Configure the settings relating to the host authentication [Host]

Click the [Host] tab on the "Authentication setup" page. (page 46)

The settings to restrict PCs (IP address) to access the unit can be configured on this page.

[Host authentication]

Select "ON" or "OFF" to determine whether or not to authenticate the host.

Default setting: OFF

[Access level]

Select the access level of the host from the following.

1.Administrator/2. Camera control/3. Live only Refer to page 46 for further information about the access level.

Default setting: 3. Live only

Note:

By clicking [i] of "Host check", the registered host can be selected and the selected host’s IP address can be checked.

The registered IP address will be displayed with the access level. (Example: 192.168.0.21 [1])

To delete the registered host, click the [DEL] button after selecting the IP address to be deleted.

Important:

Before selecting "ON" for "Host authentication", it is necessary to register IP addresses of the PCs to be allowed to access the unit and determine their access levels.

[IP address]

Enter the IP address of the PC to be allowed to access the unit.

Host name is unavailable for the IP address. Default setting: (blank)

Notes:

When "IP address/subnet mask" is entered, it is pos- sible to restrict PCs in each subnet.

For example, when "192.168.0.1/1/24" is entered and "2. Camera control" is selected for the access level, the PCs whose IP address is between "192.168.0.0" - "192.168.0.255" can access the camera with the access level "2. Camera control".

When the IP address already in use is entered and the [SET] button is clicked, the respective host infor- mation will be overwritten.

47

Image 47
Contents Network Operating Instructions Contents Viewer Software PrefaceAbout these operating instructions Trademarks and registered trademarksRefresh interval Jpeg Monitor Images on a PCMonitor images from a single camera StepAbout the Live Zoom buttons *2 0AUTO Mode *23Preset *2 W button *26Unit title Alarm occurrence indication button *24Frame 5TrackMonitor images from multiple cameras Action at an Alarm Occurrence Action at an Alarm OccurrenceAlarm type About Avmd Advanced Video Motion Detection About the image recognition functionIntruder detection Detection of abandoned or removed objectsTrack About Live page when Avmd is activatedTransmit Images onto an FTP Server Obtain images on the SD memory card Save images on the SD memory cardDirectory structure of sddata Equipped security functions Access restrictions by changing the Http portAbout the Network Security of This Unit How to display the setup menu How to operate the setup menu About the operation window 3Setup Server setup buttonNetwork setup button Maintenance buttonConfigure the basic settings Basic Configure the basic settings of the unit Basic setupAvailable value 1 Default setting Alarm status update modeDefault setting Real time Alarm status portConfigure the settings relating to the NTP server NTP Information about SD memory card SD memory card setupSize of SD Image quality Memory card Super fine Fine Image capture size VGAImage capture size Qvga Default setting None Stop bitDefault setting 1 bit Communication speed Default setting 8 bitCH selection Total bit rateJpeg setup Calculation of refresh interval Jpeg Return About the individual setup menuRefresh interval of Jpeg monitoring clients Refresh interval of Jpeg receiving devicesZoom buttons, Focus buttons, Control pad/buttons Configure the settings relating to camera CameraAbout the operation panel Configure the settings relating to audio Audio Cable compensation AuthenticationAudio output port PC to Unit Default setting blank IP address Configures the multi-screen settings Multi-screen setupAvailable value -, 1 Default setting Camera title Available value blank, 1 Step Configure the Avmd settings Video analytics setupSet the detection program Avmd Number of characters that can be entered 1 20 charactersStep Set the depth automatically Set the detection depthSet the depth manually Available value 0000 Step How to configure the schedule settingsSet the Avmd schedule Schedule How to delete the set schedule Alarm setup Configure the alarm settings Alarm setupConfigure the settings relating to the alarm action Alarm Command alarm Auto modeOFF Default setting Terminal alarm 1 to Default setting OFF Video loss CH1 toAlarm image setup AUX name Alarm output terminal setupMail notification setup Panasonic alarm protocol Panasonic alarm protocol setupAccess level User authenticationDefault setting OFF User name Default setting blank Password Retype passwordDefault setting OFF Access level Host authenticationConfigure the settings relating to the mail server Mail Configure the settings of the servers Server setupDefault setting blank Control port Configure the settings relating to the FTP server FTPFTP mode Default setting Passive FTP server addressDefault setting OFF IP address Configuring the network settings Network setupConfigure the network settings Network Network setupDefault setting Auto FTP access Default gatewayDefault setting Manual Primary DNS, Secondary DNS Default setting blank Line speedWAN Default setting blank User name Configure the settings relating to Ddns DdnsAccess interval Default setting OFF Host nameCommunity name Configure the settings relating to Snmp SnmpDefault setting blank Unit location FTP periodic transmission Default setting OFF DirectoryDefault setting blank Interval FTP periodic transmissionUncheck the check box of the desired day of the week Time & date Maintenance of the unit MaintenanceError message Check the system log System logHow to upgrade the firmware Upgrade the firmware UpgradeInitialize/restart the unit Initialization About the Displayed System Log Error indications relating to SmtpError indications relating to FTP Category Content DescriptionError indications relating to NTP Error indications relating to DdnsCause/solution TroubleshootingSymptom Symptom Symptom Symptom Operating Instructions Cause/solution Reference Pages Solutions Images are not displayed or refreshed smoothly Panasonic Canada Inc