WARNING |
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
HEATING ELEMENT &
TEMPERATURE SENSOR
Heating ![]()
Element
Temperature
Sensor Connector
Refer to page
1.Unplug washer or disconnect power.
2.Disconnect the wire connectors from the heating element and temperature sensor terminals.
3.Set the ohmmeter to the R x 1 scale.
4.Touch the ohmmeter test leads to the two
heating element terminals. The meter should indicate between 10 and 20 Ω.
5.Disconnect the heating element tempera- ture sensor connector from the CCU.
6.Touch the ohmmeter test leads to the two temperature sensor connector terminals. The meter should indicate as shown in the following chart.
Temperature | Results |
|
|
| ||
32°F (0°C) | 35.9K ohms |
|
|
| ||
|
|
| ||||
86°F (3°C) | 9.7K | ohms |
|
|
| |
104°F (40°C) | 6.6K | ohms |
|
|
| |
2 | 1 | |||||
|
|
| ||||
122°F (50°C) | 4.6K | ohms | ||||
|
|
| ||||
|
|
|
|
|
| |
140°F (60°C) | 3.2K | ohms |
|
|
| |
|
|
|
|
|
| |
158°F (70°C) | 2.3K | ohms |
|
|
| |
|
|
|
|
| ||
203°F (95°C) | 1K ohms |
|
|
| ||