2.13 Connection of the "LED" remote indications unit

This unit is connected to connectors XR1 and XR2 of the remote relay boards of the rectifier-inverter and Static Switch Cubicles (see the location of these boards in the figures of the "connection of power circuits" section).

For the installation of the unit and details of connections at the unit end, see the instructions delivered with the unit nr 5102990400.

recommended cable cross-section: 1 mm2.

2.14Connection of "Tele Monitor" remote control and indication unit (option)

This unit is connected by means of a signal loop connecting the XR10 connectors of the RAUZ 1 boards of the rectifier-inverter and Static Switch Cubicles to the unit connectors. These RAUZ 1 boards are located near the remote relay boards.

recommended cable cross-section: shielded 0.4 mm2 cables;

consult manual 6739388XU for further information.

Connection of "Tele Monitor" remote control and indication unit

RAUZ 1 board

1

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XM098

XM097

XR11

 

 

 

 

 

XM096

 

XR10

connector XR10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reception

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reception +

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

to connector XR081

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

transmission

 

 

 

 

 

 

 

 

 

 

 

2

on the COMZ board

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in the "Tele Monitor" unit

transmission +

 

 

 

 

 

8

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 7

to connector XR10

of another rectifier-inverter or static switch cubicle

Fig. 26

2.15 Final installation steps

After making the connections:

install the front and rear base plates of the cubicles, clipping them to the feet of the cubicles (unless the connecting cables are fed through these openings);

refit the terminal shields of the terminal blocks, switches and circuit breakers.

34006451EN/AC - Page 30

Image 30
Contents Installation manual Mgetm GalaxyTM34006451EN/AC Contents Characteristics Characteristics common to all cubiclesCharacteristics of Static Switch Cubicles Static Switch CubicleCharacteristics of rectifier-inverter cubicles Rectifier-inverter cubicleElectrical parameters for Mains 2 415 Electrical parameters for selecting protective devicesElectrical parameters for Mains Rated Mains 1 current InverterElectrical parameters for determining cable cross-sections Parameters for single-unit UPS cablesInstallation with parallel frequency converters Installation with parallel UPSs with a centralised SSCNF C 15-100 authorizes a maximum of 4 cables per phase Maintenance Bypass cubicle Mains Inverter Mains 1 mains Load Side clearances provided by the spacing uprights Rear HandingPositioning the cubicles FrontCubicle footpads Rear Floor loads figureCubicle layout on false floor or normal floor figures 6, 7 Connection via the bottomLayout for a single-unit UPS with one battery cubicle Rear Power circuit wiring diagrams Diagram for a frequency converter with batteriesSpecial case Diagram for a frequency converter without batteries Example of a 2 parallel UPS rectifier-inverters with SSCModular UPS cubicle External maintenance bypass cubicle Cubicle mounting and connection Mounting of the left and right cubiclesInternal connections between cubicles XMGD05XFGD06 Left cubicle of single-unit or parallel UPS with SSC Connection of power circuitsGeneral Cross-section AAXR9 Right cubicle of single-unit UPSXR1 XR8 XR2 XR5 XR3 XR6 XR4 XR7XR2 XR5 Right cubicle of a parallel UPS with SSCFront Rear XR3 XR6 XR4 XR7Connection of auxiliary circuits on the remote relay board XR1 XR2 XR3 XR4Connections between Apoz boards Connection to battery circuit breaker QF1Emergency shutdown Connections between rectifier-inverter cubiclesXM XM XM XM Connections between Misi boards modular UPSs MisiUPS Misi Acpz board of the Static Switch Cubicle XR8 XR9 XR5 XR6 XR7Connection of the battery Temperature Monitor optional ConnectionsXR2 XR1 Temperature Monitor installation in a battery room Temperature Monitor baseDimensions of the Temperature Monitor 75 x 75 x 21 mm Final installation steps Connection of the LED remote indications unitMains 2 line protection Rated inverter output kVA Maximum permissible currentQ4S Cubicle mountingLeft cubicle XF1-XF2 XM1-XM2Right cubicle of a 2000 kVA Static Switch Front viewLeft cubicle of a 2000 kVA Static Switch FrontRear Front view Rectifier-inverter cubicle 120 to 1200 kVA Static Switch CubiclesDetails of earthing connections in the various cubicles Inverter InputKVA Static Switch Cubicles Tele-Monitor unitComz 34006451EN/AC 34006451EN/AC 34006451EN/AC 34006451EN/AC