JVC TDR6 installation and operation guide Important Considerations when entering Biss Ekey, Eid

Page 37

Command

Description

Parameters / Response Values

 

 

 

EKey

Sets the key value for BISS E mode. The E key value is also

The value is a 16 character hexadecimal

 

referred to as the encrypted session word.

value, that does not begin with 0x

 

Important Considerations when entering BISS EKEY:

If less than 16 characters are entered, the

 

This command must be set before BISS ModeE is set.

TDR6 will not set the command.

 

This command may not be entered/changed more than 10

If more than 16 characters are entered, the

 

times within a five minute time period.

TDR6 truncates the value to the first 16

 

When re-entering/changing this command, there must be at

characters entered.

 

 

 

least a 10 second time delay between entries.

 

 

The value cannot begin with the hex values 0x

 

 

The value cannot be displayed once it is entered. Instead, the

 

 

TDR6 will display 16 asterisks.

 

 

 

 

EID

Sets the identification value for BISS E mode. The E ID value is

The value is a 14 character hexadecimal

 

also referred to as the Injected ID.

value, that does not begin with 0x

 

Important Considerations when entering BISS EID:

If less than 12 characters are entered, the

 

This command must be set before BISS ModeE is set.

TDR6 will not set the command.

 

This command may not be entered/changed more than 10

If more than 14 characters are entered, the

 

times within a five minute time period.

TDR6 truncates the value to the first 14

 

When re-entering/changing this command, there must be at

characters entered.

 

 

 

least a 10 second time delay between entries.

 

 

The value cannot begin with the hex values 0x

 

 

The value cannot be displayed once it is entered. Instead, the

 

 

TDR6 will display 14 asterisks.

 

 

 

 

BISS Mode

Sets the BISS mode that will be used to descramble the

none, mode1, modee

 

incoming transport stream.

Default: none

 

Note: Before setting this command to mode1 or modeE, the

 

 

appropriate KEY and ID values must first be entered.

 

 

Note: There may be a slight delay in the picture when setting or

 

 

changing BISS modes. This occurs when the signal is routed to

 

 

the descrambling module.

 

 

Note: To ensure proper BISS operations, ensure that PGCA is

 

 

set to Off.

 

 

 

 

Faults Menu: consists of three submenus: Current, History, and Clear, which are used to view current faults and fault history log and to clear the fault history log.

The TDR6 performs fault detection and reporting on a real- time basis. When the TDR6 detects a fault, a description of the fault is reported to the current fault log. The fault is also reported to the fault history log, where it is stored.

The status of the TDR6 can be quickly determined by checking the front panel LEDs. If any fault LEDs are illuminated, the TDR6 can be queried for additional information using the Faults menu.

Current

Query-only; displays the current fault log. The current fault log

Displays a list of current faults

 

only retains and reports fault conditions present at the time of the

 

 

fault query; prior fault conditions are not retained or reported

 

 

here. Current faults are reported in order of occurrence,

 

 

beginning with the most recent.

 

 

 

 

History

Query-only; displays the fault history log. The fault history log

Displays a list of faults stored in the fault history

 

retains all faults that have occurred since the TDR6 was

log; faults are time stamped.

 

powered on, the TDR6 was reset, or the fault history log was

 

 

cleared.

 

 

Faults are time stamped, using the TDR6 internal clock, to help

 

 

you monitor system performance and diagnose problems. Faults

 

 

are listed in order of occurrence, beginning with the most recent.

 

 

 

 

Clear

Clears the fault history log. The fault history log is also cleared

After faults are cleared, LCD displays Fault menu

 

when the TDR6 is reset or powered-off.

 

 

 

 

Control Menu: allows you to control the TDR6 hardware; submenus are FP_Lock, EIA-232, Network, Clock, and Reset.

 

 

Control>FP_Lock: used to query and change the status of the front panel

 

 

 

 

State

Sets the state of the front panel

Locked – disables the front panel; the front

 

 

panel can only be used to view status and

 

 

configuration parameters

 

 

Normal – the front panel is unlocked and can

 

 

be used to enter and change configuration

 

 

parameters (default)

 

 

 

Password = 0

Unlocks the front panel; used in conjunction with the state

7384 (default)

 

command. Password = 0 is only displayed when the front

 

 

panel is set to locked

 

 

 

 

Front Panel

01-0870-401B 01/03

27

Image 37
Contents TDR6 Electric Shock Hazard Contents Chapter Troubleshooting Chapter Configuring the TDR6Appendix F Option Module Overview Appendix G Demodulator Application NotesPreface Using This GuideLocating Information Important InformationFront Panel Navigation Issuing CommandsDisplays RevisionCartons and Packing Materials ErrorsLCD Display IMQ SAAOVE MitiUse Approved Attachments Only Viii 01-0870-401B 01/03 Overview Overview Overview 01-0870-401B 01/03 AC Power Cords Installing the TDR6Ventilation Power-up Sequence Connecting to a Power SourceBasic TDR6 SD Configuration with No Option Modules Installed TMAC-6125 Ports Connecting to a Remote UnitConnecting to a Network TDEC-6161 Ports Cabling the Analog Audio ConnectorsCabling the TDEM-6110 LNB Power01-0870-401B 01/03 TDR6 Front Panel Front PanelTDR6 DTV Receiver/Decoder Menu Structure LCD Text Formats LCD Display LCD SymbolsData a Menu Qpsk Key Character Displayed Correcting Mistakes Example DVB Command Description Parameters / Response ValuesQPSK, 8PSK, 16QAM DetailsInputConfigFilter allows you set the PCR filter BER Message No services availableNTSC, PAL, Auto PIDMPEG-2 Value, that does not begin with EID Important Considerations when entering Biss EkeyMAC ControlEIA-232 used to configure the remote portRestoring a User Configuration Restoring a Default ConfigurationSaving a User Configuration Locking the Front PanelSetting the Time Setting the DatePerforming a System Reset Unlocking the Front PanelConfiguring Remote Software Parameters Using a Remote UnitRemote Port Ethernet Port Command TypesBaud 01-0870-401B 01/03 TDR6 HD/SD Back Panel with Remote Designators Informational Remote Commands Response Error Messages Explanation Action RequiredAuto DelayChannelmode LangSource MPEG-2, Atsc MPEG2 Sample RateVOL BissBiss Status Biss ModeDC Autosel DC FilterDmlock DclockEbno LNBHdvd Delay FaultlogclearRolloff 35RCRO, 25RCRO TuneMC Access FP RO, RW MC Access CodeMC Access Unlock MC Config ListPgca Authorization MC Default RestorePgca Mode MC Ethernet IP AddressData Pgca TimeoutHandshake InterfaceVBI VD DelayVBI Control VBI FormatVD Setup VD Mode PAL, NTSC, AutoVD PID VD SubmodeConfiguration Configuring the TDR6Quick Start Selecting a Service Setting Local Date and Time Detailed TDR6 ConfigurationTDR6 Detailed Configuration Procedure Demodulator ConfigurationConfiguring the L-Band Carrier Frequency Qpsk Parameter Front Panel Menu Remote Command01-0870-401B 01/03 Fault Reporting and Monitoring TroubleshootingCurrent Faults Fault HistoryCommand Mnemonics Abbreviation Option Module Fault Descriptors are defined in the following table Viewing the Fault History Log Viewing Current FaultsMinimum E b /N 0 dB Input Status LED Not IlluminatedPerformance Problems FACTORY-CONFIGURABLE Features Technical SpecificationsStandard Features Demodulator a D Default ConfigurationsStandard-Definition Video Decoder High-Definition Video DecoderAudio Decoder a F Remote ControlUser Data a B Ethernet Front Panel Access01-0870-401B 01/03 Port Pinouts Fault Relay Port Pin SpecificationsUser Data port Pin Specifications Standard RS232 Ethernet Port Pin Assignments Signal Signal DefinitionNumber Synchronous Asynchronous TMAC-6125 Specifications Port SpecificationsTDEC-6161 Specifications TDEC-6100 SpecificationsTAUD-6100 Specifications LNB Port Specifications TDEM-6110 Specifications01-0870-401B 01/03 PAL Tiernan VBI Data TransmissionTiernan VBI Data Transmission Tiernan Proprietary Closed Captions Tiernan CC Tiernan CC Mode is for Ntsc Format OnlyDVB 422 Expanded Windows, 16-line and 32-line Lines Expanded Windows Field for an Encoded Picture Frame Tiernan Closed Captions Front Panel Commands Front Panel Commands for Encoder ConfigurationVE TCC Remote Commands for Encoder ConfigurationVE Vbipass 32LINES01-0870-401B 01/03 Typical Option Module Option Module OverviewOption Module Overview Industry Standard LNB Frequencies Demodulator Application NotesDemodulator Tuner SAW Filter Spacing Information RateEb/N0 Definition Output Spectrum WidthMinimum and Maximum Information Rates TransponderDemodulator Low Eb/N0 Alarm Estimating Eb/N0 Using a Spectrum AnalyzerEb/N0 Estimation Algorithm Spectrum AnalyzerDiagnostic Commands Offset = Actual RF Programmed RF Table Top and Rack Mount Installation Instructions Rear Rack Mount Instructions Fuse Rear Rack Bracket Mounting Instructions01-0870-401B 01/03 Index Index