Sterling BF3-600 specifications Step

Page 25

Step 2:

or

Press again.

The machine displays a flashing “g” or “lb”, a flashing “min” and .

After “2” flashes quickly on the display, a number in the format xxx.xx will come up on the display.

Enter the expected extruder throughput during production in grams per minute or pounds per minute. The range of values that can be entered is 001.0 to 6500 grams per minute (00.01 to 14.30 lb/m).

Step 3:

Press a third time.

• The machine displays a flashing screw

.

After “3” flashes quickly on the display, a number in the format xxx.xx will come up on the display.

Enter the extruder screw speed (rpm) corresponding to the throughput entered in step 2.

Digital Dosing Units

24

Image 25
Contents SDD Digital Dosing Units Parts and Service Department Table of Contents Station Digital Dosing Unit IntroductionI C K A R T G E S V E U E R D E R Touch Keypad ControllerKeys and Symbols Symbols Quick Start-up Recipe Setup For Injection MoldingUnpacking MountingCalibration Recipe Setup For ExtrusionI C K A R T G E S V E U E R D E R Initial Installation Initial Installation And OperationElectrical Diagram Electrical diagram of connectionsInitial Operation Diagram of frequency inputsRecipe Input Injection Molding Injection MoldingStep Step Step Step Operation-Injection Molding Recipe Input Extrusion Constant Extrusion ConstantStep Step Operation -Extrusion Constant Recipe Input Extrusion Proportional Extrusion ProportionalStep Operation -Extrusion Proportional Calibration Determining the Calibration Weight Repeat steps 3 and 4 four 4 more times Digital Dosing Units Recipe Storage And Recall Advanced Operations/ Control FunctionsRecipe Storage Recipe Recall Clearing The Totalizer Acknowledging AlarmsOptional Equipment Level Probes AlarmsEuromap E17 Interface MixerMaintenance Intervals MaintenanceRemoving the Scraper Removing the scraperInstalling the scraper Cleaning the Digital Dosing Dosing StationDismantling the Dosing Station Installing the Dosing Station Removing the Dosing Disc Installing the Dosing DiscRemoving/Replacing the Scraper in the DT Dosing Station Installing Different Types of Dosing DiscsCleaning the DT Dosing Station Replacing Fuses Exchangeable StationsSee Appendix D on page 61 for fuse part numbers General Troubleshooting Unit Will Not Operate Appendix a TroubleshootingMalfunctions or Errors Error Codes Error Codes Recipe Formulas Determining the Software Setup FactorInjection Molding ExtrusionRecipe Limitations Extrusion Extrusion Mode Appendix B Basic Parameter SettingsMax. input frequency = Hz Extrusion Constant or Proportional Determining the Configuration ValueProbe Digital Dosing Units Basic Parameter Settings Digital Dosing Units Digital Dosing Units Disc Dosing Factor Disc Guide D30-051725 DT30-102025 DP30 Disc Dosing Factor Table Specification SheetDigital Dosing unit parameter setup Page Station 1 Digital Dosing Unit Side View TOP View Station 2 Digital Dosing UnitDosing Unit Electrical Schematic Chart Dosing Disc/Shear Order Numbers Appendix D Spare Parts ListPage Technical Assistance Service DepartmentParts Department Sales Department