Camera (Interior)

M

N

O

P

Q

R

S

T

*TK-C215VP4U/E is used in the above illustration

MRotation Knob ( TK-C215VP4U/E only)

Rotate the lens unit to adjust the inclination of the image. (A Pg. 25)

N Rotation Center Mark

(A Pg. 25)

O Fall Prevention Wire

Use this to connect the base G to the dome cover D.

P Camera Unit Fastening Screw  2

Use this to fasten the camera body R to the base G.

To remove (A Pg. 21)

Q [MONITOR]Monitor Terminal (RCA Jack)

(A Pg. 25)

R Camera Unit

S Connector for Power Supply of Heater

This is a power connector for use when the heater (sold separately: KA-ZH215) is mounted.

T Space for Heater

Memo:

When mounting the heater (sold separately: KA-ZH215), read the instruction manual of the heater carefully before mounting.

Lens

Y

(A next page)

 

X

 

W

V

U

U Camera Unit Fastening Clip  2

This clip is used for fastening the camera unit to the base. When removing the base, press toward the direction indicated by the arrow to release. (A Pg. 21)

V Tilt Fastening Screw

Upon adjusting the angle of view, tighten the screw to ensure that camera’s angle of view does not go out of alignment when it is used at a location with strong vibration. (A Pg. 25)

W Shooting Direction Mark

Install the camera by aligning the shooting direction with the arrow mark.

X Lug Plate

This plate is used for fastening the silica gel. (A Pg. 24)

Y Space for Silica Gel

(A Pg. 24)

11

Image 11
Contents For Customer Use TK-C215VP4U/E Instructions TK-C215VP12U/EIntroduction For USA and Canada Safety PrecautionsDear Customer Characteristics Table of Contents Others Precautions for proper use of this productStorage and Location of Use TK-C215VP12U/E only MaintenanceEnergy Conservation  Note on consumable partsCamera Name of PartsBase AC 24 V/DC 12 V Power Supply WireAlarm signal cable TK-C215VP12U/E only Video signal output connector BNCMemo Camera InteriorFunction selection switches AGC Auto-gain control switch Setting the Switches Lens TK-C215VP4U/ERESET/SPOT RESET/SPOT button B,+/- R/B,+/- adjustment buttonDAY/NIGHT Easy Day & Night switch Sync Synchronization system selection switchWHT.BAL. ATW/MANUAL selection switch BLC Backlight compensation switchPosition Select Position Select button Alarm Position status indication LEDB,+/- R/B, +/- adjustment button Trigger Alarm alarm input mode selection switchMetal Contact System ExampleAbout Connection Cables Video signal cablesDC 12 V or AC 24 V power supply cable ‹ Polarity of alarm signals Electrical Specifications of Alarm Input TerminalsRight sequence to connect and set the camera Removing the inner dome Setting the switchesSetting the switches Removing the dome coverRemoving the camera unit from the base SetupMounting the fall prevention wire to a firm place Mounting the baseCable Connection Connecting the coaxial cable a PgConnecting the AC 24 V/DC 12 V power supply wires Connect the alarm cable. TK-C215VP12U/E onlyA PgFastening the 2 fastening screws of the camera unit Mounting the camera unitFill the hole with sealing material Mounting the camera unit to the baseInserting the silica gel supplied Mounting the test monitor Adjusting the video imageAdjusting the shooting direction of the camera  TK-C215VP4U/E Adjusting the angle of view, focus and brightnessAdjusting the angle of view Adjusting the focusAdjusting the brightness  Registering home position Adjust the focusAdjust the brightness  TK-C215VP12U/E Registering alarm position Mounting the dome cover Mounting the inner domeFollowing procedures are same as normal mounting Mounting the camera using the electrical boxFastening the base to the ceiling Mounting the camera using the pipeMounting the fall prevention wire to a firm place a Pg Mounting the base to the pipeRemoving the plug for the piping hole of the base White-spot correction Page  Camera Specifications General  Lens Dimensional Outline Drawing Focus chart TK-C215VP4U/E TK-C215VP12U/E Dome Camera