Installing Different Types of Dosing Discs
Dosing discs of the same type may be exchanged for each other without any problems. If dosing discs with a different compartment number are installed, this has to be entered in the control system!
1.Enter the (preliminary) calibration value of the freshly installed dosing disc (* = bulk density 550g/l, ** = bulk density 700g/l).
2.Execute “calibration” to determine the final calibration value.
5.5Removing/Replacing the Scraper in the DT Dosing Station
1.Empty the dosing station.
2.Open the profile clamp (C) of the
dosing container.
3.Remove the profile clamp (C)
4.Remove the dosing container (B) along with the dosing hopper (A).
5.Loosen the 3 plastic screws on the stripper
6.Remove the scraper and holding plate.
7.Install the new scraper along with the holding plate.
8.Tighten down the 3 plastic screws. Make sure that the stripper is fitted parallel to the dosing plate (Use only plastic screws
Digital Dosing Units | 39 |