Tandberg Data Tandberg LTO2 manual Usage Precautions, General Precautions

Page 51

4.4 Handling Precautions

This section describes precautions to take when handling the data cartridge.

4.4.1 Usage Precautions

Before use

-Open the cartridge door and check that the reader pin is locked.

-Do not use a data cartridge that is damaged, misshapen, or bent.

-When using a data cartridge that has been stored under conditions other than the operation temperature and humidity conditions of the Autoloader, bring the cartridge into the environment in which it will be used for a period at least as long as the time that it was exposed to under conditions outside the operation temperature and humidity conditions (i.e.24 hours maximum) and then use. When the temperature difference is great between the storage and operation locations at this time, do not move the cartridge at once, rather, take care so that the temperature change is in the order of 10°C per hour and allow the data cartridge to adapt to the temperature of the operation location.

When loading to magazine and fixed slots

-Please insert the data cartridge securely. (See Chapter 3 for details.) Firmly close the protective case from which the data cartridge was removed and store it in a clean place

After use

-Be sure to return the used cartridge to the protective case and store it in a dust-free place The cartridge can be stored either horizontally or vertically.

Disposal Method

-When disposing the cartridge, please follow the national and municipal guidelines for disposal.

4.4.2 General Precautions

Do not touch the tape medium (i.e. the magnetic surface).

Do not bring the cartridge close to objects that produce a magnetic field.

Do not place the cartridge where it will be exposed to direct sunlight or near heaters.

Do not subject the cartridge to strong shocks.

Avoid handling the cartridge while eating and drinking or smoking. Also be careful not to allow the cartridge to come into contact with thinners, alcohol, beverages

Be sure to return the cartridge to the case after use.

Insert the cartridge into the magazine carefully.

The data cartridge is sensitive to dirt and dust.

-35 -

Image 51
Contents Tandberg LTO2 Autoloader Trademarks FCC Class B NoticeDescription example in this manual Safety DescriptionsMandatory action Prohibited actionGeneral Cautions Safety CautionsDo not apply starburst wiring Do not lift the device alone Do not cover the air inletDo not disassemble, repair or modify by yourself Vii Figure Ⅰ Warning Label ① Revision History Contents Chapter Daily Maintenance Chapter TroubleshootingChapter Cartridges Introduction Organization of this manual Symbols used in this manual Symbols used in this manualTip Overview of the Tandberg LTO2 Autoloader Tandberg LTO2 AutoloaderFront Panel of the Tandberg LTO2 Autoloader Names and Functions of the Parts・ Enter key Rear Panel of the Tandberg LTO2 Autoloader Liquid Crystal Display LCD Liquid Crystal DisplayCartridges Handling PrecautionsTransfer or Disposal of the Device Main UnitContents of the Carton Setup Preparation Before UseTransporter Locking Screw Instruction TAG Storing the Transporter Locking Screw for later use Scsi Cable ConnectionsAC Power Cable Connection AC Power Cable ConnectionAttaching and removing a Filter Element Attaching and removing the Filter ElementScsi ID Setting Switching on the Power Switch and the Power-On SequenceStart and Shutdown of the System Removal of the Magazine OperationLoading the Magazine Loading the MagazineLoading to Magazine Loading the CartridgeFor using the Tandberg LTO2 Autoloader w/BCRs optional Loading to the Fixed SlotsOperation Examples For using the Tandberg LTO2 Autoloader w/BCR Removal from and Insertion to the Magazine Removal and Insertion of the CartridgesDisplay Eject Slot? Removal from and Insertion to the Fixed SlotsSlot Logical Numbers Organization of the Front Panel SwitchesFunctions of the Switches Operation of the Panel KeysPanel Operation Procedure Display Frm Slt 1? Menu Tree 1 Main Menu Menu CommandsRetry Mode Checking the Scsi ID Setting the Scsi IDOperation Example Changing the Scsi IDTip Display Drv. ID 0? Using the Emergency Release Key Using the Emergency Release KeyCartridges CartridgesData Cartridge Cleaning CartridgeSetting the Write-protect Switch Write-Protect SwitchBar Code Label Using Bar Code Labels PrecautionsGeneral Precautions Usage PrecautionsService Life Standards for Prohibition of UseStorage of Data Cartridges Daily Maintenance CleaningCleaning of the Drive Head Manually Cleaning of the Drive Head Cleaning the Roller inside of the transporter Default CLNROL-function setting EnableChecking the CLNROL- function Setting the CLNROL- function Disable Changing the RtyCnt value RtyCnt value in the CLNROL-functionOperation Example Tip Execution timing of the cleaning Cleaning of the RollerTools and Parts Setting Maintenance mode Cleaning the Roller Setting Cleaning modeShows the upper Roller after cleaning Tip 12 shows the upper Roller after cleaning Operation Cleaning of the interior Cleaning of the Main UnitCleaning of the exterior Cleaning of the fixed slotsCleaning of the cartridge Cleaning of the magazineMovement and Shipping of the Autoloader Phenomenon Recovery Procedure Power Supply TroubleshootingConnections Phenomenon Recovery Procedure Cartridge OperationPhenomenon Recovery Procedure Autoloader Performance CleaningOthers Recovery Procedure P move system initialization Exceeding the recommended operation Other Matters to Check When Requesting MaintenanceAutoloader Main Unit Appendix a SpecificationsLTO2 Data Cartridge TD P/N LTO1 Data Cartridge TD P/N Universal cleaning cartridge TD P/NAppendix B Optional Items and Supplies Optional ItemsSupplies CMer Error Code Appendix C Error CodeErr ×××× Messages Related to the Drive Interface MessagesMessage Description Panel Operation and Other MessagesTandberg Data ASA Kjelsasveien 161 N-411 Oslo Norway Tandberg LTO2 Autoloader Installation and User’s Manual