JVC VR 601 instruction manual Playback function bar

Page 67

Function Buttons

Description

 

Playback function bar.

 

Play- Click to play back a recorded video from the PLAY LIST.

 

Pause- Click to freeze the image.

 

Stop- Click to stop playing back the recorded video or cease

 

recording.

 

REC- Click to activate the recording function of the device.

 

Step- Click to view images picture-by-picture.

 

 

 

Click to return to the Multi-Device mode.

 

 

Click to save a viewing image in the local computer.

Click to enter the SETUP page, which allows you to program the recording rate, recording quality, and schedule recording.

Click to exit the Network Viewer program.

Multiplexer format list box.

Select a MUX from the drop-down list which is connected with the DVR, so the Network Viewer will be able to display cameras in corresponding to the camera input of the Multiplexer. If your MUX isn’t available, please select the Other Multiplexer option for use. The Viewer will display cameras in the thumbnail format. (Sequentially displaying images will appear one after another in the adjacent display window)

Recorded video list box. This box allows you to access all recorded video, which are stored in the HDD of the connected devices. To review a recorded video, just click an entry from the list and click

the button.

PgUp/PgDn: To scroll up and down the list.

VR-601 Status Box. This box indicates the selected device status.

PLAY: The device is in the playback mode.

LIVE: The device is in the live display mode.

WAIT: The device is processing the command.

PAUSE: Pauses the image.

This allows you to search a recorded video kept in the HDD of the device. Enter the MONTH/DAY/YEAR HOUR: MINUTE you wish to

search and click GO to proceed.

Split-Screen display function bar. This allows you to display the selected device in multi-format screens of 1, 2x2, 3x3, and 4x4.

Image display area. Displays the images of each camera and the title and time/date information on the top blue bar. Double click the image to view a full screen of the camera.

67

Image 67
Contents Digital Video Recorder Important Safeguards Avertissement Safety Precautions for USA and CanadaConnection to the mains supply Power SystemFor Your Safety Australia Important In the United Kingdom Mains Supply AC 230Place of storage and use About the provided power cables for VR-601 UHandling the unit AC adapter section Important Safety InstructionsTable Of Contents Specifications Compatible Multiplexers Product Introduction Product FeaturesOperate button Front ViewHard-disk drive compartment Hard-disk compartment lockUp / Down buttons Rec IndicatorDisk Indicator Operate IndicatorMobile Rack HDD LED Mobile Rack Power LEDRear View This Figure is Looked from the Rear Alarm In/OutNo Connection Connectiong to the AC Adapter Basic ConnectionMemo Connecting with a Multiplexer Connecting with a Single CameraMultiplexer Connecting with a QuadClock SET Attaching AN External Device to DVRMaxtor Hard-Disk Drive InstallationQuality Best Ntsc Rate 6 HR System InformationMUX OFF Size POS Updating System Software Standard Configuring Recording SettingsBest HighNtsc MUX OFF PAL MUX OFF Recording Operations Timer RecordingManual Recording Start END 0000-0000 0000-0000 0000-0000 0000-0000 0000-0000 0000-0000 0000-0000 M 0000-0000 WREC Quality Best Audio OFF ALM Type ALM Duration Alarm RecordingPRE- Alarm OFF Main Alarm REC Enable Externally triggered RecordingDiagrams below Search to play back a particular recorded video Operation Status From REC mode to Playback modePlayback Operations Fast Forward/ReverseSlow Forward/Reverse You can also operate by using button and buttonPlay Back Picture-by-picture Full List Search Search Full List Alarm List Time Search Thumbnail SD CardSearch Operations Play Back Recorded Video from a HDD of the mobile rackSearch Alarm list SearchAlarm List Time SearchSearch Thumbnail Year Full List Thumbnail Search2003 SD Card Search Alarm Select Main Backup ALL to HD2 Backup OperationsMobile Rack HD Backup Backup Backup Main SET HD2 Usage1220 2001-02-01 0330 2001-03-02 0420 1330 Alarm Select Main Backup Alarm to HD2Disk Setting Reformat HD2 Usage Search buttonArchive Single image Clips into SD Card Security Digital Card SD Card BackupBackup the System setting info into SD Card Save the whole setting into the SD cardKey Lock Operation Transfer the system setting info of DVR to anotherMenu Setup REC Quality REC SettingAlarm Setting REC Quality PRE- Alarm REC Schedule Clock / TimerClock / Timer SET REC Enable OFF Main Timer REC Enable TimerNET Enable NET Enable OFF NET Dhcp NET IP SET FTP Setting MainCommunication REC Mode Comm Setting FTP Setting Comm IDEnable REC Mode Alarm RECPath PasswordFTP Account FTP IP UserBackup Disk SettingBackup Full Main Disk REFORMAT/CLEAR Backup HD HD2 UsageSystem Situation MAC 00 0c 0c 00 00 Bios SW 1.00J Date Jun 9 General Command Format SetupCommunication Protocol Value of a specific front panel key Description of System State Request Time Second Category=0x02Set Time Second Category=0x02 Request State Second Category=0x06Jumper settings of hard-disk drives for the system Location Mobile Rack InstallationPage Push the active-handle inward Lock the Key System Default SET RS232 / RS485 Disk Setting ReformatD Message Meanings PIN no Network ViewerPage View the VR-601 video from a remote PC Function Buttons Description Viewing images View all the connected devicesView single device Playback function bar Set the record timer Change the Record & Timer Properties Via the NetworkSet the regular record settings Set the Alarm record settingsArchive Images to the Computer Image Viewer Point stops recording Previously recorded data remaining 12-02-02 01-30-03 Lists 2999 02-03-03 3000 02-08-03Connect to a LAN Hub Intranet Physical specification of RJ-45 cable for EthernetCable Connections Connect to a computerConnect to WAN Internet RJ-45 PIN configuration for LAN HubConfigure Your DVR Network Settings Enable DVR Network FunctionSet IP Address Enable Dhcp Function12.3 TCP/IP Communication Software Page 12.5 TCP/IP Configuration setting 12.4 TCP/IP installationClick Start Settings Control Panel Network Click Start Programs MS-DOS Prompt Connection TestingPage Model Number VR-601 U VR-601 E Design and specifications subject to change without noticeDVR Viewer Manufacturer Model ChannelColors Decode on