[Audio output port (PC to Unit )]
Enter the transmission port number (the port number on the unit used to receive audio data transmitted from the PC).
Available value: 1024 - 50000 (Only even numbers are available.)
Default setting: 34004
Note:
The transmission port number entered for "Audio output port (PC to Unit)" will be used only when transmitting
[Authentication]
Select an access level for audio transmission/reception from the following. Refer to page 46 for further informa- tion about the access level.
Level 1 only/Level 2 or higher/All users Default setting: All users
Notes:
•Images and audio will not be synchronized. Therefore, images and audio may not always match.
•Audio may be interrupted depending on the network environment.
Configure the settings relating to coaxial communication [Coaxial setup]
Click the [Coaxial setup] tab on the "Camera setup" page. (☞ page 26)
The settings relating to camera control and cable compensation with coaxial communication can be configured on this page.
[CH No.]
Select a channel to configure the setting, and configure the following items.
[DATA]
Select "ON" or "OFF" to determine whether or not to control cameras with the coaxial communication. ON: Controls cameras with coaxial communication. OFF: Not controls cameras with coaxial communication. Default setting: ON
[Cable compensation]
Select the desired settings for cable compensation (the function to compensate the attenuation of video input signals) according to the cable length.
Perform the settings for the cable compensation proper- ly according to the cable length.
Otherwise camera pictures may not be displayed/ recorded correctly.
*The following cable length settings are references when using
S:Less than 400 m {1 300 ft.}
M:400 m {1 300 ft.} to 700 m {2 300 ft.}
L:700 m {2 300 ft.} to 1 200 m {4 000 ft.} Default setting: S
32