LXM32M | 7 Diagnostics and troubleshooting | ||
|
|
|
|
|
|
|
|
| Excep- | Name | Description |
| tion Code |
|
|
|
|
|
|
| 01 | Illegal Function Code | The "Function Code" is unknown to the |
|
|
| server. |
|
|
|
|
| 02 | Illegal Data Address | Depends on the Modbus request |
|
|
|
|
| 03 | Illegal Data Value | Depends on the Modbus request |
|
|
|
|
| 04 | Server Failure | The server was unable to properly termi- |
|
|
| nate processing. |
|
|
|
|
| 05 | Acknowledge | The server has accepted the Modbus |
|
|
| request. However, the execution takes a |
|
|
| relatively long time. The server therefore |
|
|
| only returns an acknowledgement con- |
|
|
| firming receipt of the service request. |
|
|
|
|
| 06 | Server Busy | The server was unable to accept the |
|
|
| Modbus request. It is the responsibility of |
|
|
| the application on the client to determine |
|
|
| whether and when to |
|
|
|
|
| 0A | Gateway Problem | The gateway path is unavailable. |
|
|
|
|
| 0B | Gateway Problem | The targeted device does not respond. |
|
|
| The gateway generates this error. |
|
|
|
|
0198441113843, V1.01, 01.2012
73 |