopyrightPreface FCC Notice Contents Appendices Introduction Section OneTrumpcard Ethernet LAN Hardware Installation Preparing for InstallationSection Two Installing the Trumpcard Ethernet LAN Connecting to 10BaseT Twisted Pair Networks Media Access Module 10BaseT Network Connection Interface Cabling and Pinout Twisted Pair Network Characteristics ConcentratorsConnecting to 10Base2 Thin Ethernet Networks Thin Coax Ethernet Segment Meter segments unless all LAN adapters and repeaters Thin Ethernet Network Characteristics Characteristics Standard Length Extended Length SegmentMedia Access Module LED Indicators Activity LED REDLink LED Green Section Two Operation Section ThreeSocket Services and Card Services Multi-Function ConfigurationNetwork Software Installation Banyan Vines\DOS\OTCETH.DOS \DOSDEVICE=C\DECNET\OTCETH.DOS FTP Software LanWatchDEVICE=C\DECNET\PROTMAN.SYS /IC\DECNET Call \DECNET\STARTNETIBM LAN Server Operation IBM LAN Support Program \LSP\NETBIND Microsoft LAN Manager Microsoft Windows for Workgroups\LANMAN\NETBIND \WFW\311 PATH=C\NOVELL\NET.CFG OSI$OTCETHCD \NOVELL DEVICE=C\WINDOWS\IFSHLP.SYS\WINDOWS\NETSTART LSLMicrosoft Windows NT NetworkMicrosoft Workgroup Connection for DOS \DOS\NET StartPRIORITY=MS$NETBEUI MS$OTCETH$NIC Ndis Generic BINDINGS=MS$OTCETH$NIC LANABASE=0Novell Netware for DOS PathNetware Netx Novell Netware for OS/2 \NETWARE\OS2\OTCETH.SYSNovell Unixware Dlpi Driver Accompanying the PC Card for more details SCO Unix LLI Driver Init Single User Mode Appendices Section FourAppendix a ODI Keywords Frame frame typeMedia media type Port I/O port INT interrupt levelMEM memory location Node Address nnnnnnnnnnnnLook Ahead Size look ahead value Protocol named protocol protocol id frame typeSocket socket number Frame ETHERNET802.3 Media 10BASET Exclusive Dislink INTAppendix B Ndis Keywords MEDIA= media typeMEM= memory location NETADDRESS= ‘nnnnnnnnnnnn’ INTERRUPT= interrupt levelIOBASE= I/O port SOCKET= socket numberPROTOCOL.INI Example DRIVERNAME=STACK$ BINDINGS=OSITECHNIFAppendix C Messages Failed to register with Multi-Function ManagerOnly supported on Pcmcia 2.x or higher Socket/Card Services Failed to register with Card ServicesUnable to configure Trumpcard Pcmcia adapter not foundHardware not responding Expected Tuple not foundMust be an AT .286 or higher system No Media Cable ConnectedODI Specific Error Messages Section Four