JVC TDR6 Dclock, Dmlock, Ebno, Lnb, MOD QPSK, 8PSK, 16QAM Qpsk, Offset, Rawber

Page 50

TDR6 Remote Command Listing (continued)

Mnemonics

Parameters/

DVB Defaults

 

Description

Response Values

 

 

 

 

 

 

 

 

 

 

 

 

DMD.x

 

Where x is A, B, C, or D

 

Combined with additional mnemonics, specifies the

 

 

and designates the

 

 

demodulator that is the object of the command.

 

 

demodulator to be

 

 

For example, if RF output B is currently active, the DMD.B

 

 

configured or queried.

 

 

DMLOCK command displays the current lock status of

 

 

 

 

 

demodulator B.

 

 

 

 

 

By itself, queries all parameters of specified

 

 

 

 

 

demodulator.When DMD.x is entered, the TDR6 returns the

 

 

 

 

 

following information for the designated channel: Eb/No,

 

 

 

 

 

locked status for the decoder and demodulator, offset,

 

 

 

 

 

modulation type, LO frequency, RF frequency, data rate,

 

 

 

 

 

symbol rate, code rate, LNB power, and rolloff setting.

 

 

 

 

 

Commands for all demodulator ports are the same.

 

 

 

 

 

Front panel equivalent: None

 

 

 

 

 

 

DMD.x

BER

 

Query-only; displays the bit error rate; this value represents

 

 

 

 

 

the number of errors detected in the signal after error

 

 

 

 

 

correction is applied. This rate should be a zero for correct

 

 

 

 

 

performance.

 

 

 

 

 

 

DMD.x

CR

1/2, 2/3, 3/4, 5/6, 7/8, 8/9

5/6

 

Sets the Viterbi code rate for the designated demodulator.

 

 

 

 

 

Front panel equivalent:

 

 

 

 

 

Details>Input>Config>Demod>RF>Code Rate

 

 

 

 

 

 

DMD.x

DCLOCK

locked, unlocked

 

Query-only; displays the locked status of the decoder to the

 

 

 

 

 

incoming signal.

 

 

 

 

 

Front panel equivalent: Details>Input Status>Decoder

 

 

 

 

 

 

DMD.x

DMLOCK

locked, unlocked

 

Query-only; displays the locked status of the demodulator

 

 

 

 

 

to the incoming signal.

 

 

 

 

 

Front panel equivalent: Details>Input>Status>Demod

 

 

 

 

 

 

DMD.x

DR

1000000 to 100000000

8448000

 

Sets the value for the incoming demodulated data rate for

 

 

bps

 

 

the designated demodulator.

 

 

 

 

 

Front panel equivalent:

 

 

 

 

 

Details>Input>Config>Demod>RF>Data Rate

 

 

 

 

 

 

DMD.x

EBNO

-99 to 99 dB

 

Query-only; displays the energy per bit over the noise ratio

 

 

 

 

 

of the signal after Viterbi decoding and before Reed-

 

 

 

 

 

Solomon decoding for the designated demodulator.

 

 

 

 

 

Front panel equivalent: Details>Input>Status>Eb/No

 

 

 

 

 

 

DMD.x

LNB

OFF, 13V, 18V

Off

 

Sets the output DC voltage to power the antenna’s low

 

 

 

 

 

noise block amp and defines polarization for the designated

 

 

 

 

 

demodulator.

 

 

 

 

 

Front panel equivalent:

 

 

 

 

 

Details>Input>Config>Demod>RF>LNB Power

 

 

 

 

 

 

DMD.x

LO

0 to 15000 MHz

10000

 

Sets an internal representation of the local oscillator

 

 

 

 

 

frequency of the external down converter for the designated

 

 

 

 

 

demodulator.

 

 

 

 

 

Front panel equivalent:

 

 

 

 

 

Details>Input>Config>Demod>RF>LO Frequency

 

 

 

 

 

 

DMD.x

MOD

QPSK, 8PSK, 16QAM

QPSK

 

Sets the modulation type for the decoder.

 

 

 

 

 

Front panel equivalent:

 

 

 

 

 

Details>Input>Config>Demod>RF>Modulation

 

 

 

 

 

 

DMD.x

OFFSET

 

Query-only; displays the difference between the frequency

 

 

 

 

 

set by the user and the frequency actually locked onto.

 

 

 

 

 

Front panel equivalent: None

 

 

 

 

 

 

DMD.x

RAWBER

 

Query-only; displays the raw bit error rate; this rate is the

 

 

 

 

 

error rate of the signal as it is received from the satellite,

 

 

 

 

 

before error correction is applied.

 

 

 

 

 

 

40

01-0870-401B 01/03

Using a Remote Unit

Image 50
Contents TDR6 Electric Shock Hazard Contents Appendix F Option Module Overview Chapter Configuring the TDR6Chapter Troubleshooting Appendix G Demodulator Application NotesLocating Information Using This GuidePreface Important InformationDisplays Issuing CommandsFront Panel Navigation RevisionLCD Display ErrorsCartons and Packing Materials OVE SAAIMQ MitiUse Approved Attachments Only Viii 01-0870-401B 01/03 Overview Overview Overview 01-0870-401B 01/03 Ventilation Installing the TDR6AC Power Cords Connecting to a Power Source Power-up SequenceBasic TDR6 SD Configuration with No Option Modules Installed Connecting to a Remote Unit TMAC-6125 PortsConnecting to a Network Cabling the Analog Audio Connectors TDEC-6161 PortsLNB Power Cabling the TDEM-611001-0870-401B 01/03 Front Panel TDR6 Front PanelTDR6 DTV Receiver/Decoder Menu Structure LCD Display LCD Symbols LCD Text FormatsData a Menu Qpsk Key Character Displayed Correcting Mistakes Example QPSK, 8PSK, 16QAM Command Description Parameters / Response ValuesDVB DetailsInputConfigFilter allows you set the PCR filter Message No services available BERPID NTSC, PAL, AutoMPEG-2 Value, that does not begin with Important Considerations when entering Biss Ekey EIDControlEIA-232 used to configure the remote port MACSaving a User Configuration Restoring a Default ConfigurationRestoring a User Configuration Locking the Front PanelPerforming a System Reset Setting the DateSetting the Time Unlocking the Front PanelRemote Port Using a Remote UnitConfiguring Remote Software Parameters Command Types Ethernet PortBaud 01-0870-401B 01/03 TDR6 HD/SD Back Panel with Remote Designators Error Messages Explanation Action Required Informational Remote Commands ResponseChannelmode DelayAuto LangVOL Sample RateSource MPEG-2, Atsc MPEG2 BissDC Autosel Biss ModeBiss Status DC FilterEbno DclockDmlock LNBRolloff 35RCRO, 25RCRO FaultlogclearHdvd Delay TuneMC Access Unlock MC Access CodeMC Access FP RO, RW MC Config ListPgca Mode MC Default RestorePgca Authorization MC Ethernet IP AddressHandshake Pgca TimeoutData InterfaceVBI Control VD DelayVBI VBI FormatVD PID VD Mode PAL, NTSC, AutoVD Setup VD SubmodeQuick Start Configuring the TDR6Configuration Selecting a Service TDR6 Detailed Configuration Procedure Detailed TDR6 ConfigurationSetting Local Date and Time Demodulator ConfigurationConfiguring the L-Band Carrier Frequency Parameter Front Panel Menu Remote Command Qpsk01-0870-401B 01/03 Current Faults TroubleshootingFault Reporting and Monitoring Fault HistoryCommand Mnemonics Abbreviation Option Module Fault Descriptors are defined in the following table Viewing Current Faults Viewing the Fault History LogInput Status LED Not Illuminated Minimum E b /N 0 dBPerformance Problems Technical Specifications FACTORY-CONFIGURABLE FeaturesStandard Features Standard-Definition Video Decoder Default ConfigurationsDemodulator a D High-Definition Video DecoderUser Data a B Remote ControlAudio Decoder a F Front Panel Access Ethernet01-0870-401B 01/03 Fault Relay Port Pin Specifications Port PinoutsNumber Synchronous Asynchronous Ethernet Port Pin Assignments Signal Signal DefinitionUser Data port Pin Specifications Standard RS232 Port Specifications TMAC-6125 SpecificationsTAUD-6100 Specifications TDEC-6100 SpecificationsTDEC-6161 Specifications TDEM-6110 Specifications LNB Port Specifications01-0870-401B 01/03 Tiernan VBI Data Transmission PALTiernan VBI Data Transmission Tiernan CC Mode is for Ntsc Format Only Tiernan Proprietary Closed Captions Tiernan CCDVB 422 Expanded Windows, 16-line and 32-line Lines Expanded Windows Field for an Encoded Picture Frame Front Panel Commands for Encoder Configuration Tiernan Closed Captions Front Panel CommandsVE Vbipass Remote Commands for Encoder ConfigurationVE TCC 32LINES01-0870-401B 01/03 Option Module Overview Typical Option ModuleOption Module Overview Demodulator Tuner SAW Filter Demodulator Application NotesIndustry Standard LNB Frequencies Information Rate SpacingMinimum and Maximum Information Rates Output Spectrum WidthEb/N0 Definition TransponderEb/N0 Estimation Algorithm Estimating Eb/N0 Using a Spectrum AnalyzerDemodulator Low Eb/N0 Alarm Spectrum AnalyzerDiagnostic Commands Offset = Actual RF Programmed RF Table Top and Rack Mount Installation Instructions Rear Rack Mount Instructions Rear Rack Bracket Mounting Instructions Fuse01-0870-401B 01/03 Index Index