JVC TDR6 installation and operation guide Ber, Message No services available

Page 33

Command

Description

Parameters / Response Values

 

 

 

Raw BER

Query-only; displays the raw bit error rate; this rate is the error

 

rate of the signal as it is received from the satellite, before error

 

 

correction is applied.

 

 

 

 

BER

Query-only; displays the bit error rate; this value represents the

 

number of errors detected in the signal after error correction is

 

 

applied. This rate should be a zero for correct performance.

 

 

 

 

Rx Level

Query-only; displays the power level of the input signal.

value in .dBm

 

 

 

Peak Jitter

Query-only; displays the difference, or jitter, between the STC

value in ns

 

and PCR clocks.

 

 

 

 

Details>Input>Status>ASI: allows you to query the presence of the ASI signal, as well as other transport stream parameters

Signal

Query-only; displays if the ASI signal is present or not

Present, Absent

 

Note: Signal is only available when

 

 

Details>Input>Config>Select>Input is set to ASI.

 

 

 

 

Transport

Query-only; displays the lock status of the transport stream

Locked, Unlocked

 

 

 

Rate

Query-only; displays the output rate for the QPSK demodulator

value in bps

 

 

 

Peak Jitter

Query-only; displays the difference, or jitter, between the STC

value in ns

 

and PCR clocks.

 

 

 

 

Details>Service: consists of two submenus, Number and Auto Select, which enable you to query and select the services available in the transport stream.

Once you have selected a service, the Video Decoder, Audio Decoder, and User Data menus display the PIDs available for the selected service.

Number

Selects a service from those available in the transport stream.

Displays a list of available services.

 

Once a service is selected, the TDR6 processes that service

Each available service in the transport stream

 

until:

consists of a program number, a service

 

Another service is selected

name, and a service provider.

 

or

If the transport stream does not contain

 

The selected service is no longer available in the transport

service names and providers, only the

 

stream

program numbers are displayed.

 

 

If the transport stream input is not connected,

 

 

or if it lacks PSI information, the LCD displays

 

 

the message: No services available.

 

 

 

Auto Select

Determines which service, including audio and data services,

On – when Auto Select is set to On, the TDR6

 

that the TDR6 will select when any of the following events occur:

automatically selects the first available service

 

The TDR6 power is turned off and then restored, or the unit is

in the transport stream.

 

reset

Note: If you change the Auto Select function to

 

The TDR6 loses and then re-establishes lock on the transport

On after you have selected a service, the

 

stream

TDR6 will continue to process the service you

 

Note: Since the typical SCPC transmission consists of a single

selected until one of the events occurs, then

 

the TDR6 selects the first available service in

 

service that includes of a single video/audio pair, the Auto Select

 

the transport stream.

 

feature was added to simplify the configuration process for

 

Off – when Auto Select function is set to Off,

 

typical SCPC users. When the Auto Select feature is enabled, or

 

set to On, the decoder automatically selects the service with the

the TDR6 searches the transport stream for

 

lowest service number first, then selects the video component

the last service you manually selected.

 

with the lowest PID, and finally selects the audio components

If the service is found in the transport stream,

 

with the lowest PIDS for audio A/B.

the TDR6 selects the service, and the LCD

 

With Auto Select set to Off, the decoder can be configured to

displays the program number, service name,

 

process a particular service, and within that service, to process

and service provider.

 

selected video and audio services.

If the service is not found in the transport

 

 

stream, the LCD displays Service Not

 

 

Available, the TDR6 does not select a service,

 

 

and no video, audio, or user data will be

 

 

output.

 

 

 

Front Panel

01-0870-401B 01/03

23

Image 33
Contents TDR6 Electric Shock Hazard Contents Chapter Troubleshooting Chapter Configuring the TDR6Appendix F Option Module Overview Appendix G Demodulator Application NotesPreface Using This GuideLocating Information Important InformationFront Panel Navigation Issuing CommandsDisplays RevisionErrors Cartons and Packing MaterialsLCD Display IMQ SAAOVE MitiUse Approved Attachments Only Viii 01-0870-401B 01/03 Overview Overview Overview 01-0870-401B 01/03 Installing the TDR6 AC Power CordsVentilation Power-up Sequence Connecting to a Power SourceBasic TDR6 SD Configuration with No Option Modules Installed TMAC-6125 Ports Connecting to a Remote UnitConnecting to a Network TDEC-6161 Ports Cabling the Analog Audio ConnectorsCabling the TDEM-6110 LNB Power01-0870-401B 01/03 TDR6 Front Panel Front PanelTDR6 DTV Receiver/Decoder Menu Structure LCD Text Formats LCD Display LCD SymbolsData a Menu Qpsk Key Character Displayed Correcting Mistakes Example Command Description Parameters / Response Values DVBQPSK, 8PSK, 16QAM DetailsInputConfigFilter allows you set the PCR filter BER Message No services availableNTSC, PAL, Auto PIDMPEG-2 Value, that does not begin with EID Important Considerations when entering Biss EkeyMAC ControlEIA-232 used to configure the remote portRestoring a User Configuration Restoring a Default ConfigurationSaving a User Configuration Locking the Front PanelSetting the Time Setting the DatePerforming a System Reset Unlocking the Front PanelUsing a Remote Unit Configuring Remote Software ParametersRemote Port Ethernet Port Command TypesBaud 01-0870-401B 01/03 TDR6 HD/SD Back Panel with Remote Designators Informational Remote Commands Response Error Messages Explanation Action RequiredAuto DelayChannelmode LangSource MPEG-2, Atsc MPEG2 Sample RateVOL BissBiss Status Biss ModeDC Autosel DC FilterDmlock DclockEbno LNBHdvd Delay FaultlogclearRolloff 35RCRO, 25RCRO TuneMC Access FP RO, RW MC Access CodeMC Access Unlock MC Config ListPgca Authorization MC Default RestorePgca Mode MC Ethernet IP AddressData Pgca TimeoutHandshake InterfaceVBI VD DelayVBI Control VBI FormatVD Setup VD Mode PAL, NTSC, AutoVD PID VD SubmodeConfiguring the TDR6 ConfigurationQuick Start Selecting a Service Setting Local Date and Time Detailed TDR6 ConfigurationTDR6 Detailed Configuration Procedure Demodulator ConfigurationConfiguring the L-Band Carrier Frequency Qpsk Parameter Front Panel Menu Remote Command01-0870-401B 01/03 Fault Reporting and Monitoring TroubleshootingCurrent Faults Fault HistoryCommand Mnemonics Abbreviation Option Module Fault Descriptors are defined in the following table Viewing the Fault History Log Viewing Current FaultsMinimum E b /N 0 dB Input Status LED Not IlluminatedPerformance Problems FACTORY-CONFIGURABLE Features Technical SpecificationsStandard Features Demodulator a D Default ConfigurationsStandard-Definition Video Decoder High-Definition Video DecoderRemote Control Audio Decoder a FUser Data a B Ethernet Front Panel Access01-0870-401B 01/03 Port Pinouts Fault Relay Port Pin SpecificationsEthernet Port Pin Assignments Signal Signal Definition User Data port Pin Specifications Standard RS232Number Synchronous Asynchronous TMAC-6125 Specifications Port SpecificationsTDEC-6100 Specifications TDEC-6161 SpecificationsTAUD-6100 Specifications LNB Port Specifications TDEM-6110 Specifications01-0870-401B 01/03 PAL Tiernan VBI Data TransmissionTiernan VBI Data Transmission Tiernan Proprietary Closed Captions Tiernan CC Tiernan CC Mode is for Ntsc Format OnlyDVB 422 Expanded Windows, 16-line and 32-line Lines Expanded Windows Field for an Encoded Picture Frame Tiernan Closed Captions Front Panel Commands Front Panel Commands for Encoder ConfigurationVE TCC Remote Commands for Encoder ConfigurationVE Vbipass 32LINES01-0870-401B 01/03 Typical Option Module Option Module OverviewOption Module Overview Demodulator Application Notes Industry Standard LNB FrequenciesDemodulator Tuner SAW Filter Spacing Information RateEb/N0 Definition Output Spectrum WidthMinimum and Maximum Information Rates TransponderDemodulator Low Eb/N0 Alarm Estimating Eb/N0 Using a Spectrum AnalyzerEb/N0 Estimation Algorithm Spectrum AnalyzerDiagnostic Commands Offset = Actual RF Programmed RF Table Top and Rack Mount Installation Instructions Rear Rack Mount Instructions Fuse Rear Rack Bracket Mounting Instructions01-0870-401B 01/03 Index Index