Motorola I580 service manual Bit Error Rate BER Test, Pass

Page 81

FIELD LEVEL TEST MODES AND PROCEDURES: Bit Error Rate (BER) Test

8.7Bit Error Rate (BER) Test

Use this test on a unit having any of the following symptoms: resets (RAAAA Type), No Service failures.

Set up the R-2660 for iDEN BER Test, and connect the unit to the RF IN/OUT connector.

Connect the battery eliminator to the unit. Remove the antenna. Set power supply between 5.0 and 12.0 Vdc.

Notes:

1.Confirm the reset log has errors.

2.Place the unit into Test Mode for this test.

3.Watch the unit for resetting during this procedure.

4.Verify the R-2660 has been calibrated and cable continuity is good.

5.In the United States, the Main board can only be replaced and programmed at the factory or iDEN Radio Support Center.

6.The Power, MPX, and MOD test parameters are for factory use only and should not be adjusted by field service personnel (see page 7-2 for default values).

Power up the unit. Enter Test Mode.

Do the following:

1.Press the Menu key, and then the Edit option key.

2.Press the Change option key, and scroll down to 800BER1.

3.Press Select to select the test.

4.Press the Back key, and then press Menu.

The monitor frequency is 806.0125 (Carr#1) for BER1.

Press Start

on unit. Press TX ON. The

RX BER that appears on the display Fail should be 0.0% at -70 dBm. Verify that

the TX BER on the R-2660

is < 0.07%.

Pass

Replace the

Main board, and

repeat the test.

 

 

 

Note: Ensure that the maximum cable

Lower

loss does not exceed 2 dB.

 

 

Gen: to -109 dBm

 

 

 

 

 

 

 

and check the RX BER in the

Fail

 

 

 

 

 

 

Replace the

 

 

 

 

display. The BER should be less than 10%

 

 

 

 

 

 

 

Main board, and

 

when at Gen: -109 dBm. (Freq

 

 

 

 

 

 

 

 

 

repeat the test.

 

Error should be less

 

 

 

 

 

 

 

 

 

 

 

 

 

than 200 Hz.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pass

Repeat the

above test using

800BER2, 800BER3,

800BER4; 900BER1, 900BER2,

and 900BER3 in Test Mode.

The monitor frequency is 813.5125

 

Fail

 

 

 

 

Replace the

 

(Carr#601) for 800BER2, 820.9875 (Carr#1199)

 

 

 

 

Main board, and

 

 

 

 

 

 

 

 

 

for 800BER3, and 824.9875 for 800BER4.

 

 

 

 

 

 

 

repeat the test.

 

The monitor frequency is 896.01875 for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

900BER1, 898.51875 for

 

 

 

 

 

 

 

 

 

 

Pass

 

 

 

 

 

 

 

 

 

 

900BER2 and

 

 

 

 

 

 

 

 

 

 

900.98125 for

Note: Change offset on R2660 to +39 MHz for 900

900BER3.

MHz (900BER1, 900BER2, and 900BER3).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit passed test. Look for system, cover-

 

 

 

 

 

 

age, accessory, or software problems.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

66

68P80401P05

Image 81
Contents IDEN Digital Multi-Service, Data-Capable Portable I580 Manual Revisions Safety and General Information Medical Devices Electro Magnetic Interference CompatibilityCleaning and Drying Considerations Accessory Safety InformationSafety and General Information Model Numbering System Model InformationGeneral Receiver Transmitter Model SpecificationsContents Chapter Basic Level Test Modes and Procedures Chapter Field Level Test Modes and Procedures Appendix a Ordering Replacement Parts and Kits Preface Who Should Use This ManualHow This Manual Is Organized Related Publications Conventions Used in This ManualIDEN Digital Modulation Technology OverviewSpectrum of iDEN Quad 16QAM RF Transmission Bursts IDEN Voice Compression TechnologyCalling Area Coverage Bluetooth Wireless System Global Positioning System GPS SectionMOTOtalk SIM Cards Removing and Inserting a SIM CardTo remove a SIM card Figure To insert a SIM card Figure Removing a SIM CardI580 Features FEATURES, ICONS, and IndicatorsMain Menu Icons Display IconsStatus Icons DISPLAYS, MESSAGES, and Alerts Power-Up SequenceSelf-Test Errors Power-Down SequenceSelf-Test Reset Errors MessagesService Messages Service MessagesAlert Tones Alert TonesAlert Tones Alert Tones Using the Optional Vibrate Function Vibrator SettingsTo set unit to vibrate for all calls From the main menu, select Settings 2-Way Radio Alert Type Reference Accessories Preparing for Basic Level TestingTest Equipment Reference UnitBasic Level Checks and Self Tests Reset ConditionCustomer Care Test ConditionsPreventive Maintenance Basic-Level Test ChecklistBasic-Level Test Checklist To clean the unit takes approximately 3 minutesSIM Card Swap Test Mechanical and Electrical ChecksShock and Pressure test time is approximately 3 minutes SIM Card Swap test time is approximately 5 minutesAccessory Swap test time is approximately 5 minutes Accessory Swap TestLockup Test Lockup Test time is approximately 6 minutesTesting the GPS Receiver Battery Connections TestBattery Connections test time is approximately 5 minutes To test the GPS ReceiverSelf-Test Procedures Voltage Recognition TestVoltage Recognition test time is approximately 4 minutes Programming Menu Settings Check Passcode TestPasscode test time is approximately 5 minutes Phone Calls Features From the main menu, select Settings Display/Info ContrastWay Radio Options Volume Features Security FeaturesPersonalize From the main menu, select Settings Security GPS PIN Call Performance Test Advanced FeaturesCall Performance test time is approximately 7 minutes Entering Debug Mode Basic Level Test Modes and ProceduresTo enter Debug/Trace Mode Test ModesDisplay Screens Trace Mode Display ScreensGPS Entering Test Mode Test Mode Test ProceduresTo enter Test Mode Audio Loopback TestDebug Check ESN and Imei Matching TestAudio Loopback test time is approximately 3 minutes ESN/IMEI Matching test time is approximately 6 minutesTo monitor the data in the unit 68P80401P05 Technician Test Procedures Programming the i580 Unit Connecting the Unit to the RSS WorkstationCodeplug Troubleshooting To access the codeplug Help topic in WindowsCodeplug Help Preparing Equipment for Testing Preparing for Field Level TestingConnecting an iDEN Unit to the R-2660 Using RSSTo connect the unit to the R-2660 Typical R-2660 SetupTo enter Initial Registration mode Operating the R-2660RF Zone Fields and Values Disassembly Sequence Flowchart Assembly/Disassembly ProceduresDisassembling and Reassembling the Unit Remove Battery Cover InstallRemove Remove Battery Remove Antenna Remove SIM CardPreparing for Field Level Testing Remove Antenna Remove Back Housing Remove Main Board, Keypad Procedure to remove flip assembly Remove Flip AssemblyPreparing for Field Level Testing Remove Flip Assembly Procedure to install flip assembly Install Flip AssemblyPreparing for Field Level Testing Install Flip Assembly I580 Component Parts List Exploded View and Parts ListI580 Exploded View Field Level Test Modes and Procedures Required Test Equipment Field-Level Test ChecklistDone Technical Tests Pass Fail Field-Level Test ChecklistRegistration/Call Test See the Strong Signal Environment sectionR-2660 Signal Quality Error SQE TestSee Entering Test Mode Press Menu, Edit TX Power TestPass Bit Error Rate BER TestPower-Up Test Keypad Test Use this test to check the audio portion of the unit Audio TestReset Reset TestTo perform the reset log test Reset Log TestModel Assembly MA Test Mode Test Use this test on a unit to check its GPS functionality GPS Global Positioning System Receiver TestYes Bluetooth Test This Page intentionally left blank Recommended Equipment Mechanical Parts Rework and RepairRecommended Tools Recommended SuppliesRework/Repair Requirements Components Identification Board PreparationRemoval Procedure Mechanical Parts Rework ProcedureLand Preparation Procedure Installation Procedure4 J600 RF Connector 6 J401 30 Pin Board-to-Flex Connector5 J752 Audio Jack 7 J400 80 Pin Board-to Flex Connector 8 M002 Simm Connector9 M105 Battery Contact SW-all Key/Switch 10 M2 2 Pin-Contact11 J753 Microphone Socket 13 D401 through D412 LED Customer Service Ordering Replacement Parts and KitsReplacement Parts Domestic OrdersTable A-1 Replacement KitsMid Rate Travel Chargers Bluetooth Accessories NNTN2344 NA Recommended Programming Equipment Recommended Test Equipment and ToolsTable A-2. Recommended Test Equipment and Tools Table A-3. Recommended Programming EquipmentTTY Table A-4. Recommended Software@68P80401P05@