DIAGNOSTIC TEST
The washer must be empty and the control must be in the OFF state before pressing the touchpad sequence to start the test.
Starting the Test Mode
•Close the door.
•Push CONTROL/ON (if present on this model).
•Select the DRAIN/SPIN cycle.
•Select NO SPIN by pressing the SPIN SPEED touchpad.
•Push PREWASH OPTION four times within five seconds. (If PREWASH OPTION is not present on this model, press RINSE HOLD four times within five seconds.) C:00 will light up on the display.
If the Starting procedure fails, push the PAUSE/CANCEL touchpad, then repeat the starting procedure.
Test Program Control
In order to advance to the next step of the test procedure, push PREWASH OPTION touchpad two times. If PREWASH OPTION is not present on this model, press RINSE HOLD two times.
Indication | Control Action | Actuators To Be Checked | |
|
|
| |
C:00 | Door locks. | • Door lock system | |
|
|
| |
C:01 | Fill by cold water inlet valve. | • Flowmeter | |
• Cold water inlet valve | |||
|
| ||
C:02 | Distribution system is set to Prewash position. | • Dispenser motor | |
|
| • Dispenser contact | |
|
|
| |
C:03 | Fill by hot water inlet valve. | • Hot water inlet valve | |
|
|
| |
C:04 | Drum rotates clockwise at wash speed. | • Motor | |
• Motor Control (MCU) | |||
|
| ||
|
|
| |
C:05 | Heater (if present on this model) is switched ON. | • Heater (if present on this model) | |
| Drum rotates clockwise at wash speed. | • NTC | |
| If there is not enough water in the tub, the water inlet |
| |
| valve will be switched ON to achieve the minimum |
| |
| water volume. |
| |
|
|
| |
C:06 | Drain pump is ON. | • Drain pump | |
|
|
| |
C:07 | Drum rotates counterclockwise from 35 to 90 rpm | • Motor | |
| within 15 seconds. | • Motor Control (MCU) | |
|
|
| |
C:08 | Drum rotates counterclockwise at maximum speed. | • Motor | |
| - If max. speed =EXTRA HIGH, drum speed = | • Motor Control (MCU) | |
| >1000 rpm. |
| |
| - If max. speed =HIGH, drum speed = >800 |
| |
| rpm. |
| |
|
|
|