JVC TDR6 Error Messages Explanation Action Required, Informational Remote Commands Response

Page 46

Error Messages If the TDR6 is not able to execute a command, an error message will be returned, indicating the command was not completed. TDR6 error messages, along with the action required to resolve the error, are explained in the following table.

Error Messages

Message

Explanation

Action Required

 

 

 

Error

The TDR6 was unable to execute the

Repeat the requested command. If the command

 

requested command. This is a

still results in an error message, check the

 

summary error, which may indicate a

configuration of the unit and repeat the command.

 

hardware failure or configuration

If an error results, reset the unit and attempt the

 

abnormality.

command again. If you are unable to execute the

 

 

command, contact Customer Service.

 

 

 

Format Error

The command syntax was entered

Re-enter the command using the proper syntax

 

incorrectly.

and format.

 

 

 

Parameter Error

The TDR6 does not recognize the

Re-enter the command using the correct

 

parameter. A numerical parameter may

parameter.

 

be out of range, or an ASCII character

 

 

string may not match any of the

 

 

available parameters for the command.

 

 

 

 

Not Supported

The requested command does not

Review the lists of commands to ensure that you

 

match any valid TDR6 command.

entered a valid command.

In addition to the actions listed in the error messages table, you can also enter the following types of commands to receive additional information when errors are encountered or additional information is needed.

Informational Remote Commands

Response

 

 

<mnemonic>

Displays system information associated

For example: ADA

with that command.

 

 

<mnemonic> <instruction> ?

Lists information available for that

For example: MC RS232 BAUD ?

particular command, including all valid

 

parameters

 

 

Command The standard TDR6 remote commands are listed in the following table, which Descriptions provides the following information:

NOTE

Remote command mnemonic

Parameter values or command response values

Factory DVB-compliant default value

Description of the command, including parameter definitions and the front panel command equivalent

Commands used to set a parameter may also be used to query the current command. Use the command mnemonic without a parameter and the TDR6 will return the current parameter setting.

The specific commands available depend on the option modules installed in your TDR6.

36

01-0870-401B 01/03

Using a Remote Unit

Image 46
Contents TDR6 Electric Shock Hazard Contents Appendix F Option Module Overview Chapter Configuring the TDR6Chapter Troubleshooting Appendix G Demodulator Application NotesLocating Information Using This GuidePreface Important InformationDisplays Issuing CommandsFront Panel Navigation RevisionCartons and Packing Materials ErrorsLCD Display OVE SAAIMQ MitiUse Approved Attachments Only Viii 01-0870-401B 01/03 Overview Overview Overview 01-0870-401B 01/03 AC Power Cords Installing the TDR6Ventilation Connecting to a Power Source Power-up SequenceBasic TDR6 SD Configuration with No Option Modules Installed Connecting to a Remote Unit TMAC-6125 PortsConnecting to a Network Cabling the Analog Audio Connectors TDEC-6161 PortsLNB Power Cabling the TDEM-611001-0870-401B 01/03 Front Panel TDR6 Front PanelTDR6 DTV Receiver/Decoder Menu Structure LCD Display LCD Symbols LCD Text FormatsData a Menu Qpsk Key Character Displayed Correcting Mistakes Example DVB Command Description Parameters / Response ValuesQPSK, 8PSK, 16QAM DetailsInputConfigFilter allows you set the PCR filter Message No services available BERPID NTSC, PAL, AutoMPEG-2 Value, that does not begin with Important Considerations when entering Biss Ekey EIDControlEIA-232 used to configure the remote port MACSaving a User Configuration Restoring a Default ConfigurationRestoring a User Configuration Locking the Front PanelPerforming a System Reset Setting the DateSetting the Time Unlocking the Front PanelConfiguring Remote Software Parameters Using a Remote UnitRemote Port Command Types Ethernet PortBaud 01-0870-401B 01/03 TDR6 HD/SD Back Panel with Remote Designators Error Messages Explanation Action Required Informational Remote Commands ResponseChannelmode DelayAuto LangVOL Sample RateSource MPEG-2, Atsc MPEG2 BissDC Autosel Biss ModeBiss Status DC FilterEbno DclockDmlock LNBRolloff 35RCRO, 25RCRO FaultlogclearHdvd Delay TuneMC Access Unlock MC Access CodeMC Access FP RO, RW MC Config ListPgca Mode MC Default RestorePgca Authorization MC Ethernet IP AddressHandshake Pgca TimeoutData InterfaceVBI Control VD DelayVBI VBI FormatVD PID VD Mode PAL, NTSC, AutoVD Setup VD SubmodeConfiguration Configuring the TDR6Quick Start Selecting a Service TDR6 Detailed Configuration Procedure Detailed TDR6 ConfigurationSetting Local Date and Time Demodulator ConfigurationConfiguring the L-Band Carrier Frequency Parameter Front Panel Menu Remote Command Qpsk01-0870-401B 01/03 Current Faults TroubleshootingFault Reporting and Monitoring Fault HistoryCommand Mnemonics Abbreviation Option Module Fault Descriptors are defined in the following table Viewing Current Faults Viewing the Fault History LogInput Status LED Not Illuminated Minimum E b /N 0 dBPerformance Problems Technical Specifications FACTORY-CONFIGURABLE FeaturesStandard Features Standard-Definition Video Decoder Default ConfigurationsDemodulator a D High-Definition Video DecoderAudio Decoder a F Remote ControlUser Data a B Front Panel Access Ethernet01-0870-401B 01/03 Fault Relay Port Pin Specifications Port PinoutsUser Data port Pin Specifications Standard RS232 Ethernet Port Pin Assignments Signal Signal DefinitionNumber Synchronous Asynchronous Port Specifications TMAC-6125 SpecificationsTDEC-6161 Specifications TDEC-6100 SpecificationsTAUD-6100 Specifications TDEM-6110 Specifications LNB Port Specifications01-0870-401B 01/03 Tiernan VBI Data Transmission PALTiernan VBI Data Transmission Tiernan CC Mode is for Ntsc Format Only Tiernan Proprietary Closed Captions Tiernan CCDVB 422 Expanded Windows, 16-line and 32-line Lines Expanded Windows Field for an Encoded Picture Frame Front Panel Commands for Encoder Configuration Tiernan Closed Captions Front Panel CommandsVE Vbipass Remote Commands for Encoder ConfigurationVE TCC 32LINES01-0870-401B 01/03 Option Module Overview Typical Option ModuleOption Module Overview Industry Standard LNB Frequencies Demodulator Application NotesDemodulator Tuner SAW Filter Information Rate SpacingMinimum and Maximum Information Rates Output Spectrum WidthEb/N0 Definition TransponderEb/N0 Estimation Algorithm Estimating Eb/N0 Using a Spectrum AnalyzerDemodulator Low Eb/N0 Alarm Spectrum AnalyzerDiagnostic Commands Offset = Actual RF Programmed RF Table Top and Rack Mount Installation Instructions Rear Rack Mount Instructions Rear Rack Bracket Mounting Instructions Fuse01-0870-401B 01/03 Index Index