BASIC LEVEL CHECKS AND SELF TESTS: Mechanical and Electrical Checks
4.Replace the SIM card with the test (reference) SIM card. Ensure the test SIM card is clean.
5.Power on the unit, and verify that the test SIM card works with the unit.
If the unit works, the customer’s SIM card is defective and should be replaced, or the problem is due to operator error, system, or carrier. If the unit does not work, the unit is defective and should be sent to the iDEN Radio Support Center.
NOTE: If a defective SIM card is replaced with a new card or test card, all personal information (voice notes, datebook entries, etc.) that was stored on the original card will be lost.
6.Install the customer’s SIM card in a test (reference) unit.
If the test unit works, the customer’s unit is defective and should be sent to the iDEN Radio Support Center
5.5.2Accessory Swap Test
Use this test to determine if the unit’s accessories are defective.
NOTE: When adding or removing accessories, the main screen displays “Device Attached” or “Device Detached” and the external screen displays a similar message.
The Accessory Swap test time is approximately 5 minutes:
1.Remove the accessory and check the contact areas for foreign material, damage, or other defects.
2.Replace the problem accessory with the reference accessory.
3.Verify the reference accessory works with the unit.
If the reference accessory works, the customer’s accessory is defective and should be replaced.
4.Verify the customer’s accessory works with a reference unit.
If the accessory works, the customer’s unit is defective and should be sent to the iDEN Radio Support Center.
5.5.3Lockup Test
Use this test to determine if the unit locks up when keys are pressed or when it is powered down.
The Lockup Test time is approximately 6 minutes:
1.Power up the unit.
2.Press End Call to clear display inputs.
68P80401P05 | 23 |