Schneider Electric LXM32M manual Operating mode Jog, Bit Name Meaning

Page 57

LXM32M

6 Operation

 

 

6.2.4Operating mode Jog

Starting the operating mode The operating mode is set and started in the process data channel with the transmit data (master to slave).

dmControl

Reference value RefA32

Reference value RefB32

Bits 0 ... 6

 

 

MODE+ACTION

 

 

 

 

 

1Fh

Value 0: No movement

-

 

Value 1: Slow movement

 

 

in positive direction

 

 

Value 2: Slow movement

 

 

in negative direction

 

 

Value 5: Fast movement in

 

 

positive direction

 

 

Value 6: Fast movement in

 

 

negative direction

 

 

 

 

Status information The word "driveStat" provides information on the operating mode.

Bit

Name

Meaning

 

 

 

13

X_ADD1

Reserved

 

 

 

14

X_END

0: Operating mode started

 

 

1: Operating mode terminated

 

 

 

15

X_ERR

0: No error

 

 

1: Error

 

 

 

Terminating the operating mode The operating mode is terminated when the motor is at a standstill and one of the following conditions is met:

Value 0 RefA

Stop caused by "Halt" or "Quick Stop"

Stop caused by an error

0198441113843, V1.01, 01.2012

Modbus-TCP module

57

Image 57
Contents LXM32M Important information Table of contents Diagnostics and troubleshooting Accessories and spare parts LXM32M About this manual Further reading Fieldbus products on the network IntroductionLXM32M Before you begin safety information Qualification of personnelIntended use Hazard categories Basic information Standards and terminology Modbus TCP technology BasicsFunction principle Bus topologyClient / server model Network service SnmpStructure of a Modbus message Modbus TCP protocolField Length Description Mbap headerConnection management Modbus TCP communicationExcep Name Description Tion Code Modbus response to a Modbus requestAddress Value Reading and writing parameters4 I/O scanning to Drive Profile Lexium Byte Meaning Data type Parameter address 4.1 I/O scanning OutputBit Meaning 4.2 I/O scanning InputInputs Bit Signal Factory settingParameter channel Ctrl Subindex Index Modbus services Function Code Function Code 3 Read Multiple RegistersField Bytes Value Meaning Sub-function Code Diagnostics function Function Code 8 DiagnosticsFunction Code 16 Write Multiple Registers Function Code 23 ReadWrite Multiple Registers Object ID Object name Value Function Code 43 Encapsulated Interface TransportExample of Function Code ExamplesLXM32M Installation Installation of the moduleDescription Order no Pin Signal Meaning Electrical installationCommissioning the device CommissioningSwitching on the device Power stage supply is switched off First SetupManual assignment of the network address Bootp / boot BootpManual / MAnu Manual Dhcp / dhcP DhcpIP address Ethernet module, byte Assignment of the network address via Bootp Assignment of the network address via Dhcp Setting the protocol Setting the transmission rateSet the IP address of the gateway with the parameters Setting the gatewayMaster with Word Swap Setting I/O-Scanning Setting the master for I/O scanningActivating I/O scanning Setting the mapping for I/O scanning PLC Setting communication monitoring for I/O scanning Setting the web server0198441113843, V1.01 Operation Operating states Indication of the operating stateBit Name Meaning Bit Name Meaning Operating state Changing the operating stateIndicating and monitoring the operating mode Operating modesBit Name Description Bit Name Description Starting and changing an operating modeMODE+ACTION Overview of operating modesOperating mode Jog Operating mode Electronic Gear 24 h Operating mode Profile Torque23 h Operating mode Profile VelocityOperating mode Profile Position Operating mode Homing LXM32M6 Operation Operating mode Motion SequenceWeb server Extended settingsUser interface Main menu Submenu ContentFTP server Accessing the FTP serverFDR service Fast Device Replacement LXM32M Fieldbus communication error diagnostics Diagnostics and troubleshootingColor Status Meaning Status LEDsMeaning for EtherNet/IP Meaning for Modbus TCP ColorError indication Excep Name Description Tion Code LXM32M Cables Accessories and spare partsLXM32M Units and conversion tables GlossaryRotation TemperatureTorque Moment of inertiaTerms and Abbreviations LXM32M Index LXM32M