Sterling BF3-600 specifications Operation -Extrusion Proportional

Page 26

Step 4:

or

1.Press a fourth time.

2.The machine displays a flashing and “g”.

3.After “4” flashes quickly on the screen, a number in the format xxx.xx will come up on the display.

Enter the calibration weight in grams or pounds. If the calibration weight is unknown, enter “00.00” and complete the calibration procedure (section 3.6) to obtain the correct value. Upon completion of the calibration procedure, the calibration weight will automatically be updated into the recipe. The range of values that can be entered in this field is 00.00 to 400.0.

Step 5:

Press a fifth time to return to the totalizer.

Operation –Extrusion Proportional

;Ensure that the unit is properly installed (Section 3.1)

;A recipe is entered (“Recipe Input-Extrusion Proportional” Section )

;The feeder is calibrated (Section 3.6), before attempting to begin operations.

1.If desired, clear the totalizer by pressing continuously for 5 seconds until the display is reset to “00.00.”

Digital Dosing Units

25

Image 26
Contents SDD Digital Dosing Units Parts and Service Department Table of Contents Introduction Station Digital Dosing UnitI C K A R T G E S V E U E R D E R Controller Touch KeypadKeys and Symbols Symbols Unpacking Recipe Setup For Injection MoldingQuick Start-up MountingRecipe Setup For Extrusion CalibrationI C K A R T G E S V E U E R D E R Initial Installation And Operation Initial InstallationElectrical diagram of connections Electrical DiagramDiagram of frequency inputs Initial OperationStep Injection MoldingRecipe Input Injection Molding Step Step Step Operation-Injection Molding Extrusion Constant Recipe Input Extrusion ConstantStep Step Operation -Extrusion Constant Extrusion Proportional Recipe Input Extrusion ProportionalStep Operation -Extrusion Proportional Calibration Determining the Calibration Weight Repeat steps 3 and 4 four 4 more times Digital Dosing Units Recipe Storage Advanced Operations/ Control FunctionsRecipe Storage And Recall Recipe Recall Optional Equipment Acknowledging AlarmsClearing The Totalizer Alarms Level ProbesMixer Euromap E17 InterfaceRemoving the Scraper MaintenanceMaintenance Intervals Removing the scraperDismantling the Dosing Station Cleaning the Digital Dosing Dosing StationInstalling the scraper Installing the Dosing Station Installing the Dosing Disc Removing the Dosing DiscInstalling Different Types of Dosing Discs Removing/Replacing the Scraper in the DT Dosing StationCleaning the DT Dosing Station Exchangeable Stations Replacing FusesSee Appendix D on page 61 for fuse part numbers Malfunctions or Errors Error Codes Appendix a TroubleshootingGeneral Troubleshooting Unit Will Not Operate Error Codes Injection Molding Determining the Software Setup FactorRecipe Formulas ExtrusionRecipe Limitations Extrusion Max. input frequency = Hz Appendix B Basic Parameter SettingsExtrusion Mode Determining the Configuration Value Extrusion Constant or ProportionalProbe Digital Dosing Units Basic Parameter Settings Digital Dosing Units Digital Dosing Units Disc Dosing Factor Disc Guide D30-051725 DT30-102025 DP30 Specification Sheet Disc Dosing Factor TableDigital Dosing unit parameter setup Page Station 1 Digital Dosing Unit Station 2 Digital Dosing Unit Side View TOP ViewDosing Unit Electrical Schematic Chart Appendix D Spare Parts List Dosing Disc/Shear Order NumbersPage Parts Department Service DepartmentTechnical Assistance Sales Department