52Installing the Secure Router 4134 chassis and hardware components
Powering up the router
Use the procedure in this section to power up your Secure Router 4134.
Prerequisites
•Ensure all installation procedures are complete.
•Ensure an operator console is connected to the Secure Router 4134.
•Ensure the Secure Router 4134 is connected to a power source.
Procedure steps
Step Action
1For an AC power supply, press the rocker switch located on the power supply to the on position ( ).
2On a DC power supply, ensure the DC power source is on.
3Verify that the power supply status LED for each power supply is green.
4Verify that the fan status LED is green.
5Verify that the air flows from the cooling fans through the vents of the chassis.
The fan tray red (fail) LED can illuminate briefly while the fans power to operational speed.
--End--
If status LEDs do not illuminate green, see Nortel Secure Router 4134 — Troubleshooting
Verifying a successful installation
Use the information in this section to verify that you have successfully installed the Secure Router 4134 and its components.
If any LED behavior indicates failure or is suspect, see Nortel Secure
Router 4134 — Troubleshooting (NN47263-700).