LXM32M | 5 Commissioning |
|
|
5.7.4Setting communication monitoring for I/O scanning
WARNING
LOSS OF CONTROL
The product is unable to detect an interruption of the network link if connection monitoring is not active.
•Verify that connection monitoring is on.
•The shorter the time for monitoring, the faster the detection of the interruption.
Failure to follow these instructions can result in death, serious injury or equipment damage.
Communication monitoring for I/O scanning is set by means of the parameter EthMbScanTimeout.
▶Set communication monitoring for I/O scanning with the parameter
EthMbScanTimeout.
Parameter name | Description | Unit | Data type | Parameter address |
HMI menu |
| Minimum value | R/W | via fieldbus |
HMI name |
| Factory setting | Persistent |
|
|
| Maximum value | Expert |
|
|
|
|
|
|
EthMbScanTimeou | Modbus TCP I/O scanning timeout | s | UINT16 | CANopen 3044:2Dh |
t | Communication monitoring timeout for Mod- | 0.0 | UINT16 | Modbus 17498 |
| bus TCP. | 2.0 | UINT16 | Profibus 17498 |
| 60.0 | UINT16 | CIP 168.1.45 | |
| Value 0: Timeout monitoring disabled | |||
|
| R/W |
| |
|
|
|
| |
| In increments of 0.1 s. |
| per. |
|
| Changed settings become active immedi- |
| - |
|
|
|
|
| |
| ately. |
|
|
|
|
|
|
|
|
5.8Setting the web server
The web server is activated or deactivated by means of the parameter
EthWebserver.
▶If you do not want to use the web server, set the parameter
EthWebserver to "Off".
See chapter "6.3.1 Web server" for additional information on the web server.
| Parameter name | Description | Unit | Data type | Parameter address |
| HMI menu |
| Minimum value | R/W | via fieldbus |
| HMI name |
| Factory setting | Persistent |
|
|
|
| Maximum value | Expert |
|
|
|
|
|
|
|
01.2012 | EthWebserver | Ethernet webserver | - | UINT16 | CANopen 3044:6h |
| 1 / On: Ethernet webserver on | 0 | UINT16 | Modbus 17420 | |
| 1 | UINT16 | CIP 168.1.6 | ||
|
| 0 / Off: Ethernet webserver off | 1 | UINT16 | Profibus 17420 |
|
|
| |||
V1.01, |
| Changed settings become active the next |
| R/W |
|
| time the product is switched on. |
| per. |
| |
|
|
|
| ||
0198441113843, |
|
|
| - |
|
|
|
|
|
| |
|
|
|
|
|
49 |