JVC TDR6 installation and operation guide Value, that does not begin with

Page 36

Command

Description

 

Parameters / Response Values

 

 

 

Handshake

Sets the handshaking parameter for the user data port.

On: Enables handshaking for the specified

 

 

 

user data port

 

 

Off: Disables handshaking for the specified

 

 

 

user data port

 

 

 

Config Mode

Setting determines how the user data parameters are set.

Auto: TDR6 automatically configures the user

 

 

 

data parameters to match those of the

 

 

 

incoming transport stream

 

 

Manual: all user data parameters must be

 

 

 

manually set by the operator

 

 

 

Baud

Sets the baud rate for the data channel

Asynchronous: 1200, 2400, 4800, 9600,

 

 

 

19200, 38400

 

 

Synchronous: 0 - 4.096 Mbps

 

 

 

Data Bits

Sets the character length for the asynchronous data channel

7, 8

 

 

 

Parity

Sets the parity for the asynchronous data channel

None, Even, Odd

 

 

 

Stop Bits

Sets the number of stop bits for asynchronous data channel

1, 2

 

 

 

Details>VBI>Format: used to set the VBI parameters; for additional information on VBI, refer to the appendix on VBI data

transmission.

 

 

 

 

 

 

VBI Format

When VBI Fmt Cntrl is set to Auto, this parameter is query-only;

Off – no VBI information will be included in the

 

the TDR6 automatically detects and processes the incoming VBI

 

video output stream

 

data.

 

Note: VBI Fmt Cntrl must be set to manual for

 

When VBI Fmt Cntrl is set to Manual, this parameter is used to

 

this parameter to be set to off.

 

set the type of VBI format to be decoded and included in the

TiernanCC – sets the VBI format to Tiernan

 

video output stream.

 

proprietary closed captions

 

 

Lines16 – sets the VBI format to expanded

 

 

 

windows, 16 lines

 

 

Lines32 – sets the VBI format to expanded

 

 

 

windows, 32 lines

 

 

 

VBI Fmt Cntrl

Setting determines if the TDR6 will automatically detect, decode,

Auto – the TDR6 automatically determines the

 

and include the VBI data in the output stream, or if the user will

 

type of incoming VBI data, decodes it and

 

manually set all parameters.

 

includes it in the output stream

 

 

Manual – enables you to manually set the VBI

 

 

 

format to be decoded and included in the

 

 

 

video output stream.

 

 

 

 

Details>PGCA: queries the protection and authorization status of a signal

 

 

 

 

 

 

Status

Query-only; displays if the selected service is PGCA protected

PGCA_Enabled

 

 

In_the_Clear

 

 

 

 

Details>BISS: used to set the BISS mode and associated key and ID values. The key and ID values should be obtained from the site operator who has set-up the encryption at the encoder site.

The front panel numeric keypad has been enhanced to provide alpha-numeric entries for the 1KEY, EKEY, and EID parameter entries. For additional information on alpha-numeric entries, refer to the appropriate section in this supplement.

Status

Query-only; displays the state of the incoming transport stream.

Scrambled: the incoming transport stream is

 

 

scrambled

 

 

Not_scrambled: the incoming transport stream

 

 

is not scrambled

 

 

 

1Key

Sets the key value for BISS 1 mode. The 1Key value is also

The value is a 12 character hexadecimal

 

referred to as the clear session word.

value, that does not begin with 0x

 

Important Considerations when entering BISS 1KEY:

If less than 12 characters are entered, the

 

This command must be set before BISS Mode1 is set.

TDR6 will not set the command.

 

This command may not be entered/changed more than 10

If more than 12 characters are entered, the

 

times within a five minute time period.

TDR6 truncates the value to the first 12

 

When re-entering/changing this command, there must be at

characters entered.

 

 

 

least a 10 second time delay between entries.

 

 

The value cannot begin with the hex values 0x

 

 

The value cannot be displayed once it is entered. Instead, the

 

 

TDR6 will display 12 asterisks.

 

 

 

 

26

01-0870-401B 01/03

Front Panel

Image 36
Contents TDR6 Electric Shock Hazard Contents Chapter Configuring the TDR6 Chapter TroubleshootingAppendix F Option Module Overview Appendix G Demodulator Application NotesUsing This Guide PrefaceLocating Information Important InformationIssuing Commands Front Panel NavigationDisplays RevisionErrors Cartons and Packing MaterialsLCD Display SAA IMQOVE MitiUse Approved Attachments Only Viii 01-0870-401B 01/03 Overview Overview Overview 01-0870-401B 01/03 Installing the TDR6 AC Power CordsVentilation Connecting to a Power Source Power-up SequenceBasic TDR6 SD Configuration with No Option Modules Installed Connecting to a Remote Unit TMAC-6125 PortsConnecting to a Network Cabling the Analog Audio Connectors TDEC-6161 PortsLNB Power Cabling the TDEM-611001-0870-401B 01/03 Front Panel TDR6 Front PanelTDR6 DTV Receiver/Decoder Menu Structure LCD Display LCD Symbols LCD Text FormatsData a Menu Qpsk Key Character Displayed Correcting Mistakes Example Command Description Parameters / Response Values DVBQPSK, 8PSK, 16QAM DetailsInputConfigFilter allows you set the PCR filter Message No services available BERPID NTSC, PAL, AutoMPEG-2 Value, that does not begin with Important Considerations when entering Biss Ekey EIDControlEIA-232 used to configure the remote port MACRestoring a Default Configuration Restoring a User ConfigurationSaving a User Configuration Locking the Front PanelSetting the Date Setting the TimePerforming a System Reset Unlocking the Front PanelUsing a Remote Unit Configuring Remote Software ParametersRemote Port Command Types Ethernet PortBaud 01-0870-401B 01/03 TDR6 HD/SD Back Panel with Remote Designators Error Messages Explanation Action Required Informational Remote Commands ResponseDelay AutoChannelmode LangSample Rate Source MPEG-2, Atsc MPEG2VOL BissBiss Mode Biss StatusDC Autosel DC FilterDclock DmlockEbno LNBFaultlogclear Hdvd DelayRolloff 35RCRO, 25RCRO TuneMC Access Code MC Access FP RO, RWMC Access Unlock MC Config ListMC Default Restore Pgca AuthorizationPgca Mode MC Ethernet IP AddressPgca Timeout DataHandshake InterfaceVD Delay VBIVBI Control VBI FormatVD Mode PAL, NTSC, Auto VD SetupVD PID VD SubmodeConfiguring the TDR6 ConfigurationQuick Start Selecting a Service Detailed TDR6 Configuration Setting Local Date and TimeTDR6 Detailed Configuration Procedure Demodulator ConfigurationConfiguring the L-Band Carrier Frequency Parameter Front Panel Menu Remote Command Qpsk01-0870-401B 01/03 Troubleshooting Fault Reporting and MonitoringCurrent Faults Fault HistoryCommand Mnemonics Abbreviation Option Module Fault Descriptors are defined in the following table Viewing Current Faults Viewing the Fault History LogInput Status LED Not Illuminated Minimum E b /N 0 dBPerformance Problems Technical Specifications FACTORY-CONFIGURABLE FeaturesStandard Features Default Configurations Demodulator a DStandard-Definition Video Decoder High-Definition Video DecoderRemote Control Audio Decoder a FUser Data a B Front Panel Access Ethernet01-0870-401B 01/03 Fault Relay Port Pin Specifications Port PinoutsEthernet Port Pin Assignments Signal Signal Definition User Data port Pin Specifications Standard RS232Number Synchronous Asynchronous Port Specifications TMAC-6125 SpecificationsTDEC-6100 Specifications TDEC-6161 SpecificationsTAUD-6100 Specifications TDEM-6110 Specifications LNB Port Specifications01-0870-401B 01/03 Tiernan VBI Data Transmission PALTiernan VBI Data Transmission Tiernan CC Mode is for Ntsc Format Only Tiernan Proprietary Closed Captions Tiernan CCDVB 422 Expanded Windows, 16-line and 32-line Lines Expanded Windows Field for an Encoded Picture Frame Front Panel Commands for Encoder Configuration Tiernan Closed Captions Front Panel CommandsRemote Commands for Encoder Configuration VE TCCVE Vbipass 32LINES01-0870-401B 01/03 Option Module Overview Typical Option ModuleOption Module Overview Demodulator Application Notes Industry Standard LNB FrequenciesDemodulator Tuner SAW Filter Information Rate SpacingOutput Spectrum Width Eb/N0 DefinitionMinimum and Maximum Information Rates TransponderEstimating Eb/N0 Using a Spectrum Analyzer Demodulator Low Eb/N0 AlarmEb/N0 Estimation Algorithm Spectrum AnalyzerDiagnostic Commands Offset = Actual RF Programmed RF Table Top and Rack Mount Installation Instructions Rear Rack Mount Instructions Rear Rack Bracket Mounting Instructions Fuse01-0870-401B 01/03 Index Index