JVC TDR6 MC Default Restore, MC Ethernet IP Address, Gateway, MC Ethernet IP MAC, MC HW Opts

Page 53

TDR6 Remote Command Listing (continued)

Mnemonics

Parameters/

DVB Defaults

 

Description

Response Values

 

 

 

 

 

 

 

 

 

 

MC DEFAULT RESTORE

where <string> = DVB,

 

Resets the TDR6 with the specified factory-default operating

<string>

Default1, Default2, and

 

 

configuration.

 

Default3

 

 

For more information on configurations, refer to the

 

 

 

 

configuration chapter.

 

 

 

 

Front panel equivalent: Config>Default>Restore

 

 

 

 

 

MC ETHERNET IP ADDRESS

<x.x.x.x> where each x

 

Sets the ethernet IP address for the TDR6. Example:

 

represents a decimal

 

 

192.200.9.201

 

number from 0 to 255

 

 

Front panel equivalent: Control>Network>Address

 

 

 

 

 

MC ETHERNET IP

<x.x.x.x> where each x

0.0.0.0

 

Sets the IP gateway address.

GATEWAY

represents a decimal

 

 

Front panel equivalent: Control>Network>Gateway

 

number from 0 to 255

 

 

 

 

 

 

 

 

MC ETHERNET IP MAC

Format:

 

Sets the Ethernet hardware address.

 

<xx:xx:xx:xx:xx:xx>

 

 

For example: 00:e0:74:00:02:cb

 

where xx is a

 

 

 

 

hexadecimal number

 

 

 

 

from 0 to f.

 

 

 

 

 

 

 

MC ETHERNET IP MASK

<x.x.x.x> where each x

255.255.255.0

Sets the IP address mask (IP subnet mask).

 

represents a decimal

 

 

Front panel equivalent: Control>Network>Mask

 

number from 0 to 255

 

 

 

 

 

 

 

 

MC HW OPTS

 

Query-only; displays the optional hardware installed on the

 

 

 

 

controller card.

 

 

 

 

Front panel equivalent: None

 

 

 

 

 

MC HW TYPE

 

Query-only; displays the type of decoder hardware.

 

 

 

 

Front panel equivalent: None

 

 

 

 

 

MC RS232 BAUD

1200, 2400, 4800, 9600,

38400

 

Sets the baud rate for the remote port.

 

19200, 38400

 

 

Front panel equivalent: Control>EIA-232>Baud

 

 

 

 

 

MC RS232 DATA

7, 8

8

 

Sets the data bits for the remote port.

 

 

 

 

Front panel equivalent: Control>EIA-232>Data Bits

 

 

 

 

 

MC RS232 HARDFLOW

On, Off

On

 

On: sets data flow to be controlled by hardware

 

 

 

 

Off: permits data flow to be controlled by hardware

 

 

 

 

Front panel equivalent: Control>EIA-232>Hard Flow

 

 

 

 

 

MC RS232 PARITY

None, Odd, Even

None

 

Sets the parity for the remote port.

 

 

 

 

Front panel equivalent: Control>EIA-232>Parity

 

 

 

 

 

MC RS232 SOFTFLOW

On, Off

Off

 

On: sets data flow to be controlled by software

 

 

 

 

Off: permits data flow to be controlled by software

 

 

 

 

Front panel equivalent: Control>EIA-232>Soft Flow

 

 

 

 

 

MC RS232 STOP

1, 2

1

 

Sets the stop bits for the remote port.

 

 

 

 

Front panel equivalent: Control>EIA-232>Stop Bits

 

 

 

 

 

MC SW

 

Query-only; displays the installed software version.

 

 

 

 

Front panel equivalent: Version

 

 

 

 

 

PGCA

 

When PGCA is entered, the TDR6 returns the following

 

 

 

 

conditional access information: mode, status, authorization,

 

 

 

 

and time-out

 

 

 

 

Front panel equivalent: None

 

 

 

 

 

PGCA AUTHORIZATION

Yes, No, N/A

 

Query-only; displays whether the originator of the service

 

 

 

 

has authorized your TDR6 to receive the selected service.

 

 

 

 

Front panel equivalent: Details>PGCA>Authorization

 

 

 

 

 

PGCA MODE

Auto

Auto

 

Sets the TDR6 to automatically receive authorized PGCA-

 

 

 

 

protected signals.

 

 

 

 

Front panel equivalent: None

 

 

 

 

 

PGCA STATUS

In_the_Clear,

 

Query-only; displays whether or not a signal is PGCA

 

PGCA_Enabled

 

 

protected.

 

 

 

 

Front panel equivalent: Details>PGCA>Status

 

 

 

 

 

Using a Remote Unit

01-0870-401B 01/03

43

Image 53
Contents TDR6 Electric Shock Hazard Contents Chapter Troubleshooting Chapter Configuring the TDR6Appendix F Option Module Overview Appendix G Demodulator Application NotesPreface Using This GuideLocating Information Important InformationFront Panel Navigation Issuing CommandsDisplays RevisionLCD Display ErrorsCartons and Packing Materials IMQ SAAOVE MitiUse Approved Attachments Only Viii 01-0870-401B 01/03 Overview Overview Overview 01-0870-401B 01/03 Ventilation Installing the TDR6AC Power Cords Power-up Sequence Connecting to a Power SourceBasic TDR6 SD Configuration with No Option Modules Installed TMAC-6125 Ports Connecting to a Remote UnitConnecting to a Network TDEC-6161 Ports Cabling the Analog Audio ConnectorsCabling the TDEM-6110 LNB Power01-0870-401B 01/03 TDR6 Front Panel Front PanelTDR6 DTV Receiver/Decoder Menu Structure LCD Text Formats LCD Display LCD SymbolsData a Menu Qpsk Key Character Displayed Correcting Mistakes Example QPSK, 8PSK, 16QAM Command Description Parameters / Response ValuesDVB DetailsInputConfigFilter allows you set the PCR filter BER Message No services availableNTSC, PAL, Auto PIDMPEG-2 Value, that does not begin with EID Important Considerations when entering Biss EkeyMAC ControlEIA-232 used to configure the remote portRestoring a User Configuration Restoring a Default ConfigurationSaving a User Configuration Locking the Front PanelSetting the Time Setting the DatePerforming a System Reset Unlocking the Front PanelRemote Port Using a Remote UnitConfiguring Remote Software Parameters Ethernet Port Command TypesBaud 01-0870-401B 01/03 TDR6 HD/SD Back Panel with Remote Designators Informational Remote Commands Response Error Messages Explanation Action RequiredAuto DelayChannelmode LangSource MPEG-2, Atsc MPEG2 Sample RateVOL BissBiss Status Biss ModeDC Autosel DC FilterDmlock DclockEbno LNBHdvd Delay FaultlogclearRolloff 35RCRO, 25RCRO TuneMC Access FP RO, RW MC Access CodeMC Access Unlock MC Config ListPgca Authorization MC Default RestorePgca Mode MC Ethernet IP AddressData Pgca TimeoutHandshake InterfaceVBI VD DelayVBI Control VBI FormatVD Setup VD Mode PAL, NTSC, AutoVD PID VD SubmodeQuick Start Configuring the TDR6Configuration Selecting a Service Setting Local Date and Time Detailed TDR6 ConfigurationTDR6 Detailed Configuration Procedure Demodulator ConfigurationConfiguring the L-Band Carrier Frequency Qpsk Parameter Front Panel Menu Remote Command01-0870-401B 01/03 Fault Reporting and Monitoring TroubleshootingCurrent Faults Fault HistoryCommand Mnemonics Abbreviation Option Module Fault Descriptors are defined in the following table Viewing the Fault History Log Viewing Current FaultsMinimum E b /N 0 dB Input Status LED Not IlluminatedPerformance Problems FACTORY-CONFIGURABLE Features Technical SpecificationsStandard Features Demodulator a D Default ConfigurationsStandard-Definition Video Decoder High-Definition Video DecoderUser Data a B Remote ControlAudio Decoder a F Ethernet Front Panel Access01-0870-401B 01/03 Port Pinouts Fault Relay Port Pin SpecificationsNumber Synchronous Asynchronous Ethernet Port Pin Assignments Signal Signal DefinitionUser Data port Pin Specifications Standard RS232 TMAC-6125 Specifications Port SpecificationsTAUD-6100 Specifications TDEC-6100 SpecificationsTDEC-6161 Specifications LNB Port Specifications TDEM-6110 Specifications01-0870-401B 01/03 PAL Tiernan VBI Data TransmissionTiernan VBI Data Transmission Tiernan Proprietary Closed Captions Tiernan CC Tiernan CC Mode is for Ntsc Format OnlyDVB 422 Expanded Windows, 16-line and 32-line Lines Expanded Windows Field for an Encoded Picture Frame Tiernan Closed Captions Front Panel Commands Front Panel Commands for Encoder ConfigurationVE TCC Remote Commands for Encoder ConfigurationVE Vbipass 32LINES01-0870-401B 01/03 Typical Option Module Option Module OverviewOption Module Overview Demodulator Tuner SAW Filter Demodulator Application NotesIndustry Standard LNB Frequencies Spacing Information RateEb/N0 Definition Output Spectrum WidthMinimum and Maximum Information Rates TransponderDemodulator Low Eb/N0 Alarm Estimating Eb/N0 Using a Spectrum AnalyzerEb/N0 Estimation Algorithm Spectrum AnalyzerDiagnostic Commands Offset = Actual RF Programmed RF Table Top and Rack Mount Installation Instructions Rear Rack Mount Instructions Fuse Rear Rack Bracket Mounting Instructions01-0870-401B 01/03 Index Index