Troubleshooting, Continued
Signal Quality Problems
Instructions
If a DNH port green LED is off, or intermittently flashes between green and red the signal levels for that port are either too high or low relative to the other Hub ports.
If a port link fails to connect at all, the port can be set to a test mode The test mode will cause port activity to occur approximately every 50 milli- seconds instead of approximately every 7 seconds as it would for an un- connected link. While in the test mode the signal for that port can be measured.
1.Connect a standard
2.Open HyperTerminal program on your PC; reference Configuring Your PC, page 49.
3.Connect and Log on to the DNH.
4.At the > prompt type: port stop num Where num is a port number 1 through 9
5.Press ↵ Enter.
6.At the > prompt type: test num
This places the selected port into a hardware diagnostic mode.
7.Using Option 1 or 2, (as outlined in ‘Hub Signal Equalizer Board with Generic Cable’ section page 37) connect an oscilloscope to the port under test.
8.The signal received at the slave should be between ~0.75 v
9.If the signal is smaller than ~0.75 v
10.At the > prompt type: port start num Where num is a port number 1 through 9.
11.Press ↵ Enter.
Data Communications Setup • 67 |