JVC TK-C215VP4U/E Alarm Position status indication LED, Position Select Position Select button

Page 14

Introduction

Setting the Switches and the Lens (TK-C215VP12U/E)

Set the video setting switches on the camera unit before mounting it.

To set the switches, use a fine-tipped screwdriver.

B [ZOOM / FOCUS,MEMORY] zoom, focus adjustment switches/position memory button

Use the [JTELE] and [KWIDE] switches to zoom, and the [HFAR] and [INEAR] switches to adjust focus. (A Pg. 28)

Press the [MEMORY] button to register the position. (A Pg. 28)

C [ALARM POSITION] status indication LED

A

 

B

ZOOM/FOCUS

C

 

D

POSITION

 

 

H

 

 

IRIS

 

LEVEL

WHT.BAL.

TELE

L

[MEMORY]

FAR

WIDE

NEAR

 

 

SELECT

ALARM

POSITION

R

B

 

8

 

7

 

6

 

5

4 4

3

2 2 1

PHASE

RESET/[SPOT]

LL

 

E F

G

Light off

: Registration of home

 

position is enabled

Light on (red)

: Lens initializing.

Light on (green)

: Registration of alarm

 

position is enabled

Blinking (green)

: Position memory

 

registration mode N

 

memory registration

 

completed

 

(A Pg. 28)

D [POSITION SELECT] POSITION SELECT button

Press this button to switch between the home and alarm positions. Display on the status indication LED C will change accordingly. (A Pg. 28)

E [RESET/SPOT] RESET/SPOT button

Function selection switch setting table (Items in bold are factory position)

 

 

OFF

ON

 

 

 

 

1

AGC

OFF

ON

2

SELECT

PHASE

WHT.BAL.

3

SYNC

LL

INT

4

WHT.BAL.

ATW

MANUAL

5

BLC

OFF

ON

6

DAY/NIGHT

OFF

ON

7

ALARM

TRIGGER

STATE

8

RESET/SPOT

RESET

SPOT

A [IRIS LEVEL] Iris level adjustment

For adjusting the level of the automatic aperture control lens. This adjustment only needs to be made when required. Use this to accommodate particular shooting conditions.

To darken image: Counterclockwise (L side)

To brighten image: Clockwise (H side)

Note:

Prior to adjusting the aperture level, ensure

to set the 1 [AGC] Switch of the function selection switch G to AOFFB. Otherwise, when the level is turned too far toward L, the AGC function activates increasing sensitivity and the picture may look uneven.

When switch #8 is set to [RESET] position and this button is pressed, the value of the white balance or phase adjusted manually is reset to the default value.

When switch 2 [SELECT] is set to [WHT.BAL.], the white balance is reset to the default value.

When the switch is set to PHASE, the phase is reset to the default value.

When switch #8 is set to SPOT:

When this button is pressed, white-spots are corrected.

For instructions on correcting white-spots, see AWhite-spot correctionB (A Pg. 34).

F[R/B,+/-] R/B, +/- adjustment button

This button is pressed when manually adjusting the white balance or when adjusting the vertical phase of the line lock.

The function of this button is selected using the 2 [SELECT] switch.

When manually adjusting the white balance: Press the R button to increase the red tint and decrease the blue tint.

Press the B button to increase the blue tint and decrease the red tint.

When adjusting the phase:

Press the + or - button to adjust the phase.

14

Image 14
Contents TK-C215VP4U/E Instructions TK-C215VP12U/E For Customer UseIntroduction Safety Precautions For USA and CanadaDear Customer Characteristics Table of Contents Others Precautions for proper use of this productStorage and Location of Use  Note on consumable parts MaintenanceEnergy Conservation TK-C215VP12U/E onlyName of Parts CameraVideo signal output connector BNC AC 24 V/DC 12 V Power Supply WireAlarm signal cable TK-C215VP12U/E only BaseCamera Interior MemoB,+/- R/B,+/- adjustment button Setting the Switches Lens TK-C215VP4U/ERESET/SPOT RESET/SPOT button Function selection switches AGC Auto-gain control switchBLC Backlight compensation switch Sync Synchronization system selection switchWHT.BAL. ATW/MANUAL selection switch DAY/NIGHT Easy Day & Night switchPosition Select Position Select button Alarm Position status indication LEDB,+/- R/B, +/- adjustment button Alarm alarm input mode selection switch TriggerSystem Example Metal ContactAbout Connection Cables Video signal cablesDC 12 V or AC 24 V power supply cable Electrical Specifications of Alarm Input Terminals ‹ Polarity of alarm signalsRight sequence to connect and set the camera Removing the dome cover Setting the switchesSetting the switches Removing the inner domeMounting the base SetupMounting the fall prevention wire to a firm place Removing the camera unit from the baseConnect the alarm cable. TK-C215VP12U/E onlyA Pg Connecting the coaxial cable a PgConnecting the AC 24 V/DC 12 V power supply wires Cable ConnectionMounting the camera unit to the base Mounting the camera unitFill the hole with sealing material Fastening the 2 fastening screws of the camera unitInserting the silica gel supplied Mounting the test monitor Adjusting the video imageAdjusting the shooting direction of the camera Adjusting the focus Adjusting the angle of view, focus and brightnessAdjusting the angle of view  TK-C215VP4U/EAdjusting the brightness  TK-C215VP12U/E Adjust the focusAdjust the brightness  Registering home position Registering alarm position Mounting the inner dome Mounting the dome coverMounting the camera using the electrical box Following procedures are same as normal mountingMounting the base to the pipe Mounting the camera using the pipeMounting the fall prevention wire to a firm place a Pg Fastening the base to the ceilingRemoving the plug for the piping hole of the base White-spot correction Page Specifications  Camera Lens  General Dimensional Outline Drawing Focus chart TK-C215VP4U/E TK-C215VP12U/E Dome Camera