LTO2 Data Cartridge (TD P/N: 432744)

LTO1 Data Cartridge (TD P/N: 432630-1)

Before you use a data cartridge, acclimatize it to the operating environment for a time equal to the time that it was out of the operating environment, up to a maximum of 24 hours.

The best storage container for the data cartridge is the original shipping container.

When you ship a data cartridge, place it in a sealed, moisture-proof bag to protect it from moisture, contaminants, and physical damage. Ship the cartridge in a shipping container that has enough packing material to cushion the data cartridge and prevent it from moving within the container.

Capacity per cartridge

200 GB (with 2:1 compression400 GB)

 

100 GB (with 2:1 compression200 GB)

Environmental conditions

 

[Operating]

 

Temperature

: 10 - 45ºC (50ºF - 113ºF)

Relative humidity

: 10 - 80%RH (non-condensing)

Wet bulb temperature

: 26ºC maximum (79ºF)

[Storage*8]

 

Temperature

: 16 - 32ºC (60ºF - 90ºF)

Relative humidity

: 20 - 80%RH (non-condensing)

Wet bulb temperature

: 26ºC maximum (79ºF)

*7 with Bar Code Label

 

*8 Operational storage

 

Universal cleaning cartridge (TD P/N: 432631)

This cleaning cartridge is valid for 50 uses.

Environmental conditions are the same as for the data cartridge

- 62 -

Image 78
Contents Tandberg LTO2 Autoloader FCC Class B Notice TrademarksSafety Descriptions Description example in this manualProhibited action Mandatory actionSafety Cautions General CautionsDo not apply starburst wiring Do not cover the air inlet Do not lift the device aloneDo not disassemble, repair or modify by yourself Vii Figure Ⅰ Warning Label ① Revision History Contents Chapter Daily Maintenance Chapter TroubleshootingChapter Cartridges Introduction Organization of this manual Symbols used in this manual Symbols used in this manualTip Tandberg LTO2 Autoloader Overview of the Tandberg LTO2 AutoloaderNames and Functions of the Parts Front Panel of the Tandberg LTO2 Autoloader・ Enter key Rear Panel of the Tandberg LTO2 Autoloader Liquid Crystal Display Liquid Crystal Display LCDMain Unit Handling PrecautionsTransfer or Disposal of the Device CartridgesContents of the Carton Setup Preparation Before UseTransporter Locking Screw Instruction TAG Scsi Cable Connections Storing the Transporter Locking Screw for later useAC Power Cable Connection AC Power Cable ConnectionAttaching and removing the Filter Element Attaching and removing a Filter ElementSwitching on the Power Switch and the Power-On Sequence Scsi ID SettingStart and Shutdown of the System Operation Removal of the MagazineLoading the Magazine Loading the MagazineLoading the Cartridge Loading to MagazineFor using the Tandberg LTO2 Autoloader w/BCRs optional Loading to the Fixed SlotsOperation Examples For using the Tandberg LTO2 Autoloader w/BCR Removal and Insertion of the Cartridges Removal from and Insertion to the MagazineRemoval from and Insertion to the Fixed Slots Display Eject Slot?Operation of the Panel Keys Organization of the Front Panel SwitchesFunctions of the Switches Slot Logical NumbersPanel Operation Procedure Display Frm Slt 1? Menu Commands Menu Tree 1 Main MenuRetry Mode Setting the Scsi ID Checking the Scsi IDChanging the Scsi ID Operation ExampleTip Display Drv. ID 0? Using the Emergency Release Key Using the Emergency Release KeyCartridges CartridgesCleaning Cartridge Data CartridgeWrite-Protect Switch Setting the Write-protect SwitchUsing Bar Code Labels Precautions Bar Code LabelUsage Precautions General PrecautionsService Life Standards for Prohibition of UseStorage of Data Cartridges Daily Maintenance CleaningCleaning of the Drive Head Manually Cleaning of the Drive Head Cleaning the Roller inside of the transporter Default CLNROL-function setting EnableChecking the CLNROL- function Setting the CLNROL- function Disable Changing the RtyCnt value RtyCnt value in the CLNROL-functionOperation Example Tip Cleaning of the Roller Execution timing of the cleaningTools and Parts Setting Maintenance mode Setting Cleaning mode Cleaning the RollerShows the upper Roller after cleaning Tip 12 shows the upper Roller after cleaning Operation Cleaning of the fixed slots Cleaning of the Main UnitCleaning of the exterior Cleaning of the interiorCleaning of the magazine Cleaning of the cartridgeMovement and Shipping of the Autoloader Troubleshooting Phenomenon Recovery Procedure Power SupplyPhenomenon Recovery Procedure Cartridge Operation ConnectionsPhenomenon Recovery Procedure Autoloader Performance CleaningOthers Recovery Procedure P move system initialization Exceeding the recommended operation When Requesting Maintenance Other Matters to CheckAppendix a Specifications Autoloader Main UnitUniversal cleaning cartridge TD P/N LTO2 Data Cartridge TD P/N LTO1 Data Cartridge TD P/NAppendix B Optional Items and Supplies Optional ItemsSupplies Appendix C Error Code CMer Error CodeErr ×××× Messages Messages Related to the Drive InterfacePanel Operation and Other Messages Message DescriptionTandberg LTO2 Autoloader Installation and User’s Manual Tandberg Data ASA Kjelsasveien 161 N-411 Oslo Norway