Schneider Electric LXM32M manual Setting the gateway

Page 44

5 Commissioning

LXM32M

 

 

5.5Setting the gateway

The IP address of the gateway is set by means of the parameters

EthIPgate1 ... EthIPgate4.

Set the IP address of the gateway with the parameters

EthIPgate1 ... EthIPgate4.

Parameter name

Description

Unit

Data type

Parameter address

HMI menu

 

Minimum value

R/W

via fieldbus

HMI name

 

Factory setting

Persistent

 

 

 

Maximum value

Expert

 

 

 

 

 

 

EthIPgate1

IP address gateway, byte 1

-

UINT16

CANopen 3044:Fh

ConF CoM-

Changed settings become active the next

0

UINT16

Modbus 17438

0

UINT16

Profibus 17438

iPG1

time the product is switched on.

255

UINT16

CIP 168.1.15

 

 

 

 

R/W

 

 

 

 

per.

 

 

 

 

-

 

 

 

 

 

 

EthIPgate2

IP address gateway, byte 2

-

UINT16

CANopen 3044:10h

ConF CoM-

Changed settings become active the next

0

UINT16

Modbus 17440

0

UINT16

Profibus 17440

iPG2

time the product is switched on.

255

UINT16

CIP 168.1.16

 

 

 

 

R/W

 

 

 

 

per.

 

 

 

 

-

 

 

 

 

 

 

EthIPgate3

IP address gateway, byte 3

-

UINT16

CANopen 3044:11h

ConF CoM-

Changed settings become active the next

0

UINT16

Modbus 17442

0

UINT16

Profibus 17442

iPG3

time the product is switched on.

255

UINT16

CIP 168.1.17

 

 

 

 

R/W

 

 

 

 

per.

 

 

 

 

-

 

 

 

 

 

 

EthIPgate4

IP address gateway, byte 4

-

UINT16

CANopen 3044:12h

ConF CoM-

Changed settings become active the next

0

UINT16

Modbus 17444

0

UINT16

Profibus 17444

iPG4

time the product is switched on.

255

UINT16

CIP 168.1.18

 

 

 

 

R/W

 

 

 

 

per.

 

 

 

 

-

 

 

 

 

 

 

0198441113843, V1.01, 01.2012

44

Modbus-TCP module

Image 44
Contents LXM32M Important information Table of contents Diagnostics and troubleshooting Accessories and spare parts LXM32M About this manual Further reading Introduction Fieldbus products on the networkLXM32M Intended use Before you begin safety informationQualification of personnel Hazard categories Basic information Standards and terminology Basics Modbus TCP technologyFunction principle Bus topologyNetwork service Snmp Client / server modelModbus TCP protocol Structure of a Modbus messageMbap header Field Length DescriptionModbus TCP communication Connection managementModbus response to a Modbus request Excep Name Description Tion CodeReading and writing parameters Address Value4 I/O scanning to Drive Profile Lexium 4.1 I/O scanning Output Byte Meaning Data type Parameter address4.2 I/O scanning Input Bit MeaningBit Signal Factory setting InputsParameter channel Ctrl Subindex Index Field Bytes Value Meaning Modbus services Function CodeFunction Code 3 Read Multiple Registers Function Code 8 Diagnostics Sub-function Code Diagnostics functionFunction Code 16 Write Multiple Registers Function Code 23 ReadWrite Multiple Registers Function Code 43 Encapsulated Interface Transport Object ID Object name ValueExamples Example of Function CodeLXM32M Description Order no InstallationInstallation of the module Electrical installation Pin Signal MeaningCommissioning Commissioning the deviceFirst Setup Switching on the device Power stage supply is switched offBootp / boot Bootp Manual assignment of the network addressManual / MAnu Manual Dhcp / dhcP DhcpIP address Ethernet module, byte Assignment of the network address via Bootp Assignment of the network address via Dhcp Setting the transmission rate Setting the protocolSetting the gateway Set the IP address of the gateway with the parametersMaster with Word Swap Activating I/O scanning Setting I/O-ScanningSetting the master for I/O scanning Setting the mapping for I/O scanning PLC Setting the web server Setting communication monitoring for I/O scanning0198441113843, V1.01 Operation Bit Name Meaning Operating statesIndication of the operating state Changing the operating state Bit Name Meaning Operating stateBit Name Description Indicating and monitoring the operating modeOperating modes Starting and changing an operating mode Bit Name DescriptionOverview of operating modes MODE+ACTIONOperating mode Jog Operating mode Electronic Gear Operating mode Profile Torque 24 hOperating mode Profile Velocity 23 hOperating mode Profile Position Operating mode Homing Operating mode Motion Sequence LXM32M6 OperationExtended settings Web serverMain menu Submenu Content User interfaceAccessing the FTP server FTP serverFDR service Fast Device Replacement LXM32M Diagnostics and troubleshooting Fieldbus communication error diagnosticsStatus LEDs Color Status MeaningColor Meaning for EtherNet/IP Meaning for Modbus TCPError indication Excep Name Description Tion Code LXM32M Accessories and spare parts CablesLXM32M Glossary Units and conversion tablesTemperature RotationTorque Moment of inertiaTerms and Abbreviations LXM32M Index LXM32M