Sterling BF3-600 specifications Determining the Calibration Weight

Page 28

Determining the Calibration Weight

Step 1:

To start the calibration process, press the calibration key.

Step 2:

Once the sample container is in position, press .

The disc will rotate 1/4 revolution and dispense material into the sample container. After the disc stops, the screen will remain blank.

This sample should be returned to the material hopper without weighing. This sample is used only to ensure that all disc pockets are completely filled.

Replace container in calibration box (or under material outlet tube)

Step 3:

Press to take a sample for weighing.

Digital Dosing Units

27

Image 28
Contents SDD Digital Dosing Units Parts and Service Department Table of Contents Introduction Station Digital Dosing UnitI C K A R T G E S V E U E R D E R Controller Touch KeypadKeys and Symbols Symbols Recipe Setup For Injection Molding Quick Start-upUnpacking MountingRecipe Setup For Extrusion CalibrationI C K A R T G E S V E U E R D E R Initial Installation And Operation Initial InstallationElectrical diagram of connections Electrical DiagramDiagram of frequency inputs Initial OperationRecipe Input Injection Molding Injection MoldingStep Step Step Step Operation-Injection Molding Extrusion Constant Recipe Input Extrusion ConstantStep Step Operation -Extrusion Constant Extrusion Proportional Recipe Input Extrusion ProportionalStep Operation -Extrusion Proportional Calibration Determining the Calibration Weight Repeat steps 3 and 4 four 4 more times Digital Dosing Units Recipe Storage And Recall Advanced Operations/ Control FunctionsRecipe Storage Recipe Recall Clearing The Totalizer Acknowledging AlarmsOptional Equipment Alarms Level ProbesMixer Euromap E17 InterfaceMaintenance Maintenance IntervalsRemoving the Scraper Removing the scraperInstalling the scraper Cleaning the Digital Dosing Dosing StationDismantling the Dosing Station Installing the Dosing Station Installing the Dosing Disc Removing the Dosing DiscInstalling Different Types of Dosing Discs Removing/Replacing the Scraper in the DT Dosing StationCleaning the DT Dosing Station Exchangeable Stations Replacing FusesSee Appendix D on page 61 for fuse part numbers General Troubleshooting Unit Will Not Operate Appendix a TroubleshootingMalfunctions or Errors Error Codes Error Codes Determining the Software Setup Factor Recipe FormulasInjection Molding ExtrusionRecipe Limitations Extrusion Extrusion Mode Appendix B Basic Parameter SettingsMax. input frequency = Hz Determining the Configuration Value Extrusion Constant or ProportionalProbe Digital Dosing Units Basic Parameter Settings Digital Dosing Units Digital Dosing Units Disc Dosing Factor Disc Guide D30-051725 DT30-102025 DP30 Specification Sheet Disc Dosing Factor TableDigital Dosing unit parameter setup Page Station 1 Digital Dosing Unit Station 2 Digital Dosing Unit Side View TOP ViewDosing Unit Electrical Schematic Chart Appendix D Spare Parts List Dosing Disc/Shear Order NumbersPage Service Department Technical AssistanceParts Department Sales Department