Sterling BF3-600 specifications Digital Dosing unit parameter setup

Page 60

Digital Dosing unit parameter setup 7-14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bison - Black motor

 

Bauer - Blue motor

Comments

 

Parameter

 

 

 

 

 

 

 

 

 

 

 

RPM

2

6

12

38

6.4

11.5

35.5

 

 

 

7

 

65000

25200

14103

4387

11739

6600

2135

These values refer to the pulses of the encoder

8

 

 

 

 

 

 

 

 

 

 

 

 

0.5

 

 

 

0.7

 

Nominal motor current

9

 

Ext

 

Inj

 

Ext

 

Inj

 

 

 

 

 

1040

 

16

 

1040

 

16

(see separate calculation sheet for parameter #9)

 

10

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

1

 

Factory set, do not change

 

 

 

 

 

 

 

 

 

 

 

 

11

 

Ext

 

Inj

 

Ext

 

Inj

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

 

50

 

50

 

50

Ext = minimum input frequency w/follower only

12

 

Ext

 

Inj

 

Ext

 

Inj

Inj = Minimum # of machine cycles per dosing

 

 

 

 

 

 

 

 

 

10

 

5.56

 

10

 

5.56

Ext = Span factor (sf) calculated using: sf=1000/rpm@10vdc

13

 

Ext

 

Inj

 

Ext

 

Inj

sf = 1000/rpm @20ma

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

0

 

0

Communication address used with Euromap 17 (use 1instead of 0)

14

 

Ext

 

Inj

 

Ext

 

Inj

 

 

 

 

 

0

 

0

 

0

 

0

For use with Mico mix hopper (use 1 instead of 0)

59

Image 60
Contents SDD Digital Dosing Units Parts and Service Department Table of Contents Introduction Station Digital Dosing UnitI C K A R T G E S V E U E R D E R Controller Touch KeypadKeys and Symbols Symbols Recipe Setup For Injection Molding Quick Start-upUnpacking MountingRecipe Setup For Extrusion CalibrationI C K A R T G E S V E U E R D E R Initial Installation And Operation Initial InstallationElectrical diagram of connections Electrical DiagramDiagram of frequency inputs Initial OperationInjection Molding Recipe Input Injection MoldingStep Step Step Step Operation-Injection Molding Extrusion Constant Recipe Input Extrusion ConstantStep Step Operation -Extrusion Constant Extrusion Proportional Recipe Input Extrusion ProportionalStep Operation -Extrusion Proportional Calibration Determining the Calibration Weight Repeat steps 3 and 4 four 4 more times Digital Dosing Units Advanced Operations/ Control Functions Recipe Storage And RecallRecipe Storage Recipe Recall Acknowledging Alarms Clearing The TotalizerOptional Equipment Alarms Level ProbesMixer Euromap E17 InterfaceMaintenance Maintenance IntervalsRemoving the Scraper Removing the scraperCleaning the Digital Dosing Dosing Station Installing the scraperDismantling the Dosing Station Installing the Dosing Station Installing the Dosing Disc Removing the Dosing DiscInstalling Different Types of Dosing Discs Removing/Replacing the Scraper in the DT Dosing StationCleaning the DT Dosing Station Exchangeable Stations Replacing FusesSee Appendix D on page 61 for fuse part numbers Appendix a Troubleshooting General Troubleshooting Unit Will Not OperateMalfunctions or Errors Error Codes Error Codes Determining the Software Setup Factor Recipe FormulasInjection Molding ExtrusionRecipe Limitations Extrusion Appendix B Basic Parameter Settings Extrusion ModeMax. input frequency = Hz Determining the Configuration Value Extrusion Constant or ProportionalProbe Digital Dosing Units Basic Parameter Settings Digital Dosing Units Digital Dosing Units Disc Dosing Factor Disc Guide D30-051725 DT30-102025 DP30 Specification Sheet Disc Dosing Factor TableDigital Dosing unit parameter setup Page Station 1 Digital Dosing Unit Station 2 Digital Dosing Unit Side View TOP ViewDosing Unit Electrical Schematic Chart Appendix D Spare Parts List Dosing Disc/Shear Order NumbersPage Service Department Technical AssistanceParts Department Sales Department