Motorola I580 service manual Gps

Page 50

 

BASIC LEVEL TEST MODES AND PROCEDURES: Test Modes

 

 

 

Table 6-1. Display Screens (Continued)

 

 

 

Name

Description

 

 

 

 

N6:1 Intrcnct

Parameter details for the 6:1 Interconnect Feature enabling transmission of RF-originated

 

 

messages through the telephone system.

 

 

Line 1 shows MS, the Mobile Subscriber's ability to support 6:1 Interconnect and FNE, the

 

 

Fixed Network Equipment’s ability to support 6:1 Interconnect respectively. Numbers 0 or

 

 

1 indicate No or Yes respectively.

 

 

Line 2 shows I, Interleave of the current channel, O, Offset of the current channel, and S,

 

 

Sub-slot of the current channel. Values for Interleave are 1 – 24, Offset values are 0 – 23,

 

 

and Sub-slot can be A, B or N.

 

 

Line 3 shows ECC, Extended Color Code and PO, Primary Control Channel Offset of the

 

 

current carrier.

 

 

Values for ECC are 0 – 16. Values for PCCH Offset are 0 - 11.

 

 

During Trace Mode, radio activity such as interconnect, dispatch call, packet data session,

 

 

registration, or location update information will automatically update every 2 seconds.

 

 

 

 

N6:1 Dispatch

Displays status of a new 6:1 dispatch call. Data displayed shows “MS 1 FNE 1”. All other

 

 

data combinations are old 6:1 dispatches.

 

 

 

 

GPS

Displays the GPS location, time info, assist, navigation, summary, GPS version.

 

 

 

 

IMEI/SIM ID/SN

Displays the electronic serial number, SIM ID serial number, and unit serial number.

 

 

The IMEI is the global name assigned to the mobile station at manufacturing time and

 

 

should correspond to the serial-number tag of the unit.

 

 

The SIM ID is the SIM electronic serial number and should correspond with the number

 

 

stamped on the SIM card. The SN is applied during manufacturing.

 

 

Pressing OK allows the IMEI/SIM ID to be traced.

 

 

 

 

Registration Log

Displays the Dispatch Log, Interconnect Log, Packet Data Log, Mobile IP Log, and Phone

 

 

Rst Log. Registration Log information is updated when the user deselects and selects the

 

 

Registration Log choice.

 

 

 

 

Err/Channel

Displays the physical channel that the unit is connected to or the radio link procedure that

 

 

is currently active. Also, displays error codes encountered during normal operation if Err/

 

 

Channel is On. At power up, Err/Channel is Off.

 

 

 

 

Current Freq

Displays current frequency and band. Pressing OK allows the current frequency and band

 

 

to be traced.

 

 

 

 

Dispatch IDs

Displays the Dispatch Group ID affiliated with the unit in the current dispatch-location area.

 

 

Also, displays the Dispatch Individual ID affiliated with the unit in the current dispatch

 

 

location. Pressing OK allows the dispatch IDs to be displayed periodically.

 

 

 

 

Band Info

Displays primary and secondary bands.

 

 

 

 

Bandmap

Displays the currently selected regional bandmap. Pressing OK allows the bandmap to be

 

 

displayed periodically.

 

 

 

 

Hardware

Displays the AFC Offset and Channel Number.

 

 

Pressing OK allows the hardware parameters to be traced.

 

 

 

 

Fatal Err/#

Displays the Fatal Error log. This log contains a count of any fatal errors logged during the

 

 

unit's automatic self test. Optioning clear empties the log.

 

 

 

 

Flags:

Displays the error log. This log contains any errors logged by the unit software. Pressing

 

 

Menu when it appears displays the Clearall screen in which the user can clear all the logged

 

 

errors.

 

 

 

 

68P80401P05

35

Image 50
Contents IDEN Digital Multi-Service, Data-Capable Portable I580 Manual Revisions Safety and General Information Electro Magnetic Interference Compatibility Medical DevicesAccessory Safety Information Cleaning and Drying ConsiderationsSafety and General Information Model Information Model Numbering SystemModel Specifications General Receiver TransmitterContents Chapter Basic Level Test Modes and Procedures Chapter Field Level Test Modes and Procedures Appendix a Ordering Replacement Parts and Kits How This Manual Is Organized PrefaceWho Should Use This Manual Conventions Used in This Manual Related PublicationsOverview IDEN Digital Modulation TechnologySpectrum of iDEN Quad 16QAM IDEN Voice Compression Technology RF Transmission BurstsCalling Area Coverage MOTOtalk Bluetooth Wireless SystemGlobal Positioning System GPS Section To remove a SIM card Figure SIM CardsRemoving and Inserting a SIM Card Removing a SIM Card To insert a SIM card FigureFEATURES, ICONS, and Indicators I580 FeaturesDisplay Icons Main Menu IconsStatus Icons Power-Up Sequence DISPLAYS, MESSAGES, and AlertsSelf-Test Reset Errors Power-Down SequenceSelf-Test Errors MessagesService Messages Service MessagesAlert Tones Alert TonesAlert Tones Alert Tones To set unit to vibrate for all calls Using the Optional Vibrate FunctionVibrator Settings From the main menu, select Settings 2-Way Radio Alert Type Test Equipment Preparing for Basic Level TestingReference Accessories Reference UnitCustomer Care Reset ConditionBasic Level Checks and Self Tests Test ConditionsBasic-Level Test Checklist Basic-Level Test ChecklistPreventive Maintenance To clean the unit takes approximately 3 minutesShock and Pressure test time is approximately 3 minutes Mechanical and Electrical ChecksSIM Card Swap Test SIM Card Swap test time is approximately 5 minutesLockup Test Accessory Swap TestAccessory Swap test time is approximately 5 minutes Lockup Test time is approximately 6 minutesBattery Connections test time is approximately 5 minutes Battery Connections TestTesting the GPS Receiver To test the GPS ReceiverVoltage Recognition test time is approximately 4 minutes Self-Test ProceduresVoltage Recognition Test Passcode test time is approximately 5 minutes Programming Menu Settings CheckPasscode Test From the main menu, select Settings Display/Info Contrast Phone Calls FeaturesWay Radio Options Personalize Volume FeaturesSecurity Features From the main menu, select Settings Security GPS PIN Advanced Features Call Performance TestCall Performance test time is approximately 7 minutes To enter Debug/Trace Mode Basic Level Test Modes and ProceduresEntering Debug Mode Test ModesTrace Mode Display Screens Display ScreensGPS To enter Test Mode Test Mode Test ProceduresEntering Test Mode Audio Loopback TestAudio Loopback test time is approximately 3 minutes ESN and Imei Matching TestDebug Check ESN/IMEI Matching test time is approximately 6 minutesTo monitor the data in the unit 68P80401P05 Technician Test Procedures Connecting the Unit to the RSS Workstation Programming the i580 UnitCodeplug Help Codeplug TroubleshootingTo access the codeplug Help topic in Windows Preparing for Field Level Testing Preparing Equipment for TestingUsing RSS Connecting an iDEN Unit to the R-2660Typical R-2660 Setup To connect the unit to the R-2660RF Zone Fields and Values To enter Initial Registration modeOperating the R-2660 Disassembling and Reassembling the Unit Disassembly Sequence FlowchartAssembly/Disassembly Procedures Remove Remove Battery CoverInstall Remove Battery Remove SIM Card Remove AntennaPreparing for Field Level Testing Remove Antenna Remove Back Housing Remove Main Board, Keypad Remove Flip Assembly Procedure to remove flip assemblyPreparing for Field Level Testing Remove Flip Assembly Install Flip Assembly Procedure to install flip assemblyPreparing for Field Level Testing Install Flip Assembly Exploded View and Parts List I580 Component Parts ListI580 Exploded View Field Level Test Modes and Procedures Field-Level Test Checklist Required Test EquipmentField-Level Test Checklist Done Technical Tests Pass FailSee the Strong Signal Environment section Registration/Call TestSignal Quality Error SQE Test R-2660TX Power Test See Entering Test Mode Press Menu, EditBit Error Rate BER Test PassPower-Up Test Keypad Test Audio Test Use this test to check the audio portion of the unitReset Test ResetReset Log Test To perform the reset log testModel Assembly MA Test Mode Test GPS Global Positioning System Receiver Test Use this test on a unit to check its GPS functionalityYes Bluetooth Test This Page intentionally left blank Mechanical Parts Rework and Repair Recommended EquipmentRework/Repair Requirements Recommended ToolsRecommended Supplies Board Preparation Components IdentificationLand Preparation Procedure Mechanical Parts Rework ProcedureRemoval Procedure Installation Procedure5 J752 Audio Jack 4 J600 RF Connector6 J401 30 Pin Board-to-Flex Connector 9 M105 Battery Contact 7 J400 80 Pin Board-to Flex Connector8 M002 Simm Connector 11 J753 Microphone Socket SW-all Key/Switch10 M2 2 Pin-Contact 13 D401 through D412 LED Replacement Parts Ordering Replacement Parts and KitsCustomer Service Domestic OrdersReplacement Kits Table A-1Mid Rate Travel Chargers Bluetooth Accessories NNTN2344 NA Table A-2. Recommended Test Equipment and Tools Recommended Test Equipment and ToolsRecommended Programming Equipment Table A-3. Recommended Programming EquipmentTable A-4. Recommended Software TTY@68P80401P05@
Related manuals