GSI Outdoors PNEG-552 service manual Regulations, Decal DC-973

Page 11

2. Safety Alert Decals

Decal: DC-973

Decal DC-973 is located on the rear plenum access door (inside and outside).

Automatic equipment can start at anytime. Do not enter until fuel is shut off and electrical power is locked in off position. Failure to do so will result in serious injury or death.

 

 

 

 

DC-973

 

 

 

 

 

 

 

 

 

 

 

 

Decal: DC-338

3/4" MINIMUM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Decal DC-388 is located on the

 

 

 

 

 

 

 

 

BOLT DIAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hitch pin must be

hitch tongue.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

securely fastened and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

no less than 3/4" in

 

 

 

 

 

 

 

 

 

 

diameter. Failure to

 

 

 

 

 

 

 

 

 

 

 

-17"

 

 

 

 

 

follow installation

 

16

 

 

 

 

 

instructions may result

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in property damage.

 

 

 

 

 

 

 

 

 

 

 

 

DC-388

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HUB TEMPERATURE

 

 

 

 

Decal: DC-1249

 

 

 

 

 

 

 

NO GREATER THAN 150°F

TIGHTEN TO

 

Decal DC-1249 is located on

 

 

 

 

 

 

150°

 

 

90FT-LBS.

Dryer must be

 

 

 

 

 

the hitch tongue.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

towed empty and

 

 

 

 

 

 

 

in accordance

 

 

 

 

 

 

55-60 PSI

with state and

 

 

 

 

 

 

COLD

provincial

 

 

 

 

 

 

 

 

0

50

100

150

200

250

regulations.

 

CHECK AFTER 50 MILES AND EVERY 200 MILES

DC-1294

 

PNEG-552100 Series Dryer

 

 

11

Image 11
Contents Series Dryer PNEG-552100 Series Dryer Contents Table of Contents Safety Guidelines Emergency Stop Dryer OperationUse Caution in the Operation of this Equipment Safety PrecautionsDecal DC-889 Decal DC-1224Decal DC-972 Safety Alert DecalsDecal DC-1229 Decal DC-1227Decal DC-1225 Decal DC-973 RegulationsDryer Control Panel Moisture Control Dryer Control Panel Featuring the 100 Series Control SystemUnload Switch Dryer Power Stop Switch Setting the Dry, Cool, Unload and Out of Grain Timers Monitoring Grain Temperatures, Plenum Temperature or Timers Safety Circuit Shut Down Messages Special FeaturesLoss of Flame Error Conditions Error Conditions Inspect the Metering Rolls Set Control SwitchesFuel Check Electrical PowerControl Power Switch Power Start ButtonMetering Roll Operation Fan SwitchLP Gas Natural Gas Burner SafetyHeater Test Fire Staged Batch CheckRef # Description Dryer Shut DownStopping Dryer Operation Filling the Dryer Continuous Flow OperationFull Start-Up Check Staged Batch Operation Fan Setting Heater Setting Fan Function Heater FunctionPNEG-552 100 Series Dryer Starting the Dryer Series Batch Timer SettingsAdjusting the Temperature Full Heat Continuous Flow Operation Moisture % Removed pts Speed Dry Time min Low High Adjusting the Moisture ControlInitial Moisture Full Heat Approximate Hours of Service per Year Range Suggested Lube Interval Seasonal Inspection and ServiceInsulation Class Consistency Type Grease Frame Type Lubrication ProceduresSuggested Lubricants Additional ChecksRef # Description Clearance Holes Fan Propeller Removal and InstallationThreaded Bushing Holes Fan Blade Removal Fan Motor Removal and InstallationPosition of Fan Motor Heater Parts Removal and Installation Main Controls Metering Roll ServicingAs necessary. See F How to Determine a Metering Roll ProblemHow to Clear a Jammed Metering Roll Series Single Fan Wiring to Control Box Series Front Panel External Wiring Series Front Panel Internal Wiring Series Lower Back Panel Wiring Series External Wiring to Dryer Series Upper Control Box Wiring Series Main Power Wiring Series Control Schematic Series Control Schematic PNEG-552 100 Series Dryer Series 220 Volt 1 Phase Power Schematic Series 220VAC 3 Phase Power Schematic Series 440VAC 3 Phase Power Schematic Display shows Vapor High Temperature Problem Possible CausePress the dryer power start button Display shows Rear Discharge Warning Display shows Plenum High TemperatureDisplay shows Grain High Temperature Plenum High Temperature messages atTroubleshooting Wires connected together, the thermostat is faulty FAQs PNEG-552100 Series Dryer GSI Group Warranty