Operation 2 Press the "ENTER" key.

Display: STATUS

Operation 3 Press the "arrow" key and select the LOAD command. Display: LOAD

Operation 4 Press the "ENTER" key and define the command. Display: Load Drv?

Operation 5 Press the "arrow" key and select "Load Slt?" .

Display: Load Slt?

Operation 6 Press the "ENTER" key and execute the command.

Display: Complete (when the command ends normally.)

Err. xxxxxx (when an error occurs. xxxxxx is the error code.)

Tip

Loading by command is valid only when slots 8 to 10 among the fixed slots are all vacant slots.

When loading by command is executed, all cartridges housed in slots 5 to 7 within the magazine are moved to fixed slots.

Important

For using the Tandberg LTO2 Autoloader w/BCR

In using the LTO2 Autoloader w/BCR, slot 10 must be a free slot used to swap a cartridge during the inventory scan process. When you load the 2 cartridges to the fixed slots, i.e. slot 8 and slot 9, you can insert the cartridges into slot 5 and slot 6 only. If a cartridge is in slot 7, loading command is failed and error message of "S10 forBCR" is displayed on the LCD.Then, you remove the cartridge fro slot7 manually, and retry the loading command.

- 18 -

Image 34
Contents Tandberg LTO2 Autoloader FCC Class B Notice TrademarksSafety Descriptions Description example in this manualProhibited action Mandatory actionSafety Cautions General CautionsDo not apply starburst wiring Do not cover the air inlet Do not lift the device aloneDo not disassemble, repair or modify by yourself Vii Figure Ⅰ Warning Label ① Revision History Contents Chapter Troubleshooting Chapter Daily MaintenanceChapter Cartridges Introduction Organization of this manual Symbols used in this manual Symbols used in this manualTip Tandberg LTO2 Autoloader Overview of the Tandberg LTO2 AutoloaderNames and Functions of the Parts Front Panel of the Tandberg LTO2 Autoloader・ Enter key Rear Panel of the Tandberg LTO2 Autoloader Liquid Crystal Display Liquid Crystal Display LCDMain Unit Handling PrecautionsTransfer or Disposal of the Device CartridgesContents of the Carton Preparation Before Use SetupTransporter Locking Screw Instruction TAG Scsi Cable Connections Storing the Transporter Locking Screw for later useAC Power Cable Connection AC Power Cable ConnectionAttaching and removing the Filter Element Attaching and removing a Filter ElementSwitching on the Power Switch and the Power-On Sequence Scsi ID SettingStart and Shutdown of the System Operation Removal of the MagazineLoading the Magazine Loading the MagazineLoading the Cartridge Loading to MagazineLoading to the Fixed Slots For using the Tandberg LTO2 Autoloader w/BCRs optionalOperation Examples For using the Tandberg LTO2 Autoloader w/BCR Removal and Insertion of the Cartridges Removal from and Insertion to the MagazineRemoval from and Insertion to the Fixed Slots Display Eject Slot?Operation of the Panel Keys Organization of the Front Panel SwitchesFunctions of the Switches Slot Logical NumbersPanel Operation Procedure Display Frm Slt 1? Menu Commands Menu Tree 1 Main MenuRetry Mode Setting the Scsi ID Checking the Scsi IDChanging the Scsi ID Operation ExampleTip Display Drv. ID 0? Using the Emergency Release Key Using the Emergency Release KeyCartridges CartridgesCleaning Cartridge Data CartridgeWrite-Protect Switch Setting the Write-protect SwitchUsing Bar Code Labels Precautions Bar Code LabelUsage Precautions General PrecautionsStandards for Prohibition of Use Service LifeStorage of Data Cartridges Cleaning Daily MaintenanceCleaning of the Drive Head Manually Cleaning of the Drive Head Default CLNROL-function setting Enable Cleaning the Roller inside of the transporterChecking the CLNROL- function Setting the CLNROL- function Disable RtyCnt value in the CLNROL-function Changing the RtyCnt valueOperation Example Tip Cleaning of the Roller Execution timing of the cleaningTools and Parts Setting Maintenance mode Setting Cleaning mode Cleaning the RollerShows the upper Roller after cleaning Tip 12 shows the upper Roller after cleaning Operation Cleaning of the fixed slots Cleaning of the Main UnitCleaning of the exterior Cleaning of the interiorCleaning of the magazine Cleaning of the cartridgeMovement and Shipping of the Autoloader Troubleshooting Phenomenon Recovery Procedure Power SupplyPhenomenon Recovery Procedure Cartridge Operation ConnectionsCleaning Phenomenon Recovery Procedure Autoloader PerformanceOthers Recovery Procedure P move system initialization Exceeding the recommended operation When Requesting Maintenance Other Matters to CheckAppendix a Specifications Autoloader Main UnitUniversal cleaning cartridge TD P/N LTO2 Data Cartridge TD P/N LTO1 Data Cartridge TD P/NOptional Items Appendix B Optional Items and SuppliesSupplies Appendix C Error Code CMer Error CodeErr ×××× Messages Messages Related to the Drive InterfacePanel Operation and Other Messages Message DescriptionTandberg LTO2 Autoloader Installation and User’s Manual Tandberg Data ASA Kjelsasveien 161 N-411 Oslo Norway