Table 3-4. Alert Tones (Continued)

Tone

Low

High

Freq

Cadence

When Tone Occurs

 

 

 

 

 

 

Group Call Alert

Spkr

Spkr

2300H

2x (150ms off+150ms on)

Group call received

 

 

 

z

 

 

 

 

 

 

 

 

In Service

Spkr

Spkr

2300H

1x50ms on

Entering in-service mode

 

 

 

z

 

 

 

 

 

 

 

 

Interconnect Busy

Ear

Ear

480/

1s off + 1s on 480Hz;

Interconnect channel or line is

 

 

 

620Hz

1s off +1s on 620Hz continuous

busy

 

 

 

 

 

 

Invalid Key

Ear

Ear

900Hz

1x80ms on

Invalid key pressed

 

 

 

 

 

 

Low Battery in Idle

Spkr

Spkr

2300H

24ms on+24ms off + 24ms on+240

Battery below preset value.

 

 

 

z

ms off + 24ms on+24ms off + 24ms

(Tone sounds from earpiece if

 

 

 

 

on+30ms off every 30 seconds

in low audio during a dispatch

 

 

 

 

 

or interconnect call.)

 

 

 

 

 

 

Keypad Volume

Ear

Ear

1800H

Continuous

Keypad volume changed on

Set

 

 

z

 

quiet channel or in

 

 

 

 

 

Programming Menu

 

 

 

 

 

 

Message Mail

Spkr

Spkr

2400/

8x(64ms on 2400Hz + 64ms on

Message mail received while

Received in Idle

 

 

2743H

2743Hz)every 30 seconds

unit is idle

 

 

 

z

 

 

 

 

 

 

 

 

Msg Mail

Ear

Ear

2400/

8x(64ms on 2400Hz + 64ms on

Message mail received while

Received in

 

 

2743H

2743Hz) every 30 seconds

unit is in interconnect mode

Interconnect

 

 

z

 

 

 

 

 

 

 

 

Message Volume

Spkr

Spkr

2400/

8x(64ms on 2400Hz + 64ms on

Message volume changed on

Set

 

 

2743H

2743Hz) continuous

quiet channel or in

 

 

 

z

 

Programming Menu

 

 

 

 

 

 

Net Alert

Ear

Spkr

880Hz,

5x (50ms on 880Hz + 50ms on

Net alert received while in idle

 

 

 

1760H

1760Hz) 8x (50ms on 330Hz +

 

 

 

 

z/

50ms on 990Hz) repeated every

 

 

 

 

330Hz,

750ms

 

 

 

 

990Hz

 

 

 

 

 

 

 

 

One Minute Beep

Ear

Ear

2300H

1x 50ms on

During interconnect calls

 

 

 

z

 

 

 

 

 

 

 

 

Phone Fast Busy

Ear

Ear

480/

0.25s on+0.25s off 480Hz 0.25s

Call failed (system busy, out of

 

 

 

620Hz

on+0.25s off 620Hz continuous

service, or trouble with

 

 

 

 

 

network)

 

 

 

 

 

 

Phone Redial Alert

Spkr

Spkr

2091/

14x(24ms on 2091Hz + 24ms on

Phone redial successful

 

 

 

2556H

2556Hz)

 

 

 

 

z

 

 

 

 

 

 

 

 

68P80401P05

15

Image 30
Contents IDEN Digital Multi-Service, Data-Capable Portable I580 Manual Revisions Safety and General Information Electro Magnetic Interference Compatibility Medical DevicesAccessory Safety Information Cleaning and Drying ConsiderationsSafety and General Information Model Information Model Numbering SystemModel Specifications General Receiver TransmitterContents Chapter Basic Level Test Modes and Procedures Chapter Field Level Test Modes and Procedures Appendix a Ordering Replacement Parts and Kits Preface Who Should Use This ManualHow This Manual Is Organized Conventions Used in This Manual Related PublicationsOverview IDEN Digital Modulation TechnologySpectrum of iDEN Quad 16QAM IDEN Voice Compression Technology RF Transmission BurstsCalling Area Coverage Bluetooth Wireless System Global Positioning System GPS SectionMOTOtalk SIM Cards Removing and Inserting a SIM CardTo remove a SIM card Figure Removing a SIM Card To insert a SIM card FigureFEATURES, ICONS, and Indicators I580 FeaturesDisplay Icons Main Menu IconsStatus Icons Power-Up Sequence DISPLAYS, MESSAGES, and AlertsSelf-Test Reset Errors Power-Down SequenceSelf-Test Errors MessagesService Messages Service MessagesAlert Tones Alert TonesAlert Tones Alert Tones Using the Optional Vibrate Function Vibrator SettingsTo set unit to vibrate for all calls From the main menu, select Settings 2-Way Radio Alert Type Test Equipment Preparing for Basic Level TestingReference Accessories Reference UnitCustomer Care Reset ConditionBasic Level Checks and Self Tests Test ConditionsBasic-Level Test Checklist Basic-Level Test ChecklistPreventive Maintenance To clean the unit takes approximately 3 minutesShock and Pressure test time is approximately 3 minutes Mechanical and Electrical ChecksSIM Card Swap Test SIM Card Swap test time is approximately 5 minutesLockup Test Accessory Swap TestAccessory Swap test time is approximately 5 minutes Lockup Test time is approximately 6 minutesBattery Connections test time is approximately 5 minutes Battery Connections TestTesting the GPS Receiver To test the GPS ReceiverSelf-Test Procedures Voltage Recognition TestVoltage Recognition test time is approximately 4 minutes Programming Menu Settings Check Passcode TestPasscode test time is approximately 5 minutes From the main menu, select Settings Display/Info Contrast Phone Calls FeaturesWay Radio Options Volume Features Security FeaturesPersonalize From the main menu, select Settings Security GPS PIN Advanced Features Call Performance TestCall Performance test time is approximately 7 minutes To enter Debug/Trace Mode Basic Level Test Modes and ProceduresEntering Debug Mode Test ModesTrace Mode Display Screens Display ScreensGPS To enter Test Mode Test Mode Test ProceduresEntering Test Mode Audio Loopback TestAudio Loopback test time is approximately 3 minutes ESN and Imei Matching TestDebug Check ESN/IMEI Matching test time is approximately 6 minutesTo monitor the data in the unit 68P80401P05 Technician Test Procedures Connecting the Unit to the RSS Workstation Programming the i580 UnitCodeplug Troubleshooting To access the codeplug Help topic in WindowsCodeplug Help Preparing for Field Level Testing Preparing Equipment for TestingUsing RSS Connecting an iDEN Unit to the R-2660Typical R-2660 Setup To connect the unit to the R-2660To enter Initial Registration mode Operating the R-2660RF Zone Fields and Values Disassembly Sequence Flowchart Assembly/Disassembly ProceduresDisassembling and Reassembling the Unit Remove Battery Cover InstallRemove Remove Battery Remove SIM Card Remove AntennaPreparing for Field Level Testing Remove Antenna Remove Back Housing Remove Main Board, Keypad Remove Flip Assembly Procedure to remove flip assemblyPreparing for Field Level Testing Remove Flip Assembly Install Flip Assembly Procedure to install flip assemblyPreparing for Field Level Testing Install Flip Assembly Exploded View and Parts List I580 Component Parts ListI580 Exploded View Field Level Test Modes and Procedures Field-Level Test Checklist Required Test EquipmentField-Level Test Checklist Done Technical Tests Pass FailSee the Strong Signal Environment section Registration/Call TestSignal Quality Error SQE Test R-2660TX Power Test See Entering Test Mode Press Menu, EditBit Error Rate BER Test PassPower-Up Test Keypad Test Audio Test Use this test to check the audio portion of the unitReset Test ResetReset Log Test To perform the reset log testModel Assembly MA Test Mode Test GPS Global Positioning System Receiver Test Use this test on a unit to check its GPS functionalityYes Bluetooth Test This Page intentionally left blank Mechanical Parts Rework and Repair Recommended EquipmentRecommended Tools Recommended SuppliesRework/Repair Requirements Board Preparation Components IdentificationLand Preparation Procedure Mechanical Parts Rework ProcedureRemoval Procedure Installation Procedure4 J600 RF Connector 6 J401 30 Pin Board-to-Flex Connector5 J752 Audio Jack 7 J400 80 Pin Board-to Flex Connector 8 M002 Simm Connector9 M105 Battery Contact SW-all Key/Switch 10 M2 2 Pin-Contact11 J753 Microphone Socket 13 D401 through D412 LED Replacement Parts Ordering Replacement Parts and KitsCustomer Service Domestic OrdersReplacement Kits Table A-1Mid Rate Travel Chargers Bluetooth Accessories NNTN2344 NA Table A-2. Recommended Test Equipment and Tools Recommended Test Equipment and ToolsRecommended Programming Equipment Table A-3. Recommended Programming EquipmentTable A-4. Recommended Software TTY@68P80401P05@