JVC TK-C215VP4U/E, TK-C215VP12U/E manual Dear Customer

Page 4

Introduction

Safety Precautions (continued)

Attention:

This symbol is only valid in the European Union.

Information for Users on Disposal of Old Equipment [European Union]

This symbol indicates that the electrical and electronic equipment should not be disposed as general household waste at its end-of-life. Instead, the product should be handed over to the applicable collection point for the recycling of electrical and electronic equipment for proper treatment, recovery and recycling in accordance with your national legislation.

By disposing of this product correctly, you will help to conserve natural resources and will help prevent potential negative effects on the environment and human health which could otherwise be caused by inappropriate waste handling of this product. For more information about collection point and recycling of this product, please contact your local municipal office, your household waste disposal service or the shop where you purchased the product.

Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.

(Business users)

If you wish to dispose of this product, please visit our web page www.jvc-europe.com to obtain information about the take-back of the product.

[Other Countries outside the European Union]

If you wish to dispose of this product, please do so in accordance with applicable national legislation or other rules in your country for the treatment of old electrical and electronic equipment.

Dear Customer,

This apparatus is in conformance with the valid European directives and standards regarding electromagnetic compatibility and electrical safety.

European representative of Victor Commany of Japan Limited.is:

JVC Technology Centre Europe GmbH P.O.Box 10 05 52

61145 Friedberg Germany

The unit is to be powered by a DC 12 V or an AC 24 V power supply.

The unit is to be powered by a UL Listed DC 12 V or an AC 24 V power supply. (For U type)

The AC 24 V and 12 V DC power supply shall conform to the following: Class 2 only (For USA), Isolated power supply only (For Europe).

This installation should be made by a qualified service person and should conform to all local codes.

This installation shall be in accordance with the National Electrical Code, ANSI/NFPA 70.

Any Mention in this manual of Alarm inputs have not been evaluated by UL to be used for Burglar Alarm Functionality.

When mounting this unit to the ceiling or wall, mount it to a secure location where it can support the mass of this unit. When mounting to an insecure location, make sure to carry out reinforcement of the ceiling or wall before installation.

The rating label is placed on the bottom surface of the camera unit.

The camera unit may fall if the mounting screw or piping is not properly tightened. Ensure that the screws and nuts are properly tightened.

We do not accept liability for any damage to the camera in cases when it is dropped because of incomplete installation due to not observing the installation instructions correctly. Please be careful when installing the camera.

Do not install the camera near lighting equipment with a high temperature, such as spotlights. Doing so may cause malfunction or fire.

4

Image 4
Contents TK-C215VP4U/E Instructions TK-C215VP12U/E For Customer UseIntroduction Safety Precautions For USA and CanadaDear Customer Characteristics Table of Contents Storage and Location of Use Precautions for proper use of this productOthers Maintenance Energy Conservation Note on consumable parts TK-C215VP12U/E onlyName of Parts CameraAC 24 V/DC 12 V Power Supply Wire Alarm signal cable TK-C215VP12U/E onlyVideo signal output connector BNC BaseCamera Interior MemoSetting the Switches Lens TK-C215VP4U/E RESET/SPOT RESET/SPOT buttonB,+/- R/B,+/- adjustment button Function selection switches AGC Auto-gain control switchSync Synchronization system selection switch WHT.BAL. ATW/MANUAL selection switchBLC Backlight compensation switch DAY/NIGHT Easy Day & Night switchB,+/- R/B, +/- adjustment button Alarm Position status indication LEDPosition Select Position Select button Alarm alarm input mode selection switch TriggerSystem Example Metal ContactDC 12 V or AC 24 V power supply cable Video signal cablesAbout Connection Cables Electrical Specifications of Alarm Input Terminals ‹ Polarity of alarm signalsRight sequence to connect and set the camera Setting the switches Setting the switchesRemoving the dome cover Removing the inner domeSetup Mounting the fall prevention wire to a firm placeMounting the base Removing the camera unit from the baseConnecting the coaxial cable a Pg Connecting the AC 24 V/DC 12 V power supply wiresConnect the alarm cable. TK-C215VP12U/E onlyA Pg Cable ConnectionMounting the camera unit Fill the hole with sealing materialMounting the camera unit to the base Fastening the 2 fastening screws of the camera unitInserting the silica gel supplied Adjusting the shooting direction of the camera Adjusting the video imageMounting the test monitor Adjusting the angle of view, focus and brightness Adjusting the angle of viewAdjusting the focus  TK-C215VP4U/EAdjusting the brightness Adjust the focus Adjust the brightness TK-C215VP12U/E  Registering home position Registering alarm position Mounting the inner dome Mounting the dome coverMounting the camera using the electrical box Following procedures are same as normal mountingMounting the camera using the pipe Mounting the fall prevention wire to a firm place a PgMounting the base to the pipe Fastening the base to the ceilingRemoving the plug for the piping hole of the base White-spot correction Page Specifications  Camera Lens  General Dimensional Outline Drawing Focus chart TK-C215VP4U/E TK-C215VP12U/E Dome Camera