Error code |
| Cause |
| Recovery Procedure | ||
|
|
|
|
|
| |
CMer****E0 | The | Autoloader | detected | internal | ・Replace the Autoloader (not including the Drive | |
hardware error. |
|
| Sled Assembly). | |||
|
|
| ||||
|
|
|
|
|
| |
CMer****E1~ | The Autoloader detected an error during | ・Remove the cartridge from the transporter. | ||||
・Switch off the power of the Autoloader and then | ||||||
CMer****E3 | the P move system initialization. | |||||
switch the power back on. | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
| The Autoloader detected an error during | ・Check whether there is any foreign matter in the | ||||
CMer****E4~ | transporter. | |||||
CMer****E6 | the P move system initialization. | ・Switch off the power of the Autoloader and then | ||||
|
|
|
|
| switch the power back on. | |
|
|
| ||||
CMer****E7~ | An error that occurred during the | ・Switch off the power of the Autoloader and then | ||||
CMer****E8 | operation of the bar code reader. | switch the power back on. | ||||
|
|
|
|
|
| |
CMer****ED~ |
|
|
|
|
| |
CMer****EF |
|
|
|
| ・Execute cleaning of the Roller.See”Section 5.1.2” | |
CMer****F0~ | The Autoloader detected an error during | |||||
・ If the phenomenon has a relapse,contact your | ||||||
CMer****F9 | error restoration. |
|
| |||
|
| nearest Customer Support Center. | ||||
CMer****FA~ |
|
|
|
| ||
|
|
|
|
| ||
CMer****FE |
|
|
|
|
| |
|
|
| ||||
D.err 0101 | The Autoloader detected timeout error |
| ||||
on the communication with the drive. |
| |||||
|
| |||||
D.err 0110 | The Autoloader detected parity error on |
| ||||
the communication with the drive. |
| |||||
|
| |||||
D.err 0111 | The Autoloader detected framing error |
| ||||
on the communication with the drive. |
| |||||
|
| |||||
D.err 0112 | The Autoloader detected overrun error |
| ||||
on the communication with the drive. |
| |||||
|
| |||||
D.err 0140 | The Autoloader detected a error on the |
| ||||
Load/Unload command. |
|
| ||||
|
|
| ||||
D.err 0170 | The Autoloader detected a error on the |
| ||||
communication with the drive. |
|
| ||||
|
|
| ||||
| The Autoloader detected a error on the | ・Switch off the power of the Autoloader and then | ||||
D.err 0180 | communication with the drive.(NAK | switch the power back on. | ||||
| retry over) |
|
| ・ If the phenomenon has a relapse,contact your | ||
| The Autoloader detected a error on the | |||||
| nearest Customer Support Center. | |||||
D.err 0181 | communication with the drive.(SNAK | |||||
| ||||||
| retry over) |
|
|
| ||
D.err 0102~ | The | Autoloader | detected | cartridge |
| |
D.err 010F |
| |||||
position or timeout error before issuinig |
| |||||
D.err 0113~ |
| |||||
Load/Unload/Unthread command. |
| |||||
D.err 013F |
| |||||
|
|
|
|
| ||
|
|
| ||||
D.err 0190 | The Autoloader detected timeout error |
| ||||
before issuing Unload command. |
| |||||
|
| |||||
D.err 0191 | The Autoloader detected timeout error |
| ||||
before finishing Unload command. |
| |||||
|
| |||||
D.err 0192 | The Autoloader detected state error on |
| ||||
the communication with the drive . |
| |||||
|
|
- 58 -