JVC TDR6 installation and operation guide DetailsInputConfigFilter allows you set the PCR filter

Page 32

Command

Description

Parameters / Response Values

 

 

 

LO Freq

Sets the frequency to match your LNB downconverter local

2000 to 15000MHz

 

oscillator frequency.

 

 

Note: The IF frequency is the absolute value of the difference

 

 

between the RF frequency and the LO frequency. The

 

 

demodulator has a valid IF frequency in the range of 2150 MHz

 

 

and 950 MHz. Entering values for RF or LO that equal an out of

 

 

range IF frequency value will result in an IF value that is either

 

 

the maximum or the minimum IF frequency.

 

 

 

 

Code Rate

Sets the Viterbi code rate

QPSK: 1/2, 2/3, 3/4, 5/6, or 7/8

 

 

8PSK: 2/3, 5/6, 8/9

 

 

16QAM: 3/4, 7/8

 

 

 

Sym Rate

Sets the demodulator to the frequency of the incoming RF signal.

37500000 sps and 1000000 Sps

 

Note: If an out-of-range value is entered the TDR6 will not

To convert symbol rate to data rate, use the

 

accept the new value and will revert to the previous value

following equation:

 

entered.

Symbol rate x 2 x (188/204) x FEC code rate

 

Since the data rate is proportional to the symbol rate, entering a

 

 

data rate value might fail if the corresponding symbol rate is out

 

 

of range.

 

 

Converting a symbol rate to data rate and vice versa may be

 

 

subject to a small rounding error. The error is less than

 

 

0.00001%. It is advisable to use the symbol rate representation

 

 

when entering parameters if a conversion error cannot be

 

 

tolerated.

 

 

In cases where the demodulator is not locking on the carrier, it is

 

 

necessary to add an offset to the symbol rate. This compensates

 

 

for the symbol rate drift. The range of the offset is between

 

 

0.0002% and 0.0006%; in general a value of 0.0004% proves

 

 

successful to lock on the carrier in these cases.

 

 

 

 

Data Rate

Sets the data rate of the transport data stream

2 to 48Mbps

 

 

To convert data rate to symbol rate, use the

 

 

following equation:

 

 

Data rate x 1/2 x (204/188) x 1/FEC code rate

 

 

 

LNB Power

Sets the voltage of the LNB

Off, 13 V, 18 V

 

 

 

Acq Range

Defines the size of the frequency range over which the

0 to 7500000 Hz

 

demodulator will search for the carrier.

 

 

 

 

Details>Input>Config>Filter: allows you set the PCR filter

 

 

 

 

PCR Filter

Sets the PCR (program clock reference) filter for normal

Normal: set for normal operations

 

operations or operations over an ATM network.

ATM: set for operations over an ATM network

 

 

 

Details>Input>Status>RF: allows you to query the receive signal Eb/N0 level, the carrier offset, and the current lock status of the demodulator, decoder, and transport stream; this menu only applies to the currently active RF input.

Eb/N0

Query-only; displays the Eb/N0 of the RF receive signal

Displays the value in dB; value is ± 2 dB

 

Note: Eb/N0 is only available when

Eb/No values above 16 dB are not significant.

 

Details>Input>Config>Select>Input is set to RF.

 

 

 

 

Offset

Query-only; displays the RF offset.

Frequency in MHz

 

The Offset measures the difference, in MHz, between the actual

 

 

carrier frequency received by the TDR6 and the carrier

 

 

frequency the TDR6 calculates by subtracting the LO parameter

 

 

from the RF parameter. For optimum performance, the Offset

 

 

parameter should be as close to zero as possible.

 

 

For more information regarding the offset, refer to the chapters

 

 

on configuration and troubleshooting. Also refer to the appendix

 

 

on the QPSK demodulator.

 

 

Note: Offset is only available when

 

 

Details>Input>Config>Select>Input is set to RF.

 

 

 

 

Demod

Query-only; displays the lock status of the demodulator

Locked, Unlocked

 

Note: Demod is only available when

 

 

Details>Input>Config>Select>Input is set to RF.

 

 

 

 

Decoder

Query-only; displays the lock status of the decoder

Locked, Unlocked

 

Note: Decoder is only available when

 

 

Details>Input>Config>Select>Input is set to RF.

 

 

 

 

Transport

Query-only; displays the lock status of the transport stream

Locked, Unlocked

 

 

 

Rate

Query-only; displays the output rate for the QPSK demodulator

value in bps

 

 

 

22

01-0870-401B 01/03

Front Panel

Image 32
Contents TDR6 Electric Shock Hazard Contents Chapter Configuring the TDR6 Chapter TroubleshootingAppendix F Option Module Overview Appendix G Demodulator Application NotesUsing This Guide PrefaceLocating Information Important InformationIssuing Commands Front Panel NavigationDisplays RevisionLCD Display ErrorsCartons and Packing Materials SAA IMQOVE MitiUse Approved Attachments Only Viii 01-0870-401B 01/03 Overview Overview Overview 01-0870-401B 01/03 Ventilation Installing the TDR6AC Power Cords Connecting to a Power Source Power-up SequenceBasic TDR6 SD Configuration with No Option Modules Installed Connecting to a Remote Unit TMAC-6125 PortsConnecting to a Network Cabling the Analog Audio Connectors TDEC-6161 PortsLNB Power Cabling the TDEM-611001-0870-401B 01/03 Front Panel TDR6 Front PanelTDR6 DTV Receiver/Decoder Menu Structure LCD Display LCD Symbols LCD Text FormatsData a Menu Qpsk Key Character Displayed Correcting Mistakes Example QPSK, 8PSK, 16QAM Command Description Parameters / Response ValuesDVB DetailsInputConfigFilter allows you set the PCR filter Message No services available BERPID NTSC, PAL, AutoMPEG-2 Value, that does not begin with Important Considerations when entering Biss Ekey EIDControlEIA-232 used to configure the remote port MACRestoring a Default Configuration Restoring a User ConfigurationSaving a User Configuration Locking the Front PanelSetting the Date Setting the TimePerforming a System Reset Unlocking the Front PanelRemote Port Using a Remote UnitConfiguring Remote Software Parameters Command Types Ethernet PortBaud 01-0870-401B 01/03 TDR6 HD/SD Back Panel with Remote Designators Error Messages Explanation Action Required Informational Remote Commands ResponseDelay AutoChannelmode LangSample Rate Source MPEG-2, Atsc MPEG2VOL BissBiss Mode Biss StatusDC Autosel DC FilterDclock DmlockEbno LNBFaultlogclear Hdvd DelayRolloff 35RCRO, 25RCRO TuneMC Access Code MC Access FP RO, RWMC Access Unlock MC Config ListMC Default Restore Pgca AuthorizationPgca Mode MC Ethernet IP AddressPgca Timeout DataHandshake InterfaceVD Delay VBIVBI Control VBI FormatVD Mode PAL, NTSC, Auto VD SetupVD PID VD SubmodeQuick Start Configuring the TDR6Configuration Selecting a Service Detailed TDR6 Configuration Setting Local Date and TimeTDR6 Detailed Configuration Procedure Demodulator ConfigurationConfiguring the L-Band Carrier Frequency Parameter Front Panel Menu Remote Command Qpsk01-0870-401B 01/03 Troubleshooting Fault Reporting and MonitoringCurrent Faults Fault HistoryCommand Mnemonics Abbreviation Option Module Fault Descriptors are defined in the following table Viewing Current Faults Viewing the Fault History LogInput Status LED Not Illuminated Minimum E b /N 0 dBPerformance Problems Technical Specifications FACTORY-CONFIGURABLE FeaturesStandard Features Default Configurations Demodulator a DStandard-Definition Video Decoder High-Definition Video DecoderUser Data a B Remote ControlAudio Decoder a F Front Panel Access Ethernet01-0870-401B 01/03 Fault Relay Port Pin Specifications Port PinoutsNumber Synchronous Asynchronous Ethernet Port Pin Assignments Signal Signal DefinitionUser Data port Pin Specifications Standard RS232 Port Specifications TMAC-6125 SpecificationsTAUD-6100 Specifications TDEC-6100 SpecificationsTDEC-6161 Specifications TDEM-6110 Specifications LNB Port Specifications01-0870-401B 01/03 Tiernan VBI Data Transmission PALTiernan VBI Data Transmission Tiernan CC Mode is for Ntsc Format Only Tiernan Proprietary Closed Captions Tiernan CCDVB 422 Expanded Windows, 16-line and 32-line Lines Expanded Windows Field for an Encoded Picture Frame Front Panel Commands for Encoder Configuration Tiernan Closed Captions Front Panel CommandsRemote Commands for Encoder Configuration VE TCCVE Vbipass 32LINES01-0870-401B 01/03 Option Module Overview Typical Option ModuleOption Module Overview Demodulator Tuner SAW Filter Demodulator Application NotesIndustry Standard LNB Frequencies Information Rate SpacingOutput Spectrum Width Eb/N0 DefinitionMinimum and Maximum Information Rates TransponderEstimating Eb/N0 Using a Spectrum Analyzer Demodulator Low Eb/N0 AlarmEb/N0 Estimation Algorithm Spectrum AnalyzerDiagnostic Commands Offset = Actual RF Programmed RF Table Top and Rack Mount Installation Instructions Rear Rack Mount Instructions Rear Rack Bracket Mounting Instructions Fuse01-0870-401B 01/03 Index Index