Operation
3.At the ‘Current Configuration’ screen go to the box ‘Selections for Adapter’ and select ‘Ositech Trumpcard’.
4.Press [F4] – to install the IBM LSP and the Ositech Trumpcard NDIS driver.
End of Installation.
The following are examples of possible CONFIG.SYS file setups. These lines would be present in the CONFIG.SYS file.
For one NDIS adapter with both IEEE 802.2 and NETBIOS support, the sequence is as follows:
DEVICE=C:\LSP\PROTMAN.DOS /I:\LSP
DEVICE=C:\LSP\OTCETH.DOS
DEVICE=C:\LSP\DXMA0MOD.SYS 001
DEVICE=C:\LSP\DXME0MOD.SYS
DEVICE=C:\LSP\DXMT0MOD.SYS O=N
For one NDIS adapter with only NETBIOS support, the sequence is as follows:
DEVICE=C:\LSP\PROTMAN.DOS /I:\LSP
DEVICE=C:\LSP\OTCETH.DOS
DEVICE=C:\LSP\DXMA0MOD.SYS.001
DEVICE=C:\LSP\DXMJ0MOD.SYS
The following is an example of a possible PROTOCOL.INI file setup
[PROTMAN_MOD]
DRIVERNAME = PROTMAN$
[DXME0_MOD]
DRIVERNAME = DXME0$ BINDINGS = OSITECH_MOD
[OSITECH_MOD]
DRIVERNAME = OTCETH$
Also in your AUTOEXEC.BAT file the following line should have been added:
C:\LSP\NETBIND
Note: | Keyword specifications associated with the NDIS driver are explained |
| in Appendix B, Error Messages in Appendix C. |
User’s Guide and Reference | 3 - 9 |