Tandberg Data Tandberg LTO2 manual Do not cover the air inlet, Do not lift the device alone

Page 7

Cautions for installing, transporting, storing, and connecting

CAUTION

Do not lift the device alone.

This device weights 18 kg. Lifting it alone may injure your back. Be sure to transport or move the device with two persons.

Do not install in location other than the one specified.

Do not install this device in the location listed below or other than the location specified in this manual as a fire may occur.

Dusty place

Humid place such as near a hot water supply Install where exposed to direct sunlight

Unstable place

Do not cover the air inlet

Do not cover the fan on the back panel and air inlet on the front panel of the device as internal temperatures will rise, resulting in a fire or an electric shock as well as operation error.

Do not connect/disconnect the interface cable with the plug still inserted in the outlet.

Remove the power cable from the outlet before connecting/disconnecting the interface cable. Touching cables or connectors while the power cable is connected may lead to an electric shock or a fire due to a short-circuit, even if the power is OFF.

Do not use an interface cable other than the one specified.

Use an interface cable specified by TD and connect it after checking the device or connector. Using an interface cable other than the one specified or connecting the cable to the wrong connection point may lead to a fire due to a short-circuit.

Follow the instructions described below for handling and connecting the interface cable.

Do not step on the cable

Do not place items on the cable

Do not use the device with the cable connected loosely Do not use a damaged cable

Do not use a damaged cable connector Be sure to lock the fastening screws

- v -

Image 7
Contents Tandberg LTO2 Autoloader Trademarks FCC Class B NoticeDescription example in this manual Safety DescriptionsMandatory action Prohibited actionGeneral Cautions Safety CautionsDo not apply starburst wiring Do not lift the device alone Do not cover the air inletDo not disassemble, repair or modify by yourself Vii Figure Ⅰ Warning Label ① Revision History Contents Chapter Troubleshooting Chapter Daily MaintenanceChapter Cartridges Introduction Organization of this manual Symbols used in this manual Symbols used in this manualTip Overview of the Tandberg LTO2 Autoloader Tandberg LTO2 AutoloaderFront Panel of the Tandberg LTO2 Autoloader Names and Functions of the Parts・ Enter key Rear Panel of the Tandberg LTO2 Autoloader Liquid Crystal Display LCD Liquid Crystal DisplayCartridges Handling PrecautionsTransfer or Disposal of the Device Main UnitContents of the Carton Preparation Before Use SetupTransporter Locking Screw Instruction TAG Storing the Transporter Locking Screw for later use Scsi Cable ConnectionsAC Power Cable Connection AC Power Cable ConnectionAttaching and removing a Filter Element Attaching and removing the Filter ElementScsi ID Setting Switching on the Power Switch and the Power-On SequenceStart and Shutdown of the System Removal of the Magazine OperationLoading the Magazine Loading the MagazineLoading to Magazine Loading the CartridgeLoading to the Fixed Slots For using the Tandberg LTO2 Autoloader w/BCRs optionalOperation Examples For using the Tandberg LTO2 Autoloader w/BCR Removal from and Insertion to the Magazine Removal and Insertion of the CartridgesDisplay Eject Slot? Removal from and Insertion to the Fixed SlotsSlot Logical Numbers Organization of the Front Panel SwitchesFunctions of the Switches Operation of the Panel KeysPanel Operation Procedure Display Frm Slt 1? Menu Tree 1 Main Menu Menu CommandsRetry Mode Checking the Scsi ID Setting the Scsi IDOperation Example Changing the Scsi IDTip Display Drv. ID 0? Using the Emergency Release Key Using the Emergency Release KeyCartridges CartridgesData Cartridge Cleaning CartridgeSetting the Write-protect Switch Write-Protect SwitchBar Code Label Using Bar Code Labels PrecautionsGeneral Precautions Usage PrecautionsStandards for Prohibition of Use Service LifeStorage of Data Cartridges Cleaning Daily MaintenanceCleaning of the Drive Head Manually Cleaning of the Drive Head Default CLNROL-function setting Enable Cleaning the Roller inside of the transporterChecking the CLNROL- function Setting the CLNROL- function Disable RtyCnt value in the CLNROL-function Changing the RtyCnt valueOperation Example Tip Execution timing of the cleaning Cleaning of the RollerTools and Parts Setting Maintenance mode Cleaning the Roller Setting Cleaning modeShows the upper Roller after cleaning Tip 12 shows the upper Roller after cleaning Operation Cleaning of the interior Cleaning of the Main UnitCleaning of the exterior Cleaning of the fixed slotsCleaning of the cartridge Cleaning of the magazineMovement and Shipping of the Autoloader Phenomenon Recovery Procedure Power Supply TroubleshootingConnections Phenomenon Recovery Procedure Cartridge OperationCleaning Phenomenon Recovery Procedure Autoloader PerformanceOthers Recovery Procedure P move system initialization Exceeding the recommended operation Other Matters to Check When Requesting MaintenanceAutoloader Main Unit Appendix a SpecificationsLTO2 Data Cartridge TD P/N LTO1 Data Cartridge TD P/N Universal cleaning cartridge TD P/NOptional Items Appendix B Optional Items and SuppliesSupplies CMer Error Code Appendix C Error CodeErr ×××× Messages Related to the Drive Interface MessagesMessage Description Panel Operation and Other MessagesTandberg Data ASA Kjelsasveien 161 N-411 Oslo Norway Tandberg LTO2 Autoloader Installation and User’s Manual