Siemens DataNET Hub (DNH) Troubleshooting, Configuration Conflicts, Cabling errors Example

Page 73

Troubleshooting

Description

This chapter is intended for maintenance personnel.

 

Failure of the DNH to establish a link is the principle cause of most hub

 

failures. Typical problems are:

 

Configuration Conflict

 

Link Signal Quality

Configuration Conflicts

Cabling errors:

Example

NOTE

The DNH port green LED is off, or intermittently flashes between green and red. This can indicate a configuration conflict caused by a faulty ca- ble or a wrong connection or improper configuration parameters.

1.Inspect all cable and connectors for damage.

2.Verify that the cable is connected to the correct Hub half and correct Port.

3.Verify that the Channel ‘A’ link is connected to the ‘A’ Hub half and that the Channel ‘B’ link is connected to the ‘B’ Hub half.

4.Verify that both Channels A & B use the same port number on their respective Hub half.

5.Display the Port Status screen by connecting a PC to the Configura- tion Port, logging in, and then typing display links. Verify that all Ports are connected as expected; see example below.

The following example shows that Port 1 on the B Hub is incorrectly con- nected to Port 1 Channel A, on device 172.16.99.7.

local> display links

 

 

Port status for 172.16.99.3, B

 

 

Port:

Medium: Status:

"A" connected to:

"B" connected to:

1

Copper Validation

 

172.016.099.007, 1A

2Copper Unconnected

3Copper Unconnected

4Copper Unconnected

5Copper Unconnected

6Copper Unconnected

7Copper Unconnected

8Copper Unconnected

9Copper Unconnected

Ethernet Offline

The Ethernet port is always shown as Offline on the ‘B’ Hub half because the Ethernet port is always disabled on the ‘B’ Hub.

2000585-001

Data Communications Setup 65

Image 73
Contents December User’s Manual 2000585-001 Advance DataNET Hub DNHCopyright Notice Table of Contents Table of Contents Preface Audience & Purpose Chapter ContentsGetting Help Before You Call Technical SupportSafety Practices and Precautions Safety Practices and Precautions Description OverviewDual Hub Modules PortsAdvance Communi- cations System Package ConfigurationsEthernet Bridging DataNET Hub HierarchyDNH Links DataNET Hub OperationDNH and Maxum Com Boards Transparency DataNET SwitchingDefinitions DataNET Hub Specifications DataNET Hub Specifications DataNET Hub Specifications Communication Cable Type Vendors & P/N Installation NotesComparisons DataNET CableDataNET Hub Specifications DataNET Hub Specifications Zone 1 Wall Mount Dimension Table Description Metric InchesZone 1 Wall Mount Dimension Table Page Introduction Installation OverviewDescription Receipt of DNH Unpacking Reporting Damage Unpacking and InspectionInstructions Package Configurations Wall Mounting Wall or Rack Mounting InstallationRack Mounting CE Installations Wiring Requirements Description Wiring of Power to DataNET HUB Site Wiring RequirementsDataNET Channels Cable Cable Type Vendors & P/N Installation NotesRecommended DataNET CE Installations NEC Div 2 or Non Hazardous Areas Copper Wire Site RequirementsDataNET Fiber Optic Cable Connections Ethernet Communica- tion Links CE Installation Kit Instructions CE InstallationsCE Installations Before You Begin Wiring ConnectionsTypes of Connections DNH Power Supply AC Power Mains ConnectionsInstallation Note Before You Begin Step ActionInstall 15-Ampere circuit breakers, disconnect switches or AC Power Mains Connections Description Hubs DataNET Copper ConnectionsPort Connections DataNET Ports+ Important Cable Impedance SettingsMaster Port Connectors TB15 TB18 Signal Equalizer Board Downlink Wiring withoutDescription Instructions DataNET Hub Signal Equalizer BoardRepeat the procedure for each connected port on the Hub Sample Calculations Equalizer Board SettingsRecommended Calculation OneExample Comparing SignalsOption 1. Connection Point Option 2. Connection Point View MeasurementsInstructions & Examples Step Action + 2.1 dB DataNET Fiber Optic Coupler DataNET Fiber Optic ConnectionsRX & TX Connections Fiber Optic Cable Type Port Connections Page Active Ethernet Port Ethernet ConnectionsPin No MDI Function 10BASE-T Cable RequirementsIntroduction Overview Command Line Definitions Important ChecklistTasks Check Chapter Preview Configuring Your PC Learning Hint Setting Network AddressConfiguring Your PC Click Terminal Settings button Configuring Your PC Establishing a Connection Before You Begin Password ProtectionGetting Started How to Log Out Password FormatHow to Log On How to ChangeRemote Connection Log On At the prompt type login password IP AddressSetting Network Address Config address ip Assigning an IP Address IP Address How to Assign an IP AddressOverview Available IP AddressesFirmware Updates MAC Address Con- figuration At the Local prompt type config address etherenetClick on Send Text File Board Status LEDs Startup LED Status System Status LEDsAdvance DataNET Hub Communication boards have status LEDs For monitoring the DNH operationYellow Warn LED Blink Codes Red Fault LEDHub Port LEDs Green Normal LEDLED Ethernet Port LEDs Cross Link StatusConfiguration Conflicts TroubleshootingCabling errors Example Errors Configuration ParameterInstructions Signal Quality ProblemsTroubleshooting Description Unique Commands Command DescriptionsReset Password passwordTimeout on Timeout offConfig display Command Config netmask Command Config address ip command Config device id CommandConfig iproute Del Command Display Command Download Command Display links CommandExample local display links Dn setuptime Events Command Dn CommandCommand Descriptions Dn module on dn module off Help Command List Command Command DescriptionLogin Command Port Command Logout Command Netstat CommandExamplelocal netstat dn clear Test Command Timeout Command Trace Command Validation timeout Command Captured frames Verbose CommandParts Catalog Overview How to Place an OrderPart Description Ordering Number Available PartsAvailable Parts