Sterling BF3-600 specifications Step

Page 17

this value during operation. The range of values that can be entered in this field is 00.50 to 99.99 seconds.

Step 4:

or

Press Input a fourth time.

The symbols “g” or “lb”and flash.

After “4” quickly flashes on the screen, a number in the format xxxx.x will come up on the display.

Enter the material calibration weight using the arrow keys.

If the calibration weight is unknown, reference Section 5 of this manual. Complete the calibration procedure (section 3.6) to obtain the correct value. Upon completion of the calibration procedure, the calibration weight will automatically be updated into the recipe. The range of values that can be entered in this field is 00.0 to 400.0.

Step 5:

Press again and the symbol “s” will light up and the number “5” will be displayed if you have a blending unit and have invoked this option.

Digital Dosing Units

16

Image 17
Contents SDD Digital Dosing Units Parts and Service Department Table of Contents Station Digital Dosing Unit IntroductionI C K A R T G E S V E U E R D E R Touch Keypad ControllerKeys and Symbols Symbols Quick Start-up Recipe Setup For Injection MoldingUnpacking MountingCalibration Recipe Setup For ExtrusionI C K A R T G E S V E U E R D E R Initial Installation Initial Installation And OperationElectrical Diagram Electrical diagram of connectionsInitial Operation Diagram of frequency inputsStep Injection MoldingRecipe Input Injection Molding Step Step Step Operation-Injection Molding Recipe Input Extrusion Constant Extrusion ConstantStep Step Operation -Extrusion Constant Recipe Input Extrusion Proportional Extrusion ProportionalStep Operation -Extrusion Proportional Calibration Determining the Calibration Weight Repeat steps 3 and 4 four 4 more times Digital Dosing Units Recipe Storage Advanced Operations/ Control FunctionsRecipe Storage And Recall Recipe Recall Optional Equipment Acknowledging AlarmsClearing The Totalizer Level Probes AlarmsEuromap E17 Interface MixerMaintenance Intervals MaintenanceRemoving the Scraper Removing the scraperDismantling the Dosing Station Cleaning the Digital Dosing Dosing StationInstalling the scraper Installing the Dosing Station Removing the Dosing Disc Installing the Dosing DiscRemoving/Replacing the Scraper in the DT Dosing Station Installing Different Types of Dosing DiscsCleaning the DT Dosing Station Replacing Fuses Exchangeable StationsSee Appendix D on page 61 for fuse part numbers Malfunctions or Errors Error Codes Appendix a TroubleshootingGeneral Troubleshooting Unit Will Not Operate Error Codes Recipe Formulas Determining the Software Setup FactorInjection Molding ExtrusionRecipe Limitations Extrusion Max. input frequency = Hz Appendix B Basic Parameter SettingsExtrusion Mode Extrusion Constant or Proportional Determining the Configuration ValueProbe Digital Dosing Units Basic Parameter Settings Digital Dosing Units Digital Dosing Units Disc Dosing Factor Disc Guide D30-051725 DT30-102025 DP30 Disc Dosing Factor Table Specification SheetDigital Dosing unit parameter setup Page Station 1 Digital Dosing Unit Side View TOP View Station 2 Digital Dosing UnitDosing Unit Electrical Schematic Chart Dosing Disc/Shear Order Numbers Appendix D Spare Parts ListPage Technical Assistance Service DepartmentParts Department Sales Department