NOTICE
Failure to follow the lubrication practices outlined in this manual could lead to pre- mature failure of your mill and void the war- ranty.
One-Shot Oiler
Lubricant | Frequency | Qty |
ISO 68 Lubricant or | Every | 1 |
Equivalent | 8 Hours | Pump |
| of Operation |
|
|
|
|
The oil lines running from the
Use the sight glass on the front of the oiler to make sure it is full, then pull the handle (see Figure 54) and release it to send lubricant through the lines.
Fill Cap
Oil Line
Pump
Handle
Figure 54. One-shot oiler.
Quill Gearing
Lubricant | Frequency | Qty |
ISO 68 Lubricant or | Every | 5 |
Equivalent | 8 Hours | Drops |
| of Operation |
|
|
|
|
Lift the cap of the oil cup shown in Figure 55 to add the lubricant.
Quill Gearing
Oil Cup
Figure 55. Quill gearing oil cup.
Vertical Bevel Gears
Lubricant | Frequency | Qty |
NLGI #2 Grease | Every | Thin |
| 40 Hours | Coat |
| of Operation |
|
|
|
|
Raise the knee up to access the vertical bevel gears underneath the saddle, then clean and lubricate the bevel gears shown in Figure 56.
Bevel Gears