Siemens DataNET Hub (DNH) user manual Del Command Display Command

Page 81

Command Descriptions, Continued

“del” Command

“display” Command

This command deletes selected items from the hub’s Source Address Table (SAT). The command offers options to delete all entries or se- lected entries by IP address or by MAC address. The command syntax is as follows:

del xx:xx:xx:xx:xx:xx or del xxx.xxx.xxx.xxx

where xx:xx:xx:xx:xx:xx is a MAC address in colon-separated hexadeci- mal format, and xxx.xxx.xxx.xxx is a dotted-decimal IP address. Note that in both cases, leading zeros must be included in the addresses. That is, if the IP address of an entry is “192.1.2.3,” the address must be en- tered as “192.001.002.003.” If the designated address is not found in the SAT, the hub-half displays an error message:

Address xx:xx:xx:xx:xx:xx not found or Address xxx.xxx.xxx.xxx not found

If the deletion is successful, the hub-half confirms it with a message:

Address xx:xx:xx:xx:xx:xx deleted or Address xxx.xxx.xxx.xxx deleted

The entire SAT may be cleared with the command:

del all

Note that the SAT always contains one entry that may not be deleted, for the hub-half itself.

Display the Source Address Table (SAT). This displays the MAC ad- dresses of all stations known to the hub-half. IP addresses are also shown for all stations whose IP addresses the hub-half has learned. The list is sorted by IP address; entries that do not include an IP address are listed following those that do. The port through which the station is reached is displayed in the right-hand column. This generates a display similar to the following:

local> display

 

 

 

MAC Address:

IP Address:

Port:

 

00:10:5A:19:08:76

172.16.8.208

Port 9

0

00:A0:24:11:EC:7D

172.16.8.209

Port 9

1

00:80:44:11:22:32

172.16.9.205

Port 1

2

02.11.22.44.32.10

172.16.9.206

Ethernet

3

00:60:47:8D:F6:20

172.16.9 207

Local

4

00.80.44.44.33.22

 

Crosslink

5

00:A0:24:11:DD:70

 

Port 3

6

total entries

in SAT: 7

 

 

local>

 

 

 

2000585-001

Command Summary 73

Image 81
Contents December User’s Manual 2000585-001 Advance DataNET Hub DNHCopyright Notice Table of Contents Table of Contents Preface Audience & Purpose Chapter ContentsGetting Help Before You Call Technical SupportSafety Practices and Precautions Safety Practices and Precautions Description OverviewDual Hub Modules PortsAdvance Communi- cations System Package ConfigurationsEthernet Bridging DataNET Hub HierarchyDataNET Hub Operation DNH LinksDNH and Maxum Com Boards DataNET Switching TransparencyDefinitions DataNET Hub Specifications DataNET Hub Specifications DataNET Hub Specifications Communication Cable Type Vendors & P/N Installation NotesComparisons DataNET CableDataNET Hub Specifications DataNET Hub Specifications Zone 1 Wall Mount Dimension Table Description Metric InchesZone 1 Wall Mount Dimension Table Page Introduction Installation OverviewDescription Receipt of DNH Unpacking Reporting Damage Unpacking and InspectionInstructions Package Configurations Wall Mounting Wall or Rack Mounting InstallationRack Mounting CE Installations Wiring Requirements Description Wiring of Power to DataNET HUB Site Wiring RequirementsCable Cable Type Vendors & P/N Installation Notes DataNET ChannelsRecommended DataNET Copper Wire Site Requirements CE Installations NEC Div 2 or Non Hazardous AreasDataNET Fiber Optic Cable Connections Ethernet Communica- tion Links CE Installation Kit Instructions CE InstallationsCE Installations Wiring Connections Before You BeginTypes of Connections DNH Power Supply AC Power Mains ConnectionsInstallation Note Before You Begin Step ActionInstall 15-Ampere circuit breakers, disconnect switches or AC Power Mains Connections Description Hubs DataNET Copper ConnectionsPort Connections DataNET Ports+ Important Cable Impedance SettingsMaster Port Connectors TB15 TB18 Signal Equalizer Board Downlink Wiring withoutDescription Instructions DataNET Hub Signal Equalizer BoardRepeat the procedure for each connected port on the Hub Sample Calculations Equalizer Board SettingsRecommended Calculation OneExample Comparing SignalsOption 1. Connection Point Option 2. Connection Point View MeasurementsInstructions & Examples Step Action + 2.1 dB DataNET Fiber Optic Connections DataNET Fiber Optic CouplerRX & TX Connections Fiber Optic Cable Type Port Connections Page Active Ethernet Port Ethernet ConnectionsPin No MDI Function 10BASE-T Cable RequirementsOverview Command Line Definitions Important Checklist IntroductionTasks Check Chapter Preview Configuring Your PC Learning Hint Setting Network AddressConfiguring Your PC Click Terminal Settings button Configuring Your PC Before You Begin Password Protection Establishing a ConnectionGetting Started How to Log Out Password FormatHow to Log On How to ChangeRemote Connection Log On At the prompt type login password IP AddressSetting Network Address Config address ip Assigning an IP Address IP Address How to Assign an IP AddressOverview Available IP AddressesFirmware Updates At the Local prompt type config address etherenet MAC Address Con- figurationClick on Send Text File Board Status LEDs Startup LED Status System Status LEDsAdvance DataNET Hub Communication boards have status LEDs For monitoring the DNH operationYellow Warn LED Blink Codes Red Fault LEDHub Port LEDs Green Normal LEDLED Ethernet Port LEDs Cross Link StatusTroubleshooting Configuration ConflictsCabling errors Example Errors Configuration ParameterInstructions Signal Quality ProblemsTroubleshooting Description Unique Commands Command DescriptionsReset Password passwordTimeout on Timeout offConfig display Command Config netmask Command Config address ip command Config device id CommandConfig iproute Del Command Display Command Display links Command Download CommandExample local display links Dn setuptime Events Command Dn CommandCommand Descriptions Dn module on dn module off Help Command List Command Command DescriptionLogin Command Logout Command Netstat Command Port CommandExamplelocal netstat dn clear Test Command Timeout Command Trace Command Validation timeout Command Captured frames Verbose CommandParts Catalog Overview How to Place an OrderPart Description Ordering Number Available PartsAvailable Parts