LG Electronics 3828EL3010Y, D2702W, D2702V Special Requirements for Manufactured or Mobile Homes

Page 23

SPECIAL REQUIREMENTS FOR MANUFACTURED OR MOBILE HOMES

Any installation in a manufactured or mobile home must comply with the Manufactured Home Construction and Safety Standards Title 24 CFR, Part 32-80 or Standard CAN/CSA0Z240 MH and local codes and ordinances. If you are uncertain whether your proposed installation will comply with these standards, please contact a service and installation professional for assistance.

A gas dryer must be permanently attached to the floor.

The electrical connection for an electric dryer must be a 4-wire connection. More detailed information concerning the electrical connection is provided in the section Connecting Electric Dryers.

To reduce the risk of combustion and fire, the dryer must be vented to the outside.

DO NOT vent the dryer under a manufactured home or mobile home.

Electric dryers may be vented to the outside using the back, left, right, or bottom panel.

Gas dryers may be vented to the outside using the back, left, or bottom panel. Gas dryers may not be vented to the outside using the right side panel because of the burner housing.

The dryer exhaust duct must be affixed securely to the manufactured or mobile home structure, and the exhaust duct must be made of a material that will resist fire and combustion.

It is recommended that you use a rigid or flexible metal duct.

DO NOT connect the dryer exhaust duct to any other duct, vent, chimney, or other exhaust duct.

Make sure the dryer has adequate access to outside fresh air to ensure proper operation. The opening for outside fresh air must be at least 25 in2 (163 cm2).

It is important that the clearance of the duct from any combustible construction be at least 2 in. (5 cm), and when venting the dryer to the outdoors, the dryer can be installed with a clearance of 1 in. (2.5 cm) at the sides and back of the dryer.

Please be aware that venting materials are not supplied with the dryer. You should obtain the venting materials necessary for proper installation.

FINAL INSTALLATION CHECK

Once you have completed the installation of the dryer and it is in its final location, confirm proper operation with the following tests and Duct Condition Testing on the following page.

Testing Dryer Heating

GAS MODELS

Close the dryer door, press the ON/OFF switch to turn the dryer on, and start the dryer on a heat setting. When the dryer starts, the igniter should ignite the main burner.

NOTE: If all air is not purged from the gas line, the gas igniter may turn off before the main burner ignites. If this happens, the igniter will reattempt gas ignition after approximately two minutes.

ELECTRIC MODELS

Close the dryer door, press the ON/OFF switch to turn the dryer on, and start the dryer on a heat setting. The exhaust air should be warm after the dryer has been operating for 3 minutes.

Checking Airflow

Effective dryer operation requires proper airflow. The adequacy of the airflow can be measured by evaluating the static pressure. Static pressure in the exhaust duct can be measured with

a manometer, placed on the exhaust duct approximately 2 ft. (60.9 cm) from the dryer. Static pressure in the exhaust duct should not exceed 0.6 in. (1.5 cm). The dryer should be checked while the dryer is running with no load.

Checking Levelness

Once the dryer is in its final location, recheck the dryer to be sure it is level. Make sure it is level front to back and side to side, and that all 4 leveling feet are firmly on the floor.

23

Image 23
Contents Lgcanada DLE2701W DLG2702W DLE2701V DLG2702VImportant Safety Instructions Installation InstructionsRead ALL Instructions Before USE Basic Safety PrecautionsCalifornia Safe Drinking Water and Toxic Enforcement ACT What to do if YOU Smell GASGrounding Instructions Safety Instructions for InstallationSafety Instructions for Installation Safety Instructions for Connecting Electricity EASY-TO-USE Control Panel Special FeaturesEASY-ACCESS REvERSIBLE Door Flow Sense Duct Blockage Sensing System IndicatorLeveling Feet Rear of Dryer Included AccessoriesKEY Parts and Components FRONT-MOUNT Lint FilterClearances Choose the Proper LocationPedestal sold separately Stacking Kit sold separately Installation with Optional Pedestal Base or Stacking KITOptional Accessories REvERSING the Door Swing LEvELING the Dryer WWARNINGOption 2 Bottom Venting Option 1 Side VentingVENTING the Dryer Incorrect Venting Routing and Connecting DuctworkDuctwork Correct VentingSupply line requirements Connecting GAS DryersElectrical Requirements for Gas Models Only Electrical Connection ConnecTING GAS DryersConnecting the Gas Supply High-Altitude InstallationsElectrical Requirements for Electric Models Only Connecting Electric DryersFour-Wire Connection for Electric Dryers Power Cord Connecting Electric DryersUse UL-listed4-wire #10 AWG-minimum copper conductor cable Four-Wire Connection for Electric Dryers Direct WireThree-Wire Connection for Electric Dryers Power Cord Use UL-listed3-wire #10 AWG-minimum copper conductor cable Three-Wire Connection for Electric Dryers Direct WireChecking Airflow Final Installation CheckTesting Dryer Heating Special Requirements for Manufactured or Mobile HomesCorrect Venting Restricted or Blocked Airflow To activate the flow check Duct condition testFabric Care Labels Sorting LoadsLoading the Dryer Check the Lint Filter Before Every LoadControl Panel Features Sensor Dry Cycles Manual Dry Cycles Cycle GuideDisplay Cycle Completion Indicator with Check Filter ReminderChild Lock Indicator Cycle GuideOperating the Dryer DRY LEvEL Cycle Setting ButtonsTo Add Cycle Options to a Cycle To Install the Drying RackCycle Option buttons To Recall a Custom Program Special FunctionsCustom Program To Save a Custom ProgramCleaning Around and Under the Dryer Regular CleaningCleaning the Exterior Cleaning the Lint Filter Cleaning the InteriorProblem Possible Causes Solutions Before Calling for SERvICEFlow Sense Stacking Kit Color PedestalStacking Kit Pedestal ColorTools Needed for Installation Pedestal InstallationPedestal accessory includes Pedestal Installation This stacking kit includes Stacking KIT InstallationKEY Dimensions and Specifications Stacking KIT InstallationProduct Registration Information LG ELECTRONICS, INC LG Dryer Limited Warranty Canada Page ¡GRACIAS Precauciones básicas de seguridad LEA Todas LA Instrucciones Antes DE UsarQUÉ Hacer SI Huele GAS Instrucciones importante para la instalación Instrucciones DE Conexión a TierraSe colapsan o bloquean durante el uso o la instalación Instrucciones importante para Conectar LA Electricidad Guarde Estas InstruccionesTambor de acero inoXidable de CaPacidad SuPerior iluminado CaracTerÍSTicaS eSPecialeSPanel de conTrol Fácil Para uSar PuerTa reverSible de Fácil acceSoEstante de secado Piezas Y Componentes ClaveFiltro DE Pelusa Montado AL Frente Patas niveladorasESPacioS de inSTalaciÓn EScoJa el lugar adecuadoKit de apilado Dimensiones requeridas para La instalación con pedestalAccesorios Opcionales CÓmo inverTir el SenTido de la PuerTa NivelaciÓn de la Secadora WADVERTENCIAOpción 2 Ventilación inferior Opción 1 Ventilación lateralConeXiÓn del conducTo de venTilaciÓn de la Secadora Incorrecta Sistema de conductoCorrecta Requisitos eléctricos para modelos a gas únicamente ConeXiÓn de SecadoraS a gaSInstalaciones en lugares de gran altitud Conexión del suministro de gasConexión eléctrica Requisitos eléctricos únicamente para modelos eléctricos CÓmo conecTar laS SecadoraS elÉcTricaSWADVERTENCIA SÓlo ee.uu WADVERTENCIA 5 cm Revisión del nivelado Revisión DE Instalación FinalComprobación del calentamiento de la secadora Revisión del flujo de aireVentilación Correcta Flujo de Aire Restringido o Bloqueado Para activar el ciclo de evaluación del estado del conductoEtiquetas de mantenimiento de las telas Clasificación DE CargasCómo Cargar la secadora Revise EL Filtro DE Pelusa Antes DE Cada USOCaracterísticas DEL Panel DE Control Ciclos de Secado Manual Manual DRY Guía DE CiclosCiclos de Secado CON Sensor Sensor DRY La PanTalla GuÍa de cicloSFuncionamiento DE LA Secadora ConTrol del TemPeraTura TemP. conTrol Alarma beePerBoToneS de aJuSTe de cicloS Nivel de Secado drY levelPara instalar el estante de secado Botones DE Opción DE CicloPara añadir opciones de ciclo al ciclo Para recuperar un programa personalizado FuncioneS eSPecialeS Programa PerSonaliZadoCerradura a Prueba de niÑoS cHild locK Para guardar un programa personalizadoLimpieza alrededor y debajo de la secadora Limpieza RegularLimpieza del exterior Limpieza del filtro de pelusa Limpieza del interiorAnTeS de llamar a manTenimienTo Problema Causas posibles SolucionesEl tiempo de Kit de Apilado Color Herramientas necesarias para la instalación Instalación del pedestalEl accesorio de pedestal incluye Para Piso Cómo usar las almohadillasInstalación DEL KIT DE Apilado InSTalaciÓn del KiT de aPilado DimenSioneS Y eSPeciFicacioneS claveInformación de registro del producto Modèle Numéro de série Date d’achat Information relative à l’enregistrement du produitPrécautions de sécurité de base Lisez Toutes LES Directives Avant D’UTILISER L’APPAREILCE QU’IL Faut Faire SI Vous Détectez UNE Odeur DE GAZ Instructions DE Mise À LA Terre Précautions de sécurité Pour L’INSTALLATIONPrécautions de sécurité pour L’instaLLation suite Conservez CES Directives Porte réVersibLe À accÈs FaciLe Panneau de coMMande conViViaLCaractéristiQues spéciaLes Pieds de nivellement Dos de la sécheuse Accessoires comprisComposantes ET Pièces Principales Filtre À Charpie EN FaçadeDéGaGeMents CHoisir Le bon eMpLaceMentPiédestal Trousse d’empilage Vendu séparément Accessoires EN OptionInVersion de L’osciLLation de La porte Mise À niVeau de La sécHeuse waVertisseMentOption 2 Sortie d’air inférieure WAVERTISSEMENTOption 1 Sortie d’air latérale VentiLation de La sécHeuse Acheminement et raccord du système d’évacuation d’air Ventilation DE LA Sécheuse suiteSystème d’évacuation d’air RaccordeMent des sécHeuses À Gaz Branchement électrique Installations en haute altitudeRaccordement des sécheuses à gaz suite Raccordement de l’alimentation en gazMobiles ou préfabriquées de même que Toutes installations dans les maisonsRaccordeMent des sécHeuses éLectriQues Une connexion à 4 fils est exigée pourVérification du niveau Vérification Finale DE L’INSTALLATIONEssai du module de chauffage de la sécheuse Vérification du débit d’airCirculation d’air correcte Circulation d’air bloquée ÉVaLuation de L’état du conduit d’éVacuationÉtiquettes d’entretien des tissus Triage DES BrasséesChargement de la sécheuse Vérification DU Filtre À Charpie Avant Tout LA BrasséeCaractéristiques DU Panneau DE Commande De tissu Guide DE CycleAFFicHeur Guide de cYcLe suiteFonctionnement DE LA Sécheuse Bouton tiMe drY séchage programmé Boutons de réGLaGe du cYcLeBouton drY LeVeL niveau de séchage Bouton teMp. controL contrôle de la températureBouton DE Options DE Cycle Sauvegarde d’un programme personnalisé Fonctions spéciaLes Autres FonctionsCustoM proGraM programmation personnalisée CHiLd LocK verrouillage pour enfantsNettoyage Régulier Problèmes Causes possibles Solutions AVant d’appeLer Le serViceProblème Causes possibles Solutions Avant D’APPELER LE Service suiteTrousse De support Couleur Piédestal Trousse d’empilagePiédestal De 14 po Couleur Outils requis pour l’installation Installation du piédestalLe piédestal accessoire comprend InstaLLation du piédestaL suite La trousse d’empilage comprend Installation de la trousse d’empilageSpécifications ET Dimensions Principales Installation DE LA Trousse D’EMPILAGE suite119