Sterling BF3-600 specifications Step

Page 16

Enter the additive percentage by using the Arrow Keys . (The range of values that can be entered is 0.01% to 50.00%. The arrow keys are used to change all process variables. The double arrow key allows the user to ramp up or down by larger increments.)

Step 2:

Press Input again.

The symbols “g,” or “lb”, “min” and the screw symbol flash.

After the “2”quickly flashes on the display, a number in the format xx.xxx will come up on the display.

Enter the shot weight using the arrow keys. The range of values that can be entered is 001.0 to 6500 grams (0.01 to 14.30 pounds).

Step 3:

Press Input a third time.

The screw and “s” symbols flash.

After “3” flashes quickly on the display, a number in the format xxx.xx will come up on the display.

Enter the screw recovery time in seconds. This time represents the amount of time the molding machine screw is in recovery. This value is an estimate. The Digital Dosing unit measures the actual recovery time and automatically updates

Digital Dosing Units

15

Image 16
Contents SDD Digital Dosing Units Parts and Service Department Table of Contents Introduction Station Digital Dosing UnitI C K A R T G E S V E U E R D E R Controller Touch KeypadKeys and Symbols Symbols Recipe Setup For Injection Molding Quick Start-upUnpacking MountingRecipe Setup For Extrusion CalibrationI C K A R T G E S V E U E R D E R Initial Installation And Operation Initial InstallationElectrical diagram of connections Electrical DiagramDiagram of frequency inputs Initial OperationRecipe Input Injection Molding Injection MoldingStep Step Step Step Operation-Injection Molding Extrusion Constant Recipe Input Extrusion ConstantStep Step Operation -Extrusion Constant Extrusion Proportional Recipe Input Extrusion ProportionalStep Operation -Extrusion Proportional Calibration Determining the Calibration Weight Repeat steps 3 and 4 four 4 more times Digital Dosing Units Recipe Storage And Recall Advanced Operations/ Control FunctionsRecipe Storage Recipe Recall Clearing The Totalizer Acknowledging AlarmsOptional Equipment Alarms Level ProbesMixer Euromap E17 InterfaceMaintenance Maintenance IntervalsRemoving the Scraper Removing the scraperInstalling the scraper Cleaning the Digital Dosing Dosing StationDismantling the Dosing Station Installing the Dosing Station Installing the Dosing Disc Removing the Dosing DiscInstalling Different Types of Dosing Discs Removing/Replacing the Scraper in the DT Dosing StationCleaning the DT Dosing Station Exchangeable Stations Replacing FusesSee Appendix D on page 61 for fuse part numbers General Troubleshooting Unit Will Not Operate Appendix a TroubleshootingMalfunctions or Errors Error Codes Error Codes Determining the Software Setup Factor Recipe FormulasInjection Molding ExtrusionRecipe Limitations Extrusion Extrusion Mode Appendix B Basic Parameter SettingsMax. input frequency = Hz Determining the Configuration Value Extrusion Constant or ProportionalProbe Digital Dosing Units Basic Parameter Settings Digital Dosing Units Digital Dosing Units Disc Dosing Factor Disc Guide D30-051725 DT30-102025 DP30 Specification Sheet Disc Dosing Factor TableDigital Dosing unit parameter setup Page Station 1 Digital Dosing Unit Station 2 Digital Dosing Unit Side View TOP ViewDosing Unit Electrical Schematic Chart Appendix D Spare Parts List Dosing Disc/Shear Order NumbersPage Service Department Technical AssistanceParts Department Sales Department