JVC installation and operation guide Installing the TDR6, Ventilation, AC Power Cords

Page 15

Installing the TDR6

2

This chapter provides step-by-step procedures for installing and cabling the TDR6.

DANGER!

Electric Shock

Hazard

CAUTION!

Please Read

Carefully

Do not remove the TDR6 top cover! The TDR6 is powered by an exposed, switching AC power supply which presents an electric shock hazard when the top cover is removed. Personal injury or damage to the equipment can occur when the top cover is removed. None of the procedures in this manual require the removal of the TDR6 top cover.

Before beginning your installation, read the Safety Precautions as they contain important safety information and other instructions required to install the TDR6.

Placement The TDR6 can be installed on a table top or in a rack. Use the following guidelines to determine the appropriate installation for your needs:

If the equipment must be moved frequently, install the TDR6 on a table top or other flat surface.

If the equipment is going to be installed permanently, install the TDR6 in a rack using rack mount brackets.

Whichever installation is used, always position the equipment to allow easy access to the rear panel and provide adequate ventilation.

To properly install the TDR6, follow the instructions provided in the appendix on table top and rack mount installation instructions.

Ventilation

The TDR6 must be positioned to receive adequate ventilation at all times. The cooling fan pulls air in through the side vents, circulates the air, and exhausts it out the side vents. The minimum air flow clearance required on both sides of the chassis is three (3) inches and six (6) inches for the rear panel.

Powering on the The rear panel AC power supply interface includes an On/Off (—/0) power switch TDR6 and an IEC 320 AC power cord receptacle. The maximum power supply output

for the TDR6 is 200 watts. The typical TDR6 configuration requires 100 watts.

The TDR6 is powered by an auto-sensing, auto-ranging AC switching power supply. The power supply accepts 100 to 240 VAC at 50 to 60 Hz.

AC Power Cords

The TDR6 shipping kit includes two AC power cords, one for North American applications, specifically the United States and Canada, and the other for international applications.

AC wiring must be done in accordance with governmental standards and codes in effect at the TDR6 installation site. Refer to the Safety Precautions for additional information.

CAUTION!

Please Read

Carefully

Installing the TDR6

01-0870-401B 01/03

5

Image 15
Contents TDR6 Electric Shock Hazard Contents Appendix G Demodulator Application Notes Chapter Configuring the TDR6Chapter Troubleshooting Appendix F Option Module OverviewImportant Information Using This GuidePreface Locating InformationRevision Issuing CommandsFront Panel Navigation DisplaysErrors Cartons and Packing MaterialsLCD Display Miti SAAIMQ OVEUse Approved Attachments Only Viii 01-0870-401B 01/03 Overview Overview Overview 01-0870-401B 01/03 Installing the TDR6 AC Power CordsVentilation Power-up Sequence Connecting to a Power SourceBasic TDR6 SD Configuration with No Option Modules Installed TMAC-6125 Ports Connecting to a Remote UnitConnecting to a Network TDEC-6161 Ports Cabling the Analog Audio ConnectorsCabling the TDEM-6110 LNB Power01-0870-401B 01/03 TDR6 Front Panel Front PanelTDR6 DTV Receiver/Decoder Menu Structure LCD Text Formats LCD Display LCD SymbolsData a Menu Qpsk Key Character Displayed Correcting Mistakes Example Command Description Parameters / Response Values DVBQPSK, 8PSK, 16QAM DetailsInputConfigFilter allows you set the PCR filter BER Message No services availableNTSC, PAL, Auto PIDMPEG-2 Value, that does not begin with EID Important Considerations when entering Biss EkeyMAC ControlEIA-232 used to configure the remote portLocking the Front Panel Restoring a Default ConfigurationRestoring a User Configuration Saving a User ConfigurationUnlocking the Front Panel Setting the DateSetting the Time Performing a System ResetUsing a Remote Unit Configuring Remote Software ParametersRemote Port Ethernet Port Command TypesBaud 01-0870-401B 01/03 TDR6 HD/SD Back Panel with Remote Designators Informational Remote Commands Response Error Messages Explanation Action RequiredLang DelayAuto ChannelmodeBiss Sample RateSource MPEG-2, Atsc MPEG2 VOLDC Filter Biss ModeBiss Status DC AutoselLNB DclockDmlock EbnoTune FaultlogclearHdvd Delay Rolloff 35RCRO, 25RCROMC Config List MC Access CodeMC Access FP RO, RW MC Access UnlockMC Ethernet IP Address MC Default RestorePgca Authorization Pgca ModeInterface Pgca TimeoutData HandshakeVBI Format VD DelayVBI VBI ControlVD Submode VD Mode PAL, NTSC, AutoVD Setup VD PIDConfiguring the TDR6 ConfigurationQuick Start Selecting a Service Demodulator Configuration Detailed TDR6 ConfigurationSetting Local Date and Time TDR6 Detailed Configuration ProcedureConfiguring the L-Band Carrier Frequency Qpsk Parameter Front Panel Menu Remote Command01-0870-401B 01/03 Fault History TroubleshootingFault Reporting and Monitoring Current FaultsCommand Mnemonics Abbreviation Option Module Fault Descriptors are defined in the following table Viewing the Fault History Log Viewing Current FaultsMinimum E b /N 0 dB Input Status LED Not IlluminatedPerformance Problems FACTORY-CONFIGURABLE Features Technical SpecificationsStandard Features High-Definition Video Decoder Default ConfigurationsDemodulator a D Standard-Definition Video DecoderRemote Control Audio Decoder a FUser Data a B Ethernet Front Panel Access01-0870-401B 01/03 Port Pinouts Fault Relay Port Pin SpecificationsEthernet Port Pin Assignments Signal Signal Definition User Data port Pin Specifications Standard RS232Number Synchronous Asynchronous TMAC-6125 Specifications Port SpecificationsTDEC-6100 Specifications TDEC-6161 SpecificationsTAUD-6100 Specifications LNB Port Specifications TDEM-6110 Specifications01-0870-401B 01/03 PAL Tiernan VBI Data TransmissionTiernan VBI Data Transmission Tiernan Proprietary Closed Captions Tiernan CC Tiernan CC Mode is for Ntsc Format OnlyDVB 422 Expanded Windows, 16-line and 32-line Lines Expanded Windows Field for an Encoded Picture Frame Tiernan Closed Captions Front Panel Commands Front Panel Commands for Encoder Configuration32LINES Remote Commands for Encoder ConfigurationVE TCC VE Vbipass01-0870-401B 01/03 Typical Option Module Option Module OverviewOption Module Overview Demodulator Application Notes Industry Standard LNB FrequenciesDemodulator Tuner SAW Filter Spacing Information RateTransponder Output Spectrum WidthEb/N0 Definition Minimum and Maximum Information RatesSpectrum Analyzer Estimating Eb/N0 Using a Spectrum AnalyzerDemodulator Low Eb/N0 Alarm Eb/N0 Estimation AlgorithmDiagnostic Commands Offset = Actual RF Programmed RF Table Top and Rack Mount Installation Instructions Rear Rack Mount Instructions Fuse Rear Rack Bracket Mounting Instructions01-0870-401B 01/03 Index Index